Page 91

TS-2000/X
PARTS LIST
91K : TS-2000 (K) KX : TS-2000X (K)
E : TS-2000 (E) E2 : TS-2000 (E2)
Ref. No.AddressParts No. Description Ref. No.AddressParts No. DescriptionNewDesti-partsnationNewDesti-partsnation
R44 RK73EB2B560J CHIP R 56 J 1/8W
R45 RK73GB1J182J CHIP R 1.8K J 1/16W
R46 RK73GB1J103J CHIP R 10K J 1/16W
R47 RK73GB1J182J CHIP R 1.8K J 1/16W
R48 RK73GB1J103J CHIP R 10K J 1/16W
R49 RK73EB2B560J CHIP R 56 J 1/8W
R50 R92-0700-05 CHIP R 180 J 1/2W
R51 RK73GB1J101J CHIP R 100 J 1/16W
R52 RK73GB1J821J...

Page 92

TS-2000/X
PARTS LIST
92K : TS-2000 (K) KX : TS-2000X (K)
E : TS-2000 (E) E2 : TS-2000 (E2)
Ref. No.AddressParts No. Description Ref. No.AddressParts No. DescriptionNewDesti-partsnationNewDesti-partsnation
R376 RK73GB1J153J CHIP R 15K J 1/16W
R377 RK73GB1J682J CHIP R 6.8K J 1/16W
R378 RK73GB1J151J CHIP R 150 J 1/16W
R379 RK73GB1J101J CHIP R 100 J 1/16W
R381 R92-1252-05 CHIP R 0 OHM
R383 RK73GB1J102J CHIP R 1.0K J 1/16W
R384 RK73GB1J470J CHIP R 47 J 1/16W
R385,386 RK73GB1J103J CHIP R 10K J 1/16W
VR1...

Page 93

TS-2000/X TS-2000/X
9394
AC
BD
1
2
3
1
2 3 112x2
112x2 86
86 86
Ex2
Ex2
120
75 81
101
70
31
33
53
28
Mx10
139
100
Mx2
Kx2
61
35
34
114x2
Fx2
113x2
111
F F
103102
30 32 27
Ex2
Ex4
72
69
97
88x2 27
29
Gx2
Gx2
Ex2 Ex2
Mx5 Control
89x219 50
19 20
25x2
25x2
19
67 68x3
17
Mx2
Mx2
Mx2
Mx2
Bx2H
73
Mx4Mx6
71
Filter
TX-RX3Mx9
Mx13
Final (A/2)
4
79
Mx2
Mx2Final (B/2)
Mx8Jx3 Jx2Kx2
TX-RX2(A/11)
TX-RX2
(B/11)
TX-RX2
 
(C/11)
Mx13Mx7
Mx6
115
511
Mx2
Lx17 TX-RX1 (A/9)
R x10
P x2
504
506
6254501
512
83
76
401
402 x5...

Page 94

95
TS-2000/X
E
F
1
2
3
8
18
126121
C
80
85x2 128x2
N
127x284x2
78x3130x3
129x3122
123
110
124125 82
98 146x214255
27
92
93
91
95
96 94x3
TX-RX1
(B/9)
Mx3
1165
87
202
201
203
207
205
212
99
6 208x5204x6
TX-RX1
(G/9)
TX-RX1
(F/9)TX-RX1
(C/9)
TX-RX1
(D/9) TX-RX1
(E/9)
143
D A : N14-0569-04
C : N19-0670-05
D : N19-0673-05
L M2.6 x 6 (Br-Tap) : N87-2606-46
M M2.6 x 8 (Br-Tap) : N87-2608-46
N M3 x 8 (TP) : N90-3008-46
Lx2
Lx2 Ax2
211
117
Display
108
CN801 CN1
CN800
CN805
CN806CN952
CN953
EXPLODED VIEW (FRONT...

Page 95

96
TS-2000/X
G
H
1
2
3
8 1
8 1
20 1
12 1
12 1
1
1
1
1
2
2
3
3
4
4
5
5
G13-1869-05 G13-1870-05 G13-1871-05
F12-0463-04 G13-1872-05PCB
Attach to the foil 
side of PCB
104 105 106
107 74
EXPLODED VIEW (CUSHION)
Parts with the exploded numbers larger than 700 are not supplied. 

Page 96

97
TS-2000/X
I
J
1
2
3
12  Warranty card
      (B46-0310-03) : E,E2
      (B46-0469-10) : K,KX
13  Schematic diagram
      (B52-0614-00)
14  Schematic diagram
      (B52-0616-00)
15  Schematic diagram
      (B52-0617-00)
27  Schematic diagram
      (B52-0618-00)
28  Pamphlet
      (B59-1777-00) : E,E2
16  Instruction manual
      (B62-1221-00) : K,KX,E
      (B62-1222-00) : E
      (B62-1223-00) : E2
      (B62-1224-00) : E
      (B62-1225-00) : E
      (B62-1226-00) : E
Polystyrene foamed 
fixture...

Page 97

98
TS-2000/X
Required Test Equipment
1. DC Voltmeter (DC V.M)
1) Input resistance : More than 1MΩ
2) Voltage range : 1.5 to 1000V AC/DC
Note : A high-recision multimeter may be used.  How-
ever, accurate readings can not be obtained for high-
impedance circuits.
2. DC Ammeter
1) Current range : 100mA, 1.5A, 15A, high-precision am-
meter may be used.
3. RF VTVM (RF V.M)
1) Input impedance : 1MΩ and less than 3pF, min.
2) Voltage range : 10mV to 300V
3) Frequency range : 10kHz to 500MHz
4. AF Voltmeter (AF...

Page 98

99
TS-2000/X
Preparation
Unless otherwise specified, knobs and switches should
be set as follows.
POWER ...........................................................................  ON
MANUAL BC ............................................................... Center
MAIN RF GAIN ............................................................  MAX
MAIN AF GAIN .............................................................. MIN
NAIN SQL .....................................................................  MIN...

Page 99

100
TS-2000/X
CN49
CN18
CN10
CN1
B. Flat cable (16P)
    (E37-0572-05)
    About 17cm A. Lead wire with
minipin plug
    (E37-0878-05)
    About 56cm
Service Jig
How to use
ADJUSTMENT
A. Lead wire with minipin plug
B. Flat cable (16P)
Adjustment Mode
Outline
1. The TS-2000/X can be adjusted manually (by turning a
coil, trimmer, etc.) or by setting the service adjustment
mode (adjustment with panel keys).  In the service ad-
justment mode (simply referred to as the adjustment
mode below), adjustments...

Page 100

101
TS-2000/X
CN24S1ON OFF
Adjustment Mode Menu (Menu No. 00~126)
No. Adjustment item ItemFrequencyMode
00 ALC reference voltage 14.1M 14.1M USB
01146M BPF center voltage (Main)146M 145.99M USB
02 Variable capacitor voltage 142M 142.00M USB
03 Variable capacitor voltage 144M 144.00M USB
04 Variable capacitor voltage 148M 148.10M USB
05 Variable capacitor voltage 152M 151.90M USB
06435M BPF center voltage (Main)440M 440.00M USB
07 Variable capacitor voltage 450M 449.80M USB
08 Variable capacitor voltage...