Diagnostic aids3-21 7510 Go Back Previous Next •Maintenance Count Resets •NV Resets and various types of JFFS@ partition formats Touch EVENT LOG from the Diagnostics Menu, and the following options are displayed: Display Log Print Log Clear Log Display the Event Log Note: The displayed version of the Event Log shows only a subset of the information contained in the Diagnostics version of the printed Event Log. For the most comprehensive information about each logged event, print the Event Log. See...
Page 402
3-22Service Manual 7510 Go Back Previous Next Print the Event Log Each page of the printed Event Log report has the title Event Log at the top of each page followed by the model name and serial number. The following is a sample of a printed Event Log: As the Event Log report prints, Printing EVENT LOG appears on the LCD. Clear the Event Log To clear the Event Log: 1. Touch Event Log from the Diagnostics Menu. 2. Touch Clear Log. Yes and No appears on the menu. If you touch Yes, Deleting EVENT LOG...
Page 403
Diagnostic aids3-23 7510 Go Back Previous Next SCANNER TESTS ASIC Test This operation performs a diagnostic test on the scanner ASIC that cycles through all of the scanner ASICs memory. To perform the ASIC Test: 1. Touch SCANNER TESTS from the Diagnostics Menu. 2. Touch ASIC Test. During this test, ASIC Test Running... appears on the LCD. At the completion of this test, ASIC Test Passed or ASIC Test Failed appears on the LCD. To clear the message, press Stop . Feed Test This test continuously executes...
Page 404
3-24Service Manual 7510 Go Back Previous Next Scanner Manual Registration Note: All scanner and ADF manual registration alignment verifications must be done in standard user mode, not in configuration or diagnostic mode. Note: You should verify the printer registration alignment before conducting the manual scanner registration process. For more information regarding printer registration, see “ENGINE ADJUST” on page 3-26. You can adjust the devices scanner and ADF registration through a manual...
Page 405
Diagnostic aids3-25 7510 Go Back Previous Next Trans Belt HP Fail Clear To perform the Trans Belt Fail Clear Test: 1. Touch Trans Belt Fail Clear from the Diagnostics Menu. 2. Touch Trans Belt HP Fail Clear. Trans Belt HP Fail Clear Testing.... appears on the LCD. Press Stop to return to Trans Blet PH Fail Clear. Dev Unit Reset To perform the Dev Unit Reset Test: 1. Touch Dev Unit Reset from the Diagnostics Menu. The following tests appear on the LCD: When each test completes, the LCD returns to Dev...
Page 406
3-26Service Manual 7510 Go Back Previous Next ENGINE ADJUST To begin PH Adjust (media tray registration), the test page must be printed. To print the test page the printer must be in standard mode. 1. Select Menus. 2. Select Reports. 3. Select Network Setup Page The following report prints. Using a fine incremental ruler, measure from the black line border to the edge of the media. Ideally, the borders should be centered on the page. To perform the ENGINE ADJUST settings: 1. Select ENGINE ADJUST from...
Page 407
Diagnostic aids3-27 7510 Go Back Previous Next Adj Lead Reg ALL (appears on LCD) (Adj lead reg all trays)Registration values appear on the LCD. If required, reset the values and Select to submit the changes. Adj Lead Reg Tr165 (appears on LCD) (Adj lead reg tray 1 - plain/color)Registration values appear on the LCD. If required, reset the values and Select to submit the changes. Adj Lead Reg MSI165 (appears on LCD) (Adj lead reg MPF - plain/color)Registration values appear on the LCD. If required,...
Page 408
3-28Service Manual 7510 Go Back Previous Next Press Stop to return to ENGINE ADJUST. PRO-CON (ATC sensor setup and adjust) This procedure is used to adjust the following: Sensor (C ATC) Sensor (M ATC) Sensor (Y ATC) Sensor (K ATC) Select PRO-CON and select: Then Select: Appears on the LCD ATC Sensor Adjust values (Sen Grad SNR-Y Registration values appear on the LCD. If required, reset the values and Select to submit the changes. Sen Grad SNR-M Registration values appear on the LCD. If required,...
Page 409
Diagnostic aids3-29 7510 Go Back Previous Next Color registration (RegCon) The purpose of the color registration is to establish correct horizontal and vertical positioning of the four primary color images. The procedure consists of the following steps, which must be performed in the listed sequence: 1.Belt Edge Learn - Used to align the transfer belt positioning system. 2.Fine Skew Setup - Automatically performs horizontal and vertical alignment, and reports any skew in the various images caused by...
Page 410
3-30Service Manual 7510 Go Back Previous Next Testing the manual scanner registration Note: Machine must be in Standard User Mode. To properly position the Network Setup Page which will be used as the ADF test original page on the flatbed scanner and the ADF side 1 and ADF side 2, follow the graphic below: Warning: Ensure that the Network Setup Page is properly positioned according to the diagrams, or registration and margins cannot be properly adjusted. 1. Place the Network Setup Page on the flatbed...