36 4RECEIVE AND TRANSMIT D D Contest number set mode This menu is used to set the contest (serial) number and count up trigger, etc. •Setting contents qSelect CW mode with [MODE]. wEnter the memory keyer menu. • Push[MODE] for 1 sec. to enter the memory keyer send menu. • Push [DISPLAY] momentarily to enter the memory keyer menu. ePush [(F-2)001] to enter the contest number set mode. rPush [MENU] once or twice to select the desired set item. • [M-CH] or [Y]/[Z] can also be used. tSet the desired condition using the main dial. yPush [DISPLAY] twice to return to the memory keyer send menu. [MENU][DISPLAY][M-CH][F-2] [MODE]Main dial [Y] [Z] 02 CONT UP TRIG(Count up trigger) This selects which of the three memory slots will have the contest serial number exchange. The count up trigger allows the serial number automatically incre- mented after each complete serial number exchange is sent. • 1 (MK1), 2 (MK2) and 3 (MK3) can be set. (default: 2) CW 02 CNT UP TRIG 01 NUM STYLE(Number style) This item sets the numbering system used for contest (serial) numbers— normal or morse cut numbers. n : Does not use morse cut number (default) 190.Ano : Sets 1 as A, 9 as N and 0 as O. 190.Ant : Sets 1 as A, 9 as N and 0 as T. 90.no : Sets 9 as N and 0 as O. 90.nt : Sets 9 as N and 0 as T.CW 01 NUM STYLE 03 PRESENT No.(Present number) This item shows the current number for the count up trigger channel set above. • Rotate the tuning dial to change the number. CW 03 PRESENT No. 4
37 4RECEIVE AND TRANSMIT D D Memory keyer set mode This set mode is used to set the memory keyer repeat time and indication type of the messages. •Setting contents qSelect CW mode with [MODE]. wEnter the memory keyer menu. • Push[MODE] for 1 sec. to enter the memory keyer send menu. • Push [DISPLAY] momentarily to enter the memory keyer menu. ePush [(F-3)SET] to enter the memory keyer set mode. rPush [MENU] to select the desired set item. • [M-CH] or [Y]/[Z] can also be used. tSet the desired condition using the main dial. yPush [DISPLAY] twice to return to the memory keyer send menu. [MENU][DISPLAY][M-CH][F-3] [MODE]Main dial [Y] [Z] 01 REPEAT TIME(Repeat time) When sending CW using the repeat timer, this item sets the time between transmission. • 1 to 60 sec. in 1 sec. steps can be selected. CW 01 REPEAT TIME 02 MSG DISPLAY(Message display) This item sets the indication type of the messages (pre-set characters). n : Normal indication (default) [ (F-1)MK1], [(F-2)MK2], [(F-3)MK3] 3 : First three characters of the massages are in- dicated. e.g. [ (F-1)CQ ], [(F-2)UR ], [(F-3)CFM] 3.cn : First three characters of the massages and contest number are indicated. e.g. [ (F-1)CQ ], [(F-2)001], [(F-3)CFM] CW 02 MSG DISPLAY
38 4RECEIVE AND TRANSMIT DConnections for RTTY (FSK) 4 8 12 [ACC] 1 2 3 76 5 9 10 11 13 Rear panel TU or TNC Personal computer Rear panel view Colors refer to connection to the supplied ACC cable.* 1Connect SQL line when required. MSEND (orenge) GND (red) FSKK (black) SQL* 1 (light green) AF out (light blue) Operating RTTY DRTTY (FSK) operation qConnect a terminal unit as at above. wPush [ (Y)BAND]/[(Z)BAND] to select the desired band. ePush [MODE] momentarily to select RTTY mode. • After RTTY mode is selected, push [MODE] for 1 sec. to toggle between RTTY and SSB-D modes. rWhile the quick set mode item “Q2” is selected in RTTY mode, rotate main dial to select RTTY or åRTTY mode. • Push [DISPLAY] for 1 sec. to enter the quick set mode. • Push [MENU] one or more times to select Q2. • Push [DISPLAY] momentarily to return to normal oper- ating mode. tRotate [AF] to set audio to a comfortable listening level. ySelect the desired FSK tone/shift frequencies and keying polarity as at page 40. uRotate the main dial to tune a desired signal. • Use [(F-1)1/4] in the M4display when critical setting is required. •S-meter indicates received signal strength. •If the received signal cannot be demodulated, try se- lecting åRTTY mode (or RTTY mode). iTransmit a SEND signal from your TNC. •The TX indicator lights red. •T he Po meter indicates transmitted RTTY signal strength. oOperate the connected PC or TNC (TU) to trans- mit RTTY (FSK) signals. RLSB CH VFO APO S1 5 5 379 20 40 10 60dB USB CWRTTYAM WFM M4 1/4 TON AGC [TX] indicator [MODE]Main dial [DISPLAY] [F-1] [MENU] [F-2] [AF] [Y] [Z] “RTTY” or “åRTTY” appears 4
39 4RECEIVE AND TRANSMIT •Preamp and attenuator(p. 46) ➥Push [P.AMP/ATT] momentarily to set the preamp ON or OFF. • Lights green when the preamp is set to ON. ➥Push [P.AMP/ATT] for 1 sec. to set the attenuator ON. • Push [P.AMP/ATT] momentarily to turn the attenua- tor OFF. • Lights red when the attenuator is set to ON. •Noise blanker(p. 48) ➥While “M3” is selected, push [ (F-2)NB] to turn the noise blanker ON and OFF. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M3. • “NB” appears when the noise blanker is set to ON. • Push [ (F-2)NB] for 1 sec. to enter the noise blanker set mode. •AGC (auto gain control)(p. 48) ➥While “M4” is selected, push [ (F-3)AGC] to select AGC fast and AGC slow. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. •“F AGC” appears when the fast time constant is se- lected. •IF shift(p. 47) ➥Rotate [SHIFT] control. •Noise reduction(p. 50) ➥While “S4” is selected, push [(F-2)NR] to turn the noise reduction ON and OFF. • Push [DISPLAY] once or twice to select S. • Push [MENU] one or more times to select S4. • Push [(F-3)NRL] then rotate [M-CH] to adjust the noise reduction level. • “NR” appears when the noise reduction is set to ON. •Auto notch filter(p. 50) ➥While “S4” is selected, push [(F-1)ANF] to turn the auto notch filter function ON and OFF. • “ANF” appears when the noise reduction is set to ON. •1⁄4function ➥While “M4” is selected, push [ (F-1)1/4] to turn the 1⁄4function ON and OFF. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. DConvenient functions for receive DRTTY reverse mode Received characters are occasionally garbled when the receive signal is reversed between MARK and SPACE. This reversal can be caused by incorrect TNC connections, settings, commands, etc. To receive a reversed RTTY signal correctly, select åRTTY (RTTY reverse) mode. qSelect RTTY mode with [MODE]. w Push [DISPLAY] for 1 sec. to enter quick set mode. ePush [MENU] one or more times to select “Q2 RTTY REV,” then rotate the main dial to select RTTY and åRTTY modes. • Check the interference tone. rPush [DISPLAY] momentarily to exit quick set mode. Reverse Normal BFO 170 Hz2125 Hz170 Hz 2125 Hz BFOMark Space displayed freq. displayed freq.Mark Space [MODE] Main dial [DISPLAY] [MENU] QUICK SET MODE
40 4RECEIVE AND TRANSMIT DPresetting for RTTY Tone frequency qPush [MODE] momentarily to select RTTY mode. • After RTTY mode is selected, push [MODE] for 1 sec. to toggle between RTTY and SSB-D modes. wEnter the RTTY tone set mode. •Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. • Push [ (F-2)TON] for 1 sec. to enter the RTTY tone set mode (below). ePush [MENU] one or more times to select “R1 RTTY TONE,” then rotate the main dial to select the desired frequency. Shift frequency qEnter the RTTY tone set mode as same as above. wPush [MENU] one or more times to select “R2 RTTY SHIFT,” then rotate the main dial to select the desired shift frequency. RTTY keying qEnter the RTTY tone set mode as same as above. wPush [MENU] one or more times to select R3 RTTY KEYING; then rotate the main dial to se- lect the desired keying polarity. After presetting is finished, push [DISPLAY] momen- tarily to return the normal operating mode. RTTY R3RTTY KEYING RTTY keying is set to ‘normal’. normal : key open=mark key close=space reverse: key open=space key close=mark RTTY R2RTTY SHIFT RTTY shift frequency is set to 170 Hz. 170/200/425 Hz are available. RTTY R1RTTY TONE RTTY mark frequency is set to 2125 Hz. 2125, 1615 and 1275 Hz are available. [MODE]Main dial [DISPLAY] [MENU] [F-2] R3 RTTY KEYING (RTTY only) This item adjusts the RTTY keying. Normal or reverse keying can be selected. The default is “n,” normal.Normal : key open=mark Reverse : key open=space RTTY R1 RTTY TONE This item selects the RTTY tone. RTTY tone is se- lected between 1275, 1615 and 2125 Hz. The default is 2125 Hz. RTTY R2 RTTY SHIFT This item adjusts the RTTY shift. There are 3 selec- table values: 170, 200 and 425 Hz. The default is 170 Hz. RTTY While M4is selected in RTTY mode, push [(F-2)TON] for 1 sec. to enter the RTTY tone set mode. DRTTY tone set mode 4
41 4RECEIVE AND TRANSMIT DConvenient functions for receive DConvenient functions for transmit Operating AM qPush [(Y)BAND]/[(Z)BAND] to select the desired band. wPush [MODE] momentarily or push for 1 sec. to se- lect AM mode. • After FM or AM mode is selected, push [MODE] for 1 sec. to toggle between FM and AM modes. eRotate [AF] control to set audio to a comfortable lis- tening level. rRotate the main dial to tune a desired signal. • S-meter indicates received signal strength. • The default tuning step for AM mode is 1 kHz; this can be changed using the tuning step program mode. (p.19) tPush [PTT] (microphone) to transmit. • The TX indicator lights red. ySpeak into the microphone at your normal voice level. • Adjust ‘MIC GAIN’ at this step, if necessary. (p. 26) uRelease [PTT] (microphone) to return to receive. RLSB CH VFO APO S1 5 5 379 20 40 10 60dB USB CW RTTYAMWFM M1 SPL A/B XFC [TX] indicator [MODE] Main dial [AF] [Y] [Z] “AM” appears •Preamp and attenuator(p. 46) ➥Push [P.AMP/ATT] momentarily to set the preamp ON or OFF. • Lights green when the preamp is set to ON. ➥Push [P.AMP/ATT] for 1 sec. to set the attenuator ON. • Push [P.AMP/ATT] momentarily to turn the attenua- tor OFF. • Lights red when the attenuator is set to ON. •Noise blanker(p. 48) ➥While “M3” is selected, push [ (F-2)NB] to turn the noise blanker ON and OFF. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M3. • “NB” appears when the noise blanker is set to ON. • Push [ (F-2)NB] for 1 sec. to enter the noise blanker set mode. •Initial set mode item “30 AM NB” (p. 80) is must be set ON when noise blanker function is used in AM mode. (Default setting is ON.) •IF shift(p. 47) ➥Rotate [SHIFT] control.•AGC (auto gain control)(p. 48) ➥While “M4” is selected, push [ (F-3)AGC] to select AGC fast and AGC slow. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. •“F AGC” appears when the fast time constant is se- lected. •Noise reduction(p. 50) ➥While “S4” is selected, push [(F-2)NR] to turn the noise reduction ON and OFF. • Push [DISPLAY] once or twice to select S. • Push [MENU] one or more times to select S4. • Push [(F-3)NRL] then rotate [M-CH] to adjust the noise reduction level. • “NR” appears when the noise reduction is set to ON. •Auto notch filter(p. 50) ➥While “S4” is selected, push [(F-1)ANF] to turn the auto notch filter function ON and OFF. • “ANF” appears when the noise reduction is set to ON. •Speech compressor(p. 54) ➥While “M4” is selected, push [ (F-2)COM] to turn the speech compressor ON and OFF. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. • “COM” appears when the speech compressor is set to ON. • Push [ (F-2)COM] for 1 sec. to enter the compression level set mode. •VOX (voice operated transmit)(p. 53) ➥While “M4” is selected, push [ (F-1)VOX] to turn the VOX function ON and OFF. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. • “VOX” appears when the VOX function is set to ON. • Push [ (F-1)VOX] for 1 sec. to enter the VOX set mode.
42 4RECEIVE AND TRANSMIT DConvenient functions for receive DConvenient functions for transmit Operating FM qPush [(Y)BAND]/[(Z)BAND] to select the desired band. wPush [MODE] momentarily or for 1 sec. to select FM mode. • After FM or AM mode is selected, push [MODE] for 1 sec. to toggle between FM and AM modes. eRotate [AF] control to set audio to a comfortable lis- tening level. rRotate the main dial to tune a desired signal. • S-meter indicates received signal strength. • The default tuning step for FM mode is 1 kHz; this can be changed using the tuning step program mode. (p.19) tPush [PTT] (microphone) to transmit. • The TX indicator lights red. ySpeak into the microphone at your normal voice level. • Adjust ‘MIC GAIN’ at this step, if necessary. (p. 26) uRelease [PTT] (microphone) to return to receive. RLSB CH VFO APO S1 5 5 379 20 40 10 60dB USB CW RTTYAM WFM M1 SPL A/B XFC [TX] indicator [MODE] Main dial [AF] [Y] [Z] “FM” appears •Preamp and attenuator(p. 46) ➥Push [P.AMP/ATT] momentarily to set the preamp ON or OFF. • Lights green when the preamp is set to ON. ➥Push [P.AMP/ATT] for 1 sec. to set the attenuator ON. • Push [P.AMP/ATT] momentarily to turn the attenua- tor OFF. • Lights red when the attenuator is set to ON. •IF shift(p. 47) ➥Rotate [SHIFT] control.•Noise reduction(p. 50) ➥While “S4” is selected, push [(F-2)NR] to turn the noise reduction ON and OFF. • Push [DISPLAY] once or twice to select S. • Push [MENU] one or more times to select S4. • Push [(F-3)NRL] then rotate [M-CH] to adjust the noise reduction level. • “NR” appears when the noise reduction is set to ON. •Auto notch filter(p. 50) ➥While “S4” is selected, push [(F-1)ANF] to turn the auto notch filter function ON and OFF. • “ANF” appears when the noise reduction is set to ON. •VOX (voice operated transmit)(p. 53) ➥While “M4” is selected, push [ (F-1)VOX] to turn the VOX function ON and OFF. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. • “VOX” appears when the VOX function is set to ON. • Push [ (F-1)VOX] for 1 sec. to enter the VOX set mode. 4
43 4RECEIVE AND TRANSMIT Tone squelch operation is a method of communica- tions using selective calling. Only received signals having a matching tone will open the squelch. Before communicating using tone squelch, all members of your party must agree on the tone squelch frequency to use. qPush [MODE] one or more times to select FM mode. wSelect M4. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. ePush [(F-2)TON] for 1 sec. to enter the FM tone set mode. • Push [MENU] one or more times to select “T2 TONE SQL.” rRotate the main dial to set the desired subaudible tone frequency. • See left table for available tone frequencies. • Push [DISPLAY] to exit the FM tone set mode. tPush [(F-2)TON] once or twice to turn the tone squelch function. • “TSQL” appears. yCommunicate in the usual manner. • Push [PTT] to transmit; release to receive. •Available tone squelch frequencies(Unit: Hz) CH VFO APO S1 5 5 379 20 40 10 60dB FM TSQLSPL M4 VOX TON T2 TONE SQL FM [MODE]Main dial [DISPLAY] [MENU] [F-2] DTone squelch operation By monitoring a signal that is being transmitted on a repeater input frequency, you can determine the tone frequency necessary to open a repeater. qDuring tone squelch or repeater operation (“T” or “TSQL” is displayed, select M4. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M4. wPush [(F-2)TON] for 1 sec. to enter the FM tone set mode. • Push [MENU] one or more times to select “T3 T-SQL SCN” during tone squelch operation or “T3 RPTR-T SCN” during repeater operation. • If tone squelch function or tone encoder has not been selected, this item does not appear. ePush [(F-3)SCN] to toggle the tone scan operation ON and OFF. • While scanning, tone frequencies are displayed instead of the operating frequency. • When a matched tone is detected, tone scan automati- cally stops, the matched tone is displayed and the re- peater tone (or tone squelch tone) setting is automatically adjusted accordingly. rPush [DISPLAY] to exit the FM tone set mode. During repeater operation. PO S1 5 5 3792040 10 60dB FM T T3 RPTR-TSCN During tone squelch operation. PO S1 5 5 3792040 10 60dB FM TSQL T3 T-SQLSCN Main dial [DISPLAY] [MENU] [F-2] [F-3] 67.0 69.3 71.9 74.4 77.0 79.7 82.5085.4 088.5 091.5 094.8 097.4 100.0 103.5107.2 110.9 114.8 118.8 123.0 127.3 131.8136.5 141.3 146.2 151.4 156.7 159.8 162.2165.5 167.9 171.3 173.8 177.3 179.9 183.5186.2 189.9 192.8 196.6 199.5 203.5 206.5210.7 218.1 225.7 229.1 233.6 241.8 250.3254.1 DTone scan operation
44 4RECEIVE AND TRANSMIT T3 RPTR-T SCN(Repeater tone scan) During repeater operation, you can detect the tone frequency necessary to open a repeater. (see p. 45)The default is 88.5 Hz. FM-T T3 T-SQL SCN(Tone squelch tone scan) During tone squelch operation, you can detect the tone frequency necessary to communicate using tone squelch. (see p. 43)The default is 88.5 Hz. FM-TSQL T1 RPTR TONE This item selects a subaudible tone for FM-T mode operation to access a repeater. There are 50 tones available from 67.0 Hz to 254.1 Hz (see table at right). •Available subaudible tone frequencies (Unit: Hz) The default is 88.5 Hz. FM T2 TONE SQL This item sets a subaudible tone for tone squelch use. The same subaudible tone frequencies as for re- peater operation are available—see above The default is 88.5 Hz. FM While M4is selected in FM mode, push [(F-2)TON] for 1 sec. to enter the FM tone set mode. DFM tone set mode 67.0 69.3 71.9 74.4 77.0 79.7 82.5085.4 088.5 091.5 094.8 097.4 100.0 103.5107.2 110.9 114.8 118.8 123.0 127.3 131.8136.5 141.3 146.2 151.4 156.7 159.8 162.2165.5 167.9 171.3 173.8 177.3 179.9 183.5186.2 189.9 192.8 196.6 199.5 203.5 206.5210.7 218.1 225.7 229.1 233.6 241.8 250.3254.1 4
45 4RECEIVE AND TRANSMIT Repeater operation A repeater amplifies received signals and re-transmits them at a different frequency. When using a repeater, the transmit frequency is shifted from the receive fre- quency by an offset frequency. A repeater can be ac- cessed using split frequency operation with the shift frequency set to the repeater’s offset frequency. qSet the offset frequency and turn ON the quick split function in initial set mode in advance (pgs. 79, 80). • If the quick split function is turned OFF, both transmit and receive must be set separately. wPush [MODE] one or more times to select FM mode, then set the receive frequency. eSelect M1. • Push [DISPLAY] once or twice to select M. • Push [MENU] one or more times to select M1. rPush [(F-1)SPL] for 1 sec. to activate the split fre- quency function with the pre-selected offset. tSelect M4. • Push [MENU] one or more times to select M4. yPush [(F-2)TON] for 1 sec. to enter the FM tone set mode. • If FM mode has not been selected, this item does not appear. • Push [MENU] one or more times to select “T1 RPTR TONE.” • Rotate the main dial to set a subaudible tone frequency. • Push [DISPLAY] to exit the FM tone set mode. uPush [(F-2)TON] to turn the tone encoder. • “T” appears. iTo check the repeater input frequency (direct sig- nal from the other station), push and hold [ (F-3)XFC] in the M1display. oTo return to simplex operation, push [ (F-1)SPL] in the M1display. Each memory channel can store a tone frequency and an offset frequency, as well as the operating fre- quency. Store repeater information into memory chan- nels for quick and easy access to repeaters.•Available subaudible tone frequencies (Unit: Hz) CH VFO APO S1 5 5 379 20 40 10 60dB FM TSPL M4 VOX TON T1 RPTR TONE Set the tone fre- quency. See below table for available fre- quencies.FM CH VFO APO S1 5 5 379 20 40 10 60dB FMSPL M1 SPL A/B XFC 24 QUICK SPLIT Turn the quick split function ON. (Initial set mode default is ON.) [MODE]Main dial [DISPLAY] [MENU] [F-2] [F-3][F-1] CONVENIENT N NO OT TE E: : The split function may not be turned off when you change the operating band, push [(F-1)SPL] again to turn off the split function after you finish the repeater operation. 67.0 69.3 71.9 74.4 77.0 79.7 82.5085.4 088.5 091.5 094.8 097.4 100.0 103.5107.2 110.9 114.8 118.8 123.0 127.3 131.8136.5 141.3 146.2 151.4 156.7 159.8 162.2165.5 167.9 171.3 173.8 177.3 179.9 183.5186.2 189.9 192.8 196.6 199.5 203.5 206.5210.7 218.1 225.7 229.1 233.6 241.8 250.3254.1