HP Proliant Dl360 Generation 5 Server User Guide
Here you can view all the pages of manual HP Proliant Dl360 Generation 5 Server User Guide. The HP manuals for Server are available online for free. You can easily download all the documents as PDF.
Page 61
Hardware options installation 61 7. Disconnect the hard drive backplane power cable from the system board. 8. Turn the quarter-turn fasteners counter-clockwise and lift the integrated array controller away from the system board. 9. Connect the hard drive backplane power cable to the system board. 10. Install and route the cables from the PCI SAS or SATA array controller to the SAS hard drive backplane. CAUTION: When routing cables, use the cable trough be tween fan modules 1 and...
Page 62
Hardware options installation 62 14. Slide the server into the rack. 15. Power up the server (on page 18). Using a PCI array controller and the HP Smart Array P400i Controller to support six hard drives 1. Power down the server (on page 18). 2. Extend the server from the rack (on page 19). 3. Remove the access panel (on page 20). 4. Remove the air baffle. ( Remove the power supply air baffle on page 21, Remove the processor air baffle on page 22) 5. Remove fan modules 1 and 2 (...
Page 63
Cabling 63 Cabling In this section Cabling ov erview ........................................................................\ ....................................... .................... 63 Array controll er cabling ........................................................................\ ............................... ................... 63 Multibay backpla ne cabling ........................................................................\ ............................. ............... 66...
Page 64
Cabling 64 HP Smart Array E200i Controller cabling CAUTION: When routing cables, use the cable trough be tween fan modules 1 and 2. Be sure the cables do not interfere with fan module inst allation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfer e with access panel installation. HP Smart Array P400i Controller cabling CAUTION: When routing cables, use the cable trough be tween fan modules 1 and 2. Be sure the cables do not interfere...
Page 65
Cabling 65 PCI Smart Array controller cabling CAUTION: When routing cables, use the cable trough be tween fan modules 1 and 2. Be sure the cables do not interfere with fan module inst allation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfer e with access panel installation. IMPORTANT: When using a PCI array controller, be sure to remove the integrated array controller. Battery pack cabling • HP Smart Array E200i Controller battery...
Page 66
Cabling 66 • HP Smart Array P400i Controller battery pack cabling Multibay backplane cabling
Page 67
Configuration and utilities 67 Configuration and utilities In this section Configuratio n tools ........................................................................\ .................................... ..................... 67 Management tools........................................................................\ ....................................... ................... 71 Diagnostic tools ........................................................................\...
Page 68
Configuration and utilities 68 For more information, and to download the SmartS tart Scripting Toolkit, refer to the HP website ( http://www.hp.com/s ervers/sstoolkit ). Configuration Replication Utility ConRep is shipped in the SmartStart Scripting Toolkit and is a program that works with RBSU to replicate hardware configuration on ProLiant servers. This util ity is run during State 0, Run Hardware Configuration Utility, when doing a scripted server deployment. ConRep reads the state of the...
Page 69
Configuration and utilities 69 Drives installed Drives used RAID level 1 1 RAID 0 2 2 RAID 1 3, 4, 5, or 6 3, 4, 5, or 6 RAID 5 More than 6 0 None To change any ORCA default settings and overri de the auto-configuration process, press the F8 key when prompted. By default, the auto-configuration process configures the system for the English language. To change any default settings in the auto-configura tion process (such as the settings for language, operating system, and...
Page 70
Configuration and utilities 70 2. Access RBSU by pressing the F9 key during power-up when the pr ompt is displayed in the upper right corner of the screen. 3. Select System Options . 4. Select Advanced Memory Protection . 5. Select Mirrored Memory with Advanced ECC Support . 6. Press the Enter key. 7. Press the Esc key to exit the current menu or press the F10 key to exit RBSU. For more information on mirrored memory, refer to the white paper on the HP website (...