Have a look at the manual Honeywell Notifier Nfs28 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
997-492-000-6, Issue 6 July 201134 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual 8 Specification General The Fire Control Panel meets the requirements of EN 54-2/ 4 and ISO 7240-2/4. See Section 1.4 CE Marking for further details. Mechanical: Construction: Fire-resistant, ABS plastic moulded front cover and back box. Cover contains all user interface controls and visual indicators. Dimensions (mm): 318(h) x 356(w) x 96(d) Approx. Weight: 2kg (no batteries) Environmental: Climatic classification: 3K5, (IEC 721-2-3) Operating temperature: - 5 oC to +45oC, (recommended +5oC to 35oC) Humidity: 5% to 95% R.H. Height above sea level: Maximum, 2000m Panel sealing: IP 30, (EN 60529) Vibration: EN 60068-2-6, 10-150Hz at 0.981ms -2, 0.1g n (Meets the requirements of EN 54-2/4) EMC: Emissions: EN 61000-6-3 Immunity: EN 50130-4 Safety: EN 60950 Indicators and Controls: LED Status indicators: Alarm, Zonal Fire, Zonal Fault, Power, General Fault, General Disablement, Test, Delay On (active), System Fault, Earth Fault, Power Supply Fault, Sounder Fault/ Disabled, Fire Routing Active, Fire Routing OutputFault/Disabled, Fault Output Fault/Disabled, Auxiliary Fault. Controls: Two-position keyswitch: Level 1 (key removed or in ‘remove’ position) Level 2 access (key turned 90° clockwise). Dedicated push-buttons are provided for the following functions: ACCEPT, SOUNDERS STOP/START, RESET, BUZZER MUTE, DELAY ON/ OFF, ITEM SELECT, DISABLE/TEST/ NORMAL, LAMP TEST. External Connections: Cable entry: 18 x 20mm knock-outs on top face ofback box. One 25mm x 50mm knock- out on rear wall of back box.
997-492-000-6, Issue 6July 2011 35 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual Electrical: Classification: A combination of Installation Class 1 and Class 2 (panel must be earthed). Conductor size: Compatible with cable conductor sizes: 0.5mm 2 to 2.5mm2 . Supply Rating: Mains supply to the panel is to be provided via an external, double-pole, mains-isolation unit. The supply rating is: 230V~ (ac) ±15%, 50/ 60Hz, 1.6A. Power Supply Specification: Input Fuse rating: T 1.6A H 250V Output ratings: Output voltage: 18.5 - 28.5Vdc Output current: 1.8A (includes charger current - charger disabled during alarm) Ripple voltage: 200mV (peak-to-peak) Output Ratings - Charger: Charger voltage: 27.3Vdc at 20°C (temperature- compensated at -3mV/°C/cell) Charger current: 0.4A EN54 Battery Wiring Test Impedance: 0.8 Ohm EN54-4 PSU Loadings: I max(a)= 350mA @ 27Vdc I max(b)= 1.8A @ 27Vdc Range of battery size charged to 80% in 24hrs: 2.8Ah - 7Ah Recommended Standby Battery Sizes: 24 hour standby period - 2.8, 3.3 or 7Ah 72 hour standby period - 2.8, 3.3 or 7Ah. Note 1: Internal batteries - sealed lead-acid types are recommended. The following manufacturers/ type are recommended: Yuasa-NP, Fiamm FG and Jackyl. Note 2: To ensure compatibility with the battery wiring test batteries are to be 2.8Ah or greater. However, smaller Ah sizes will be compatible if the manufacturer’s stated initial charged internal resistance per battery is less than 80mOhms. Note 3: The batteries should be replaced at intervals not exceeding four years. Their lifetime is dependent upon the ambient temperature; refer to manufacturer’s technical specification for guidance.
997-492-000-6, Issue 6 July 201136 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual Outputs: Sounder Circuits: Two outputs configurable as sounder, fire routing output or fault output and each rated at 0.5A. The sounder and fire routing outputs are monitored. 18.0 - 28.5Vdc, (24Vdc nominal) rated at 0.5A. Note: If the total alarm current (sounders + fire + Auxiliary output) exceeds a total load of 1A, you must check the total alarm load using the Battery Calculation in Section 9. Zone Circuits: Factory-supplied two, four or eight detector zones. The quantity of detectors per zone equals 2.0mA divided by the individual detector’s quiescent current rating - see manufacturer’s data sheets - e.g. for a detector quiescent rating of 75 μA; the quantity of detectors: = 2.0mA ÷ 75 μA = 26 detectors. Auxiliary DC Output: 18.0V - 28.5Vdc (24Vdc nominal) rated at 0.5A Note: The length of any cables connected to the auxiliary output must not exceed 30m. Optional 2-Way Relay PCB providing: A Fire Relay Output A Fault Relay Output Each relay is rated at 30Vdc, 1A. Note: To comply with the requirements of EN 54-2: 8.8, if the 2-way Relay PCB is not fitted one of the sounder circuits must be configured as a fault output. Optional 8-Way Relay PCB providing up to 8 outputs per PCB (two PCBs may be fitted). Relay contact functions are configurable using jumper links to provide the following: Repeat Zonal Output or Coincident Zonal Output or Repeat Zonal Output (zones 1-4) and Shop Interface Outputs or Inputs and Shop Interface Outputs Max current (per PCB): Quiescent - 0.1mA Alarm/ all active - 80.1mA Each relay is rated at 30Vdc, 1A Fire resistor: Nominal 470R ±5% Optional 4-way sounder PCB supporting four configurable monitored outputs and two configurable input circuits. Various preset combinations of input and output functions are selected via a DIP switch. By using the supplied end-of- line termination the 4-way sounder PCB is able to provide sounder, fire routing and fault routing outputs as required by EN 54-2 and ISO 7240-2. These outputs are all monitored for partial-short and partial-open circuit faults as required EN 54-2: & ISO 7240-2 7.7.1 One output on the panel must be configured as a fire output. ! EN54 ISO 7240! EN54 ISO 7240 EN 54-13 : 5.3.4.1, 5.3.4.2 PSU PCB circuits do not comply with the requirement for partial- open and -short circuit fault monitoring on fire alarm device, fire routing and fault routing outputs.
997-492-000-6, Issue 6July 2011 37 EN 54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual by EN 54-13. A fault of the 4-way sounder PCB is indicated by the Auxiliary fault indicator. The following output options are configurable:- Sounder output - ÜE transmission circuit - Fire protection output (SST) - Fire routing output - Fault routing output The following input options are configurable: - Fire transmission confirmed - Fault transmission confirmed - Class change - Day Mode Maximum ouput current (per PCB): For two or more ouputs (if DIP switch 6 set to >250mA): 1.5A For each output (if DIP switch 6 set to
997-492-000-6, Issue 6 July 201138 EN54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual 9 Battery Calculation The table in Section 6.4.1 Standby Batteries can be used to select the correct battery size. If full calculations are required use the procedure below. General Data PSU size Maximum Maximum Internal No. of sounder External Battery Size CircuitsAlarm LoadRange 1.8A 2 1A 2.8 - 7Ah Standby Load (Amps) Standby Load in Amps No. Current Total Basic panel1 0.034 0.034 Device quiescent current (max 2mA per zone) EOL Current (per zone) - 0.0056 fitted with Resistor EOL Optional 4-way Sounder PCB(s) 0/ 1/ 20.047 Auxiliary equipment * Total Standby Load (L1) Peak/ Alarm Load (Amps) Alarm Load in Amps Qty Current Total Basic panel1 0.034 0.034 Zones alarm current 2/ 4/ 80.03 Optional 2-way Relay PCB 0/ 1 0.04 Optional 8-way Relay PCB(s) 0/ 1/ 2 0.08 Sounder output 1 Sounder output 2 4-way Sounder PCB outputs ** Auxiliary equipment * Total Alarm Current (L2) Total