Page 91
TS-2000/X PARTS LIST 91K : TS-2000 (K) KX : TS-2000X (K) E : TS-2000 (E) E2 : TS-2000 (E2) Ref. No.AddressParts No. Description Ref. No.AddressParts No. DescriptionNewDesti-partsnationNewDesti-partsnation R44 RK73EB2B560J CHIP R 56 J 1/8W R45 RK73GB1J182J CHIP R 1.8K J 1/16W R46 RK73GB1J103J CHIP R 10K J 1/16W R47 RK73GB1J182J CHIP R 1.8K J 1/16W R48 RK73GB1J103J CHIP R 10K J 1/16W R49 RK73EB2B560J CHIP R 56 J 1/8W R50 R92-0700-05 CHIP R 180 J 1/2W R51 RK73GB1J101J CHIP R 100 J 1/16W R52 RK73GB1J821J...
Page 92
TS-2000/X PARTS LIST 92K : TS-2000 (K) KX : TS-2000X (K) E : TS-2000 (E) E2 : TS-2000 (E2) Ref. No.AddressParts No. Description Ref. No.AddressParts No. DescriptionNewDesti-partsnationNewDesti-partsnation R376 RK73GB1J153J CHIP R 15K J 1/16W R377 RK73GB1J682J CHIP R 6.8K J 1/16W R378 RK73GB1J151J CHIP R 150 J 1/16W R379 RK73GB1J101J CHIP R 100 J 1/16W R381 R92-1252-05 CHIP R 0 OHM R383 RK73GB1J102J CHIP R 1.0K J 1/16W R384 RK73GB1J470J CHIP R 47 J 1/16W R385,386 RK73GB1J103J CHIP R 10K J 1/16W VR1...
Page 93
TS-2000/X TS-2000/X 9394 AC BD 1 2 3 1 2 3 112x2 112x2 86 86 86 Ex2 Ex2 120 75 81 101 70 31 33 53 28 Mx10 139 100 Mx2 Kx2 61 35 34 114x2 Fx2 113x2 111 F F 103102 30 32 27 Ex2 Ex4 72 69 97 88x2 27 29 Gx2 Gx2 Ex2 Ex2 Mx5 Control 89x219 50 19 20 25x2 25x2 19 67 68x3 17 Mx2 Mx2 Mx2 Mx2 Bx2H 73 Mx4Mx6 71 Filter TX-RX3Mx9 Mx13 Final (A/2) 4 79 Mx2 Mx2Final (B/2) Mx8Jx3 Jx2Kx2 TX-RX2(A/11) TX-RX2 (B/11) TX-RX2 (C/11) Mx13Mx7 Mx6 115 511 Mx2 Lx17 TX-RX1 (A/9) R x10 P x2 504 506 6254501 512 83 76 401 402 x5...
Page 94
95 TS-2000/X E F 1 2 3 8 18 126121 C 80 85x2 128x2 N 127x284x2 78x3130x3 129x3122 123 110 124125 82 98 146x214255 27 92 93 91 95 96 94x3 TX-RX1 (B/9) Mx3 1165 87 202 201 203 207 205 212 99 6 208x5204x6 TX-RX1 (G/9) TX-RX1 (F/9)TX-RX1 (C/9) TX-RX1 (D/9) TX-RX1 (E/9) 143 D A : N14-0569-04 C : N19-0670-05 D : N19-0673-05 L M2.6 x 6 (Br-Tap) : N87-2606-46 M M2.6 x 8 (Br-Tap) : N87-2608-46 N M3 x 8 (TP) : N90-3008-46 Lx2 Lx2 Ax2 211 117 Display 108 CN801 CN1 CN800 CN805 CN806CN952 CN953 EXPLODED VIEW (FRONT...
Page 95
96 TS-2000/X G H 1 2 3 8 1 8 1 20 1 12 1 12 1 1 1 1 1 2 2 3 3 4 4 5 5 G13-1869-05 G13-1870-05 G13-1871-05 F12-0463-04 G13-1872-05PCB Attach to the foil side of PCB 104 105 106 107 74 EXPLODED VIEW (CUSHION) Parts with the exploded numbers larger than 700 are not supplied.
Page 96
97 TS-2000/X I J 1 2 3 12 Warranty card (B46-0310-03) : E,E2 (B46-0469-10) : K,KX 13 Schematic diagram (B52-0614-00) 14 Schematic diagram (B52-0616-00) 15 Schematic diagram (B52-0617-00) 27 Schematic diagram (B52-0618-00) 28 Pamphlet (B59-1777-00) : E,E2 16 Instruction manual (B62-1221-00) : K,KX,E (B62-1222-00) : E (B62-1223-00) : E2 (B62-1224-00) : E (B62-1225-00) : E (B62-1226-00) : E Polystyrene foamed fixture...
Page 97
98 TS-2000/X Required Test Equipment 1. DC Voltmeter (DC V.M) 1) Input resistance : More than 1MΩ 2) Voltage range : 1.5 to 1000V AC/DC Note : A high-recision multimeter may be used. How- ever, accurate readings can not be obtained for high- impedance circuits. 2. DC Ammeter 1) Current range : 100mA, 1.5A, 15A, high-precision am- meter may be used. 3. RF VTVM (RF V.M) 1) Input impedance : 1MΩ and less than 3pF, min. 2) Voltage range : 10mV to 300V 3) Frequency range : 10kHz to 500MHz 4. AF Voltmeter (AF...
Page 98
99 TS-2000/X Preparation Unless otherwise specified, knobs and switches should be set as follows. POWER ........................................................................... ON MANUAL BC ............................................................... Center MAIN RF GAIN ............................................................ MAX MAIN AF GAIN .............................................................. MIN NAIN SQL ..................................................................... MIN...
Page 99
100 TS-2000/X CN49 CN18 CN10 CN1 B. Flat cable (16P) (E37-0572-05) About 17cm A. Lead wire with minipin plug (E37-0878-05) About 56cm Service Jig How to use ADJUSTMENT A. Lead wire with minipin plug B. Flat cable (16P) Adjustment Mode Outline 1. The TS-2000/X can be adjusted manually (by turning a coil, trimmer, etc.) or by setting the service adjustment mode (adjustment with panel keys). In the service ad- justment mode (simply referred to as the adjustment mode below), adjustments...
Page 100
101 TS-2000/X CN24S1ON OFF Adjustment Mode Menu (Menu No. 00~126) No. Adjustment item ItemFrequencyMode 00 ALC reference voltage 14.1M 14.1M USB 01146M BPF center voltage (Main)146M 145.99M USB 02 Variable capacitor voltage 142M 142.00M USB 03 Variable capacitor voltage 144M 144.00M USB 04 Variable capacitor voltage 148M 148.10M USB 05 Variable capacitor voltage 152M 151.90M USB 06435M BPF center voltage (Main)440M 440.00M USB 07 Variable capacitor voltage 450M 449.80M USB 08 Variable capacitor voltage...