Home > Honeywell > Scanner > Honeywell 20205 Manual

Honeywell 20205 Manual

Here you can view all the pages of manual Honeywell 20205 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.

Page 61

2 - 13
2020 Host Escape Commands
Command Action
 a Indicate as if successful menu change made
 b Indicate as if unsuccessful menu change made
 1 Illuminate green LED for 135 milliseconds (followed by at 
least 70 mSecs. dark time when multiple blinks)
 2 Illuminate green LED for two seconds (followed by at least 
500 mSecs. dark time when multiple blinks)
 3 Illuminate green LED for five seconds (followed by at least 
500 mSecs. dark time when multiple blinks)
 4 One beep at low pitch tone
 5 One beep at...

Page 62

2 - 14
Wand Emulation
Wand Emulation Connection
The Wand Emulation Connection bar codes should be used if you want to 
change the terminal ID only, without changing any other image scanner set-
tings.  We recommend using Wand Emulation Plug & Play bar codes to pro-
gram your image scanner to emulate a wand reader.  The Wand Emulation Plug 
& Play bar codes change other parameters, in addition to changing the terminal 
ID.   Please refer to Wand Emulation Plug & Playon page 1-22 for further infor-
mation....

Page 63

2 - 15
Wand Emulation Transmission Rate
The transmission rate is limited by the terminal’s ability to receive data without 
dropping characters.  Default = 25 inches/second.
Wand Emulation Polarity
The Polarity can be sent as standard with black bars high, or reversed with 
white bars high.  Default = Black High.
Wand Emulation Idle
The idle describes the state of the image scanner when no data is being trans-
mitted.  When in Wand Emulation mode, you must set the image scanner’s idle 
state to match the...

Page 64

2 - 16
Wand Emulation Data Block Size
This transmits the data in smaller blocks to prevent buffer overflow.  Default = 
40
.
Wand Emulation Delay Between Blocks
This sets the delay time between data blocks.  Default = 50ms.
Wand Emulation Overall Checksum
When this option is turned on, a computed check character is added at the end 
of the entire message.  The check character is the character which when Exclu-
sive-OR’d with every preceding character of the message yields a result of 0x00 
(00H)....

Page 65

3 - 1
3
Output
Image Scanner Functions
Good Read Indicators
Beeper – Good Read
The beeper may be programmed On or Off in response to a good read.  Turning 
this option off, only turns off the beeper response to a good read indication.  All 
error and menu beeps are still audible.  
Default = On.
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the image scanner 
emits on a good read.  Default = Medium.
* Beeper - Good Read On
 Beeper - Good Read Off
High* Medium
Off  Low 

Page 66

3 - 2
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the image 
scanner emits on a good read.  Default = Medium.
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the image scanner 
emits on a good read.  Default = Normal.
LED – Good Read
The LED indicator can be programmed On or Off in response to a good read.  Default = On.
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9.  The same...

Page 67

3 - 3
Good Read Delay
This sets the minimum amount of time before the image scanner can read 
another bar code.  Default = 0 ms (No Delay.)
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code 
below, then set the delay (from 0-30,000 milliseconds) by scanning digits from 
the inside back cover, then scanning 
Save. 
Image Scanner Trigger Modes
Manual/Serial Trigger, Low Power
You can activate the image scanner either by pressing the trigger, or...

Page 68

3 - 4
Read Time-Out (Serial Trigger Mode)
Use this selection to set a time-out (in milliseconds) of the image scanner’s 
trigger when using serial commands to trigger the image scanner.  Once the 
image scanner has timed out, you can activate the image scanner either by 
pressing the trigger or using a serial trigger command.  After scanning the Read 
Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by 
scanning digits on the Programming Chart inside the back cover, then...

Page 69

3 - 5
If there are no trigger pulls during the “image scanner power time-out timer” 
interval, the image scanner goes into power down mode.  Whenever the trigger 
is enabled, the “image scanner power time-out timer” is reset.  If the image 
scanner is placed in the 2020 cradle and the battery is in the process of being 
charged, the image scanner will not go into power down mode.
Note: When the image scanner is in power down mode, pull the trigger to power 
the unit back up.  There will be a set of power...

Page 70

3 - 6
Hands Free Time-Out
The Automatic Trigger and Presentation Modes are referred to as “hands free” 
modes.  If the image scanner’s trigger is pulled when using a hands free mode, 
the image scanner changes to manual trigger mode.  You can set the time the 
image scanner should remain in manual trigger mode by setting the Hands Free 
Time-Out.  Once the time-out value is reached, (if there have been no further 
trigger pulls) the image scanner reverts to the original hands free mode.  
Scan the 
Hands...
Start reading Honeywell 20205 Manual

Related Manuals for Honeywell 20205 Manual

All Honeywell manuals