Page 101
102 TS-2000/X No. Adjustment item ItemFrequencyMode 33 FM S-full scale FM full 50.2M FM 34 SSB IF gain SSB start 144.2M USB 35 SSB S1 SSB S1 144.2M USB 36 SSB S9 SSB S9 144.2M USB 37 SSB S-full scale SSB S full 144.2M USB 38 FM S1 FM S1 145.8M FM 39 FM full scale FM full 145.8M FM 40 FM S1 (SUB) FM S1 145.8M FM 41 FM full scale (SUB) FM full 145.8M FM 42 AM S1 AM S1 120.2M AM 43 AM S-full scale AM full 120.2M AM 44 SSB IF gain SSB start 438.2M USB 45 SSB S1 SSB S1 438.2M USB 46 SSB S9 SSB S9 438.2M USB...
Page 102
103 ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item TS-2000/X Display Check 1. All reset 1) DC IN : 13.8V Front LCD After displaying Display should be normal. Hold down [A=B] key and panel “HELLO”, the Should be at the reset press the [POWER]key. display is reset as frequency. follows; Main band side DISP f. : 14.000.00 Mode : USB ANT1, PTT, CTRL, AGC, PRE Sub band side DISP f. : 144.000.00Mode : FM PRE, TNC 2. LCD all 1) Menu No. : 126...
Page 103
ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item 104 TS-2000/X 7) VHF MAIN PLL DC V.M TX-RX2 TP503 TX-RX2 TC405 1.0V±0.03V Display f. : 142.00MHz Spectrum (B/11) (H/11) Mode : FM analyzer Display f. : 152.000MHz Check 4.6V or less 8) UHF PLL TP504 TX-RX2 TC404 6.0V±0.05V Display f. : 449.990MHz (G/11) Mode : FM Display f. : 420.000MHz Check 1.5V or more 9) SUB1 PLL TX-RX2 TP506 TX-RX2 TC400 5.5V±0.2V Display f. : 154.495MHz (C/11) (K/11)...
Page 104
105 ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item TS-2000/X 3. MCF 1) Display f. : 14.000MHz Tracking Rear ANT1 TX-RX1 L54 Adjust the coils to (69.085MHz) Mode : USB generator panel (A/9) L62 obtain the frequency PRE-AMP : ON L63 response as shown. AGC : OFF Spectrum TX-RX1 TP4 L64 Spectrum analyzer setting analyzer (A/9) (CN6) L68 Center f. : 69.085MHz TP5 Frequency span : 100kHz (CN9) XdB/DIV : 10dB RBW : 30kHz VBW : 30kHz 4. MCF 1)...
Page 105
ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item 106 TS-2000/X 6. MAIN 1) Trap default Tracking Rear ANT430 TX-RX2 TC9 Adjust the trimmer UHF BPF generator panel (A/11) to get a null point at 366MHz as shown. Spectrum TX-RX2 CN19 analyzer (A/11) 2) Menu No. : 06 Front [+] key After setting the Display f. : 440MHz panel or adjustment value to Spectrum analyzer setting [–] key 145, adjust each Center f. : 440.000MHz TX-RX2 TC1 trimmer to...
Page 106
107 ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item TS-2000/X 10. 10.695MHz 1) Menu No. : 20 SSG1 Rear ANT2 Front [+] key Change the adjust- IF filter SSG1 f. : 1.8330MHz SSG2 pnel panel or ment values to get SSG1 output : –33dBm/5010µV2 signal pad[–] key the waveform as SSG2 f. : 1.8301MHz shown. SSG2 output : –33dBm/5010µVOscilloscopeTX-RX1 TP1 Disconnect the cable from (A/9) CN23. 11. 455kHz 1) Menu No. : 21 TP2 IF filter Connect the...
Page 107
ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item 108 TS-2000/X 17. Sub band 1) Menu No. : 10 SSG Rear ANT144 TX-RX2 L28 After setting the S-meter voltage max. BPF Display f. : 146MHz panel (A/11) L44 adjustment value to Mode : FM OscilloscopeEXT. SP L52 90, adjust each coilSSG output : –110dBm/0.707µVAF V.M to obtain the MOD : 1kHz DM. SP TX-RX2 SSM specified values. DEV : 3kHz (A/11) 2) Menu No. : 11 Front [+] key Change the adjust-...
Page 108
109 ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item TS-2000/X Band Frequency (K) Frequency (E) ModeSSG RF level (dBm)SSG MOD DEVMeasurementSpec. MAIN 550kHz 550KHz AM –85 1kHz60%→OFFS/N >10dB MAIN 14.200MHz 14.200MHz USB –119→OFF OFF OFF S/N >10dB MAIN 18.200MHz 18.200MHz USB –119→OFF OFF OFF S/N >10dB MAIN 52.200MHz 52.200MHz FM –118 1kHz 3kHz SINAD >12dB MAIN 146.200MHz 145.200MHz AM –106 1kHz60%→OFFS/N >10dB MAIN 146.200MHz 145.200MHz...
Page 109
ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item 110 TS-2000/X 24. 50MHz FM 1) Menu No. : 32 SSG Rear ANT1 Front [+] key 1 push S-meter lights up to S1 level. S-meter Display f. : 50.2MHz panel panel or S1 Mode : FM AF V.M EXT. SP [–] key SSG output : –117dBm/0.316µVOscilloscopeMOD : 1kHz DM. SP DEV : 3kHz Full scale 2) Menu No. : 33S-meter lights up all. (Lights up all)SSG output : –95dBm/3.98µV 25. 144MHz 1) Menu No. : 35 ANT144 S-meter...
Page 110
111 ADJUSTMENT Measurement Test- equipmentUnitTerminalAdjustment Unit Parts MethodSpecifications/Remarks Condition Item TS-2000/X 30. 440MHz 1) Menu No. : 48 SSG Rear ANT430 Front [+] key 1 push S-meter lights up to S1 level. FM S-meter Display f. : 438.2MHz panel panel or S1 Mode : FM AF V.M EXT. SP [–] key SSG output : –117dBm/0.316µVOscilloscopeMOD : 1kHz DM. SP DEV : 3kHz Full scale 2) Menu No. : 49S-meter lights up all. (Lights up all)SSG output : –95dBm/3.98µV 31. 440MHz 1) Menu No. : 50S-meter...