Home > HP > Server > HP Proliant Dl360 Generation 5 Server User Guide

HP Proliant Dl360 Generation 5 Server User Guide

Here you can view all the pages of manual HP Proliant Dl360 Generation 5 Server User Guide. The HP manuals for Server are available online for free. You can easily download all the documents as PDF.

Page 61

 
Hardware options  installation 61 
7.
 
Disconnect the hard drive backplane  power cable from the system board. 
 
8. Turn the quarter-turn fasteners counter-clockwise and  lift the integrated array controller away from the 
system board. 
9.  Connect the hard drive backplane power cable to the system board. 
10.  Install and route the cables from the PCI SAS or  SATA array controller to the SAS hard drive 
backplane. 
   CAUTION:   When routing cables, use the cable trough be tween fan modules 1 and...

Page 62

 
Hardware options  installation 62 
14.
 
Slide the server into the rack. 
15.  Power up the server (on page  18).  
Using a PCI array controller and the HP Smart Array P400i Controller to support 
six hard drives 
1. Power down the server (on page  18). 
2. Extend the server from the rack (on page  19). 
3. Remove the access panel (on page  20). 
4. Remove the air baffle. ( Remove the power supply air baffle  on page 21, Remove the processor 
air baffle  on page  22) 
5. Remove fan modules 1 and 2 (...

Page 63

 
Cabling 63 
Cabling 
In this section 
Cabling ov erview ........................................................................\
....................................... .................... 63 
Array controll er cabling ........................................................................\
............................... ................... 63 
Multibay backpla ne cabling ........................................................................\
............................. ............... 66...

Page 64

 
Cabling 64 
HP Smart Array E200i Controller cabling 
   CAUTION:   When routing cables, use the cable trough be tween fan modules 1 and 2. Be sure the cables 
do not interfere with fan module inst allation. Be sure to route the cables around the access panel mounting 
pin bracket so as not to interfer e with access panel installation. 
  
HP Smart Array P400i Controller cabling 
  CAUTION:   When routing cables, use the cable trough be tween fan modules 1 and 2. Be sure the cables 
do not interfere...

Page 65

 
Cabling 65 
PCI Smart Array controller cabling 
   CAUTION:   When routing cables, use the cable trough be tween fan modules 1 and 2. Be sure the cables 
do not interfere with fan module inst allation. Be sure to route the cables around the access panel mounting 
pin bracket so as not to interfer e with access panel installation. 
  IMPORTANT:   When using a PCI array controller, be sure  to remove the integrated array controller. 
  
Battery pack cabling 
• HP Smart Array E200i Controller battery...

Page 66

 
Cabling 66 
•
 
HP Smart Array P400i Controller battery pack cabling 
  
Multibay backplane cabling 
  

Page 67

 
Configuration and utilities  67 
Configuration and utilities 
In this section 
Configuratio n tools ........................................................................\
.................................... ..................... 67 
Management  tools........................................................................\
....................................... ................... 71 
Diagnostic  tools ........................................................................\...

Page 68

 
Configuration and utilities  68 
For more information, and to download the SmartS tart Scripting Toolkit, refer to the HP website 
( http://www.hp.com/s ervers/sstoolkit
).  
Configuration Replication Utility 
ConRep is shipped in the SmartStart Scripting Toolkit  and is a program that works with RBSU to replicate 
hardware configuration on ProLiant servers. This util ity is run during State 0, Run Hardware Configuration 
Utility, when doing a scripted server deployment. ConRep reads the state of the...

Page 69

 
Configuration and utilities  69 
     
Drives installed  Drives used  RAID level 
1 1 RAID 0 
2 2 RAID 1 
3, 4, 5, or 6  3, 4, 5, or 6  RAID 5 
More than 6  0  None  
To change any ORCA default settings and overri de the auto-configuration process, press the F8 key when 
prompted. 
By default, the auto-configuration  process configures the system for the English language. To change any 
default settings in the auto-configura tion process (such as the settings for language, operating system, and...

Page 70

 
Configuration and utilities  70 
2.
 
Access RBSU by pressing the  F9 key during power-up when the pr ompt is displayed in the upper 
right corner of the screen. 
3.  Select  System Options . 
4. Select  Advanced Memory Protection . 
5. Select  Mirrored Memory with Advanced ECC Support . 
6. Press the  Enter key. 
7. Press the  Esc key to exit the current menu or press the  F10 key to exit RBSU. 
For more information on mirrored memory, refer to the white paper on the HP website 
(...
Start reading HP Proliant Dl360 Generation 5 Server User Guide

Related Manuals for HP Proliant Dl360 Generation 5 Server User Guide

All HP manuals