Page 71
Diagnostic Error Code FRU/Action 015-036-XXX USB port Register error System board 015-040-XXX USB port IRQ failure 1. Run setup and check for conflicts 2. Flash the system. See “Flash update procedures” on page 207 3. System board 015-195-XXX USB port Test aborted by user Information only Re-start the test, if necessary 015-196-XXX USB port test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 015-197-XXX USB...
Page 72
Diagnostic Error Code FRU/Action 018-197-XXX PCI Card test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 018-198-XXX PCI Card test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51...
Page 73
Diagnostic Error Code FRU/Action 020-198-XXX PCI test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 020-199-XXX PCI test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3....
Page 74
Diagnostic Error Code FRU/Action 025-198-XXX IDE interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 025-199-XXX IDE interface test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update...
Page 75
Diagnostic Error Code FRU/Action 030-198-XXX SCSI interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 030-199-XXX SCSI interface test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update...
Page 76
Diagnostic Error Code FRU/Action 071-00X-XXX 071-01X-XXX 071-02X-XXX Audio port error 1. Run Setup 2. Flash the system. See “Flash update procedures” on page 207 3. System board 071-03X-XXX Audio port failure 1. Speakers 2. Microphone 3. Audio card, if installed 4. System board 071-04X-XXX Audio port failure 1. Run Setup 2. Audio card, if installed 3. System board 071-195-XXX Audio port Test aborted by user Information only Re-start the test,...
Page 77
Diagnostic Error Code FRU/Action 080-196-XXX Game Port interface test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 080-197-XXX Game Port interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test...
Page 78
Diagnostic Error Code FRU/Action 086-197-XXX Mouse Port interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 086-198-XXX Mouse Port interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup...
Page 79
Diagnostic Error Code FRU/Action 170-0XX-XXX Voltage Sensor(s) failure 1. Flash system 2. System board 170-195-XXX Voltage Sensor(s) Test aborted by user Information only Re-start the test, if necessary 170-196-XXX Voltage Sensor(s) test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 170-197-XXX Voltage Sensor(s) test warning 1. Make sure the component that is called out is connected and/or enabled. See...
Page 80
Diagnostic Error Code FRU/Action 175-197-XXX Thermal Sensor(s) test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 175-198-XXX Thermal Sensor(s) test aborted 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test....