Acronyms and abbreviations 103 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR Automatic Server Recovery BBWC battery-backed write cache BIOS Basic Input/Output System CSA Canadian Standards Association CSR Customer Self Repair DDR double data rate DIMM dual inline memory module ECC error checking and correcting FBDIMM fully buffered DIMM
Acronyms and abbreviations 104 HTTP hypertext transfer protocol IDE integrated device electronics IEC International Electrotechnical Commission iLO Integrated Lights-Out IML Integrated Management Log ISEE Instant Support Enterprise Edition LED light-emitting diode NFPA National Fire Protection Association NIC network interfac e controller NMI non-maskable interrupt NVRAM non-volatile memory ORCA Option ROM Configuration for Arrays OS operating system PCI peripheral component interface
Acronyms and abbreviations 105 PCI Express Peripheral Component Interconnect Express PCI-X peripheral component interconnect extended PCIe peripheral component interconnect express POST Power-On Self Test PPM processor power module PSP ProLiant Support Pack RBSU ROM-Based Setup Utility RDP Rapid Deployment Pack ROM read-only memory SAS serial attached SCSI SDRAM synchronous dynamic RAM SFF small form-factor SIM Systems Insight Manager SMTP Simple Mail Transfer Protocol
Acronyms and abbreviations 106 SNMP Simple Network Management Protocol TMRA recommended ambient operating temperature UID unit identification UPS uninterruptible power system USB universal serial bus VCA Version Control Agent
Index 107 A access panel 21, 22 ACU (Array Configuration Utility) 61 ADU (Array Diagnostic Utility) 66 Advanced ECC support 40 airflow requirements 27, 28 Altiris Deployment Solution 61 Array Configuration Utility (ACU) 61 Array Diagnostic Utility (ADU) 66 ASR (Automatic Server Recovery) 62 authorized reseller 95 auto-configuration process 59 Automatic Server Recovery (ASR) 62 Autorun menu 58 B backplane, hard drive 56 batteries, replacing 85, 90 battery 12, 85, 90 battery pack LEDs 17 battery-backed write cache battery pack 57 BIOS Serial Console 60 BIOS upgrade 62 boot options 60 BSMI notice 89 buttons 7, 8, 11 C cable management arm 24, 29 cables 72, 88 cabling 54, 55, 56, 57 Care Pack 26, 68 cautions 70 CD-ROM drive 45 Change Control 67 CMOS (complementary metal-oxide semiconductor) 12 component identification 7 components 7 components, system board 12 configuration of system 32, 58 Configuration Replication Utility 59 configuration tools 58 connection problems 72 connectors 7 contacting HP 95 controller options 54 controllers, array 54 creating a disk image 61 D DC power supply 47 Declaration of Conformity 87 deployment software 61 device numbers 15 diagnosing problems 69, 72 diagnostic tools 58, 61, 62, 65 diagnostics utility 65 diskette image creation 61 drive LEDs 15 drivers 66 DVD/CD-ROM drive, removing 45 E electrical grounding requirements 28 electrostatic discharge 92 environmental requirements 27 Erase Utility 63 European Union notice 88 expansion board 10, 49 expansion slot covers 50 expansion slots 10, 49, 50 external health LED 8 F fan board 19, 55 fan board connector 12, 19, 55 fan connectors 12, 19 fan module locations 19 fans 19 FBDIMM slot locations 12, 13 FBDIMMs 39 features 7 Index
Index 108 Federal Communicatio ns Commission (FCC) notice 86, 87, 88 flash ROM 62 flowcharts 73, 74, 76, 79, 80, 82 front panel components 7, 66 front panel LEDs 8 G general diagnosis flowchart 74 grounding methods 92 grounding requirements 28 H hard drive bays 7 hard drive blanks 44 hard drive LEDs 15 hard drives 15 hard drives, determining status of 15 hard drives, installing 43, 44 hard drives, removing 44 hardware options 33 hardware options installation 29, 33 health driver 62 health LEDs 8 heatsink 33 hot-plug fans 19, 24 HP Insight Diagnostics 65 HP ProLiant Essentials Foundation Pack 63 HP ProLiant Essentials R apid Deployment Pack 61 HP Systems Insight Manager, overview 63 I identification number 86 iLO (Integrated Lights-Out) 63 iLO 2 activity LED 11 iLO 2 diagnostic LED 12 iLO 2 link LED 10 iLO connector 10 IML (Integrated Management Log) 65 Important Safety Information document 69 Insight Diagnostics 65 installation services 26 installation, server options 29, 33 installing hardware 33 installing operating system 32 installing server 29 Instant Support Enterprise Edition 66 Integrated Lights-Out (iLO) 63 Integrated Management Log (IML) 65 internal health LED 8 internal USB connector 12 J Japanese notice 89 K keyboard connector 10 Korean notices 90 L laser devices 90 LED, internal health 8 LED, system power 8 LEDs 7 LEDs, battery pack 17 LEDs, hard drive 15 LEDs, NIC 8 LEDs, power supply 8 LEDs, SAS hard drive 15 LEDs, SATA hard drive 15 LEDs, troubleshooting 69 LEDs, unit identification (UID) 8 loose connections 72 M Management Agents 64 management tools 62 media drive 45 media drive bay 7, 56 media drive blank 45 memory 13, 39, 60 memory, configuration requirements 41, 42 memory, mirrored 42, 60, 61 memory, online spare 41, 60 mirrored memory 42 mouse connector 10 Multibay interface connector 12 N NIC connectors 10 NIC LEDs 8, 11 NMI jumper 13 NVRAM, clearing 12 O Online ROM Flash Component Utility 67
Index 109 online spare memory 41, 60 Open Services Event Manager 66 operating systems 32, 67 operations 20 optimum environment 27 Option ROM Configuration for Arrays (ORCA) 61 options installation 29, 33 ORCA (Option ROM Configuration for Arrays) 61 P PCI expansion slot definitions 10 PCI riser board 52 PCI riser cage connector 12 PCI slots 10, 11, 12 phone numbers 95 power cord 70, 91 power cord anchor 29 power cord connector 10 power distribution unit (PDU) 28 power LEDs, system 8 Power On/Standby button 8, 20, 32 power requirements 28 power supply 10 power supply backplane connector 12 power supply LEDs 11 powering down 20 powering up 20, 59 power-on problems flowchart 76 PPM (processor power module) 12, 33 PPM slots 11, 33 preparation procedures 72 problem diagnosis 69 processor 12, 33 processor installation tool 33 processor socket 12 ProLiant Support Pack (PSP) 67 PSPs, overview 67 Q quick release levers 7 R rack installation 26, 29 rack mounting hardware 29 rack resources 27 rack stability 70 rack warnings 29, 70 RBSU (ROM-Based Setup Utility) 59 RBSU configuration 59 rear components 10 rear panel components 10 rear panel connectors 10 rear panel LEDs 11 rear panel, accessing 24 redundant ROM 64 registering the server 32 regulatory compliance notices 86, 88 remote support and analysis tools 66 removing the access panel 21 required information 95 requirements, airflow 27 requirements, power 28 requirements, space 27 requirements, temperature 28 Resource Paqs 67 ROM redundancy 64 ROM, updating 67 ROM-Based Setup Utility (RBSU) 59 ROMPaq utility 62, 64 S safety considerations 29, 69 safety information 64 SAS device numbers 15 SAS drive numbers 15 SAS drives 15, 43, 44 SAS hard drive 43, 44 SAS hard drive LEDs 15 SATA hard drive LEDs 15 scripted installation 58 serial connector 10, 54 serial number 62 series number 86 server features and options 33 server, installation 29 service notifications 72 shipping carton contents 29 SmartStart autorun menu 58 SmartStart Scripting Toolkit 58 SmartStart, overview 58 software 58 space requirements 27 specifications 93 start diagnosis flowchart 73 static electricity 92 status lights, battery pack 17 StorageWorks Library and Tape Tools (L&TT) 63 support 66, 95 support packs 58
Index 110 supported operating systems 67 Survey Utility 65 symbols on equipment 70 system board battery 90 system board components 12 System Erase Utility 63 system maintenance switch 12 system power LED 8, 19 Systems Insight Display 7, 57 Systems Insight Display connector 19 Systems Insight Manager 63 T Taiwan battery recycling notice 91 technical support 95 telephone numbers 95 temperature requirements 28 Torx screwdriver 10 troubleshooting 69 U UID LEDs 7, 8, 11 updating the system ROM 64 USB connectors 7, 10, 12, 19 USB support 64 utilities 58 utilities, deployment 58, 59, 61 V ventilation 27 video connector 7, 10, 19 W warnings 29, 70 Web-Based Enterprise Service 66