Page 41
997-492-000-6, Issue 6 July 201134 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual 8 Specification General The Fire Control Panel meets the requirements of EN 54-2/ 4 and ISO 7240-2/4. See Section 1.4 CE Marking for further details. Mechanical: Construction: Fire-resistant, ABS plastic moulded front cover and back box. Cover contains all user interface controls and visual indicators. Dimensions (mm): 318(h) x 356(w) x 96(d) Approx. Weight: 2kg (no batteries)...
Page 42
997-492-000-6, Issue 6July 2011 35 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual Electrical: Classification: A combination of Installation Class 1 and Class 2 (panel must be earthed). Conductor size: Compatible with cable conductor sizes: 0.5mm 2 to 2.5mm2 . Supply Rating: Mains supply to the panel is to be provided via an external, double-pole, mains-isolation unit. The supply rating is: 230V~ (ac) ±15%, 50/ 60Hz, 1.6A. Power Supply Specification: Input Fuse...
Page 43
997-492-000-6, Issue 6 July 201136 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual Outputs: Sounder Circuits: Two outputs configurable as sounder, fire routing output or fault output and each rated at 0.5A. The sounder and fire routing outputs are monitored. 18.0 - 28.5Vdc, (24Vdc nominal) rated at 0.5A. Note: If the total alarm current (sounders + fire + Auxiliary output) exceeds a total load of 1A, you must check the total alarm load using the Battery Calculation...
Page 44
997-492-000-6, Issue 6July 2011 37 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual by EN 54-13. A fault of the 4-way sounder PCB is indicated by the Auxiliary fault indicator. The following output options are configurable:- Sounder output - ÜE transmission circuit - Fire protection output (SST) - Fire routing output - Fault routing output The following input options are configurable: - Fire transmission confirmed - Fault transmission confirmed - Class change - Day...
Page 45
997-492-000-6, Issue 6 July 201138 EN54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual 9 Battery Calculation The table in Section 6.4.1 Standby Batteries can be used to select the correct battery size. If full calculations are required use the procedure below. General Data PSU size Maximum Maximum Internal No. of sounder External Battery Size CircuitsAlarm LoadRange 1.8A 2 1A 2.8 - 7Ah Standby Load (Amps) Standby Load in Amps No. Current Total Basic panel1 0.034...