Home > Honeywell > Scanner > Honeywell 1900gsr 2 User Manual

Honeywell 1900gsr 2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1900gsr 2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER
    3
    Xenon/Granit User Guide41
    CORDLESS SYSTEM OPERATION: 
    XENON 1902G/1912 AND 
    GRANIT 1911I/1981I
    Note:This chapter does not apply to corded or Xenon 1902g-BF scanners. See Cordless 
    System Operation: Xenon 1902g-BF beginning on page 81 for Xenon 1902g-BF 
    scanning systems.
    How the Cordless Charge Base/Access Point Works
    A cordless charge base or an Access Point provide the link between the cordless 
    scanner and the host system. The base/Access Point contains an interface assem-
    bly and an RF communication module. The RF communication module performs 
    the data exchange between the cordless scanner and the interface assembly. The 
    control assembly coordinates the central interface activities including: transmit-
    ting/receiving commands and data to/from the host system, performing software 
    activities (parameter menuing, visual indicator support, power-on diagnostics), 
    and data translation required for the host system.
    The cordless charge base is also a scanner’s battery charger. Refer to Charge 
    Information, page 47, for additional information.
    Link the Scanner to a Charge Base
    Turn off power before connecting a base, then power up the computer once the 
    base is fully connected. When the base is connected and powered up, put the scan-
    ner in the base to establish a link. The green LED on the base flashes to indicate 
    the scanner’s battery is charging. 
    						
    							42Xenon/Granit User Guide If the scanner and base have previously been linked, you do not receive any feed-
    back. If this is the first time that the scanner and base are linked, both devices emit 
    a short chirp when their radios link. At this point, that one scanner is linked to one 
    base.
    To determine if your cordless system is set up correctly, scan one of the sample bar 
    codes in the back of this manual. If the scanner provides a single good read beep 
    and the green LED lights, the scanner has successfully linked to the base. If using 
    a Granit scanner, the scanner also vibrates. If you receive an error tone and the red 
    LED lights, the scanner has not linked to the base. Refer to page 337 for trouble-
    shooting information.
    Link the Scanner to an Access Point
    Turn on the computer (laptop/desktop). Plug the interface 
    cable into the Access Point first and then into the appropri-
    ate port on the computer. The Page button lights up when 
    the connection to the host is made.
    Scan the linking bar code on the top of the Access Point to 
    establish a connection between the Access Point and the 
    scanner. The scanner emits a short beep and flashes the 
    green LED to confirm a connection with the Access Point. 
    The Access Point’s Page button remains blue.
     Xenon Scanner
    CCB01-010BT Charge Base 
    Page Button and Base LEDsGranit Scanner
    CCB02-100BT/CCB05-100BT  
    Charge Base Page Button and Base 
    LEDs
    Page 
    Button 
    						
    							Xenon/Granit User Guide43
    Replace a Linked Scanner
    If you need to replace a broken or lost scanner that is linked to a base or an Access 
    Point, scan the Override Locked Scanner bar code below with a new scanner and 
    place that scanner in the base, or scan the Access Point linking bar code. The 
    locked link will be overridden; the broken or lost scanner’s link with the base or 
    Access Point will be removed, and the new scanner will be linked.
    Communication Between the Cordless System 
    and the Host
    The cordless scanner provides immediate feedback in the form of a “good read” 
    indication with a green LED on the scanner and an audible beep. If using a Granit 
    scanner, the scanner also vibrates. This indicates that the bar code has been 
    scanned correctly and the base or Access Point has acknowledged receiving the 
    data. This is possible since the cordless system provides two-way communication 
    between the scanner and the base or Access Point.
    When data is scanned, the data is sent to the host system via the base or Access 
    Point. The cordless scanner recognizes data acknowledgment (ACK) from the base 
    or Access Point. If it cannot be determined that the data has been properly sent to 
    the base or Access Point, the scanner issues an error indication. You must then 
    check to see if the scanned data was received by the host system.
    1. Scanner reads code and gets ACK from base or Access Point
    2. Base or Access Point sends data to host
    Override Locked Scanner
    (Single Scanner)
    2
    1
    1
    2
    2 
    						
    							44Xenon/Granit User Guide
    Program the Scanner and Base or Access Point
    When using the scanner and charge base or Access Point together as a system, 
    menu parameters and configuration settings are stored in the charge base or 
    Access Point. Therefore, when programming any menu configuration settings, the 
    scanner must be linked to the intended charge base or Access Point.
    Note:This only applies when the scanner is linked to a charge base or Access Point. If the 
    scanner is in a non-base mode, configuration settings are stored in the scanner. 
    RF (Radio Frequency) Module Operation
    The cordless system uses a two-way Bluetooth® radio to transmit and receive data 
    between the scanner and the base or Access Point. Designed for point-to-point 
    and multi-point-to-single point applications, the radio operates using a license 
    free ISM band, which sends relatively small data packets at a fast data rate over a 
    radio signal with randomly changing frequencies, makes the cordless system 
    highly responsive to a wide variety of data collection applications and resistant to 
    noisy RF environments. The CCB01-010BT (Bluetooth Class 2) provides a commu-
    nication range of 33 feet (10m) between the scanner and base or Access Point, 
    depending on the environment. The CCB02-100BT/CCB05-100BT (Bluetooth 
    Class 1) provides a communication range of 330 feet (100m) between the scanner 
    and base or Access Point, depending on the environment. See Flexible Power 
    Management, page 59, for information about controlling this range.
    System Conditions
    The components of the cordless system interact in specific ways as you associate a 
    scanner to a base or Access Point, as you move a scanner out of range, bring a 
    scanner back in range, or swap scanners between two cordless systems. The fol-
    lowing information explains the cordless system operating conditions.
    Link Process
    Once a scanner is placed into a cordless charge base, the scanner’s battery charge 
    status is checked, and software automatically detects the scanner and links it to 
    the base depending on the selected link mode. 
    Refer to Link the Scanner to an Access Point, page 42, for information about link-
    ing to an Access Point.
    Scanner Is Out of Range
    The cordless scanner is in communication with its base or Access Point, even when 
    it is not transmitting bar code data. Whenever the scanner can’t communicate with 
    the base or Access Point for a few seconds, it is out of range. If the scanner is out of  
    						
    							Xenon/Granit User Guide45 range and you scan a bar code, the scanner issues an error tone indicating no com-
    munication with the base or Access Point. A cordless charge base can also sound 
    an alarm. Refer to Out-of-Range Alarm,page 56.
    Scanner Is Moved Back Into Range
    The scanner relinks if the scanner or the base or Access Point have been reset, or 
    the scanner comes back into range. If the scanner relinks, you will hear a single 
    chirp when the relinking process (uploading of the parameter table) is complete. 
    Refer to Out-of-Range Alarm on page 56 for further information.
    Out of Range and Back into Range with Batch Mode On
    The scanner may store a number of symbols (approximately 500 U.P.C. symbols; 
    others may vary) when it is out of range and then send them to the base or Access 
    Point when back in range (see Batch Mode on page 60). 
    You will not hear a communication error tone in this mode, but you will hear a short 
    buzz when you pull the trigger if the radio communication is not working. Once the 
    radio connection is made, the scanner produces a series of beeps while the data is 
    being transferred to the base or Access Point.
    Page Button
    When you press the Page button on the base or Access Point, the scanners associ-
    ated with that base or Access Point will begin beeping (3 short and 1 long beep). If 
    you pull the trigger on a scanner that is beeping in response, or press the Page but-
    ton on the base or Access Point a second time, all associated scanners will stop 
    beeping. See Page on page 52 for further information about Page Button settings. 
    Note:If you are using a Xenon 1902h model, refer to Quiet Operations - LED and Volume 
    Settings on page 149 for additional Page Button settings. 
    						
    							46Xenon/Granit User Guide
    Page Button and Presentation Modes
    When in Streaming Presentation Mode, the scanner’s aimer goes out after a short 
    time, but the scan illumination remains on all the time to continuously search for 
    bar codes (see Streaming Presentation™ Mode on page 127). When in Temporary 
    Streaming Presentation Mode, pressing the page button on the base puts the 
    scanner into Streaming Presentation Mode until the timeout occurs. If a bar code is 
    scanned before the timeout is reached, the timer starts over. 
    When the scanner is in the base, press the page button once to put the scanner 
    into Temporary Streaming Presentation Mode. When the scanner is in the base and 
    the base has external power (plugged into an outlet), press the page button twice 
    to put the scanner into Streaming Presentation Mode. Press it twice again to end 
    Streaming Presentation Mode. When the base does not have external power, press-
    ing the page button twice does not trigger Streaming Presentation Mode.
    When the scanner is out of the base, the page button works normally. Default = 
    Temporary Streaming Presentation Mode On.
    To remove Temporary Streaming Presentation Mode, scan the bar code for * Page 
    Mode On on page 52.
    * Temporary Streaming Presentation Mode 
    On 
    						
    							Xenon/Granit User Guide47
    Temporary Streaming Presentation Timeout
    Set a timeout for the length of time the illumination remains on and searching for 
    bar codes when using Temporary Streaming Presentation Mode. Set the length for 
    the timeout by scanning one of the bar codes below. Default = 10,000 ms (10 sec-
    onds).
    About the Battery
    Power is supplied to the cordless scanner by a rechargeable battery that is inte-
    grated in the scanner handle. Batteries are shipped only partially charged. The bat-
    tery should be charged for a minimum of 4 hours before initial use to ensure 
    optimal performance.
    Charge Information
    The battery is designed to charge while the scanner is positioned in the cordless 
    base unit. Refer to Base/Access Point LED Sequences and Meaning,page 49, for 
    an interpretation of the Charge Status indicators. Refer to Charge Only Mode (page 
    54) if you need to charge a scanner without linking it to the base.
    Place the scanner in the base that is connected to an appropriate power supply. 
    Use only a Listed Limited Power Source (LPS) or Class 2 type power supply with 
    output rated 5 to 5.2Vdc, 1A.
    Note:If you are powering the base through the interface cable (for example, a USB cable) 
    and not using an external power supply plugged into the aux port, the current 
    available for charging is reduced and charge times are increased. 
    *10 Second Timeout
    60 Second Timeout
    !!
    Warning:  There is a danger of explosion if the batteries are incorrectly 
    replaced. Replace the batteries with only the same or equivalent 
    type recommended by the manufacturer. Dispose of used 
    batteries according to the recycle program for batteries as 
    directed by the governing agency for the country where the 
    batteries are to be discarded. 
    						
    							48Xenon/Granit User Guide
    Battery Recommendations
    • The battery is a lithium ion cell and can be used without a full charge, and can 
    also be charged without fully discharging, without impacting the battery life. 
    There is no need to perform any charge/discharge conditioning on this type of 
    battery.
    • Keep the base connected to power when the host is not in use.
    • Replace a defective battery immediately since it could damage the scanner.
    • Although your battery can be recharged many times, it will eventually be 
    depleted. Replace it after the battery is unable to hold an adequate charge.
    • If you are not sure if the battery or charger is working properly, send it to 
    Honeywell International Inc. or an authorized service center for inspection. 
    Refer to Customer Support on page xvii for additional information.
    Safety Precautions for Lithium Batteries
    • Do not place batteries in fire or heat the batteries.
    • Do not store batteries near fire or other high temperature locations.
    • Do not store or carry batteries together with metal objects.
    • Do not expose batteries to water or allow the batteries to get wet.
    • Do not connect (short) the positive and negative terminals, of the batteries, to 
    each other with any metal object.
    • Do not pierce, strike or step on batteries or subject batteries to strong impacts or 
    shocks.
    • Do not disassemble or modify batteries. 
       
    Proper Disposal of the Battery
    When the battery has reached the end of its useful life, the battery 
    should be disposed of by a qualified recycler or hazardous materials 
    handler. Do not incinerate the battery or dispose of the battery with 
    general waste materials. You may send the scanner’s battery to us. 
    (postage paid). The shipper is responsible for complying with all fed-
    eral, state, and local laws and regulations related to the packing, 
    Caution:   Use only Honeywell Li-ion battery packs, model number BAT-
    SCN01, rated 3.7 Vdc, 7.4Whr in this device. Use of any non-
    Honeywell battery may result in damage not covered by the 
    warranty.
    Caution:   Danger of explosion if batteries are incorrectly replaced. 
    Dispose of used batteries according to the recycle program for 
    batteries as directed by the governing agency for the country 
    where the batteries are to be discarded. 
    						
    							Xenon/Granit User Guide49 labeling, manifesting, and shipping of spent batteries. Contact the Product Service 
    Department (page xvii) for recycling or disposal information. Since you may find 
    that your cost of returning the batteries significant, it may be more cost effective to 
    locate a local recycle/disposal company.
    Beeper and LED Sequences and Meaning
    The scanner contains LEDs on the rear of the unit that indicate linking status, 
    decoding state, and battery condition. The base has LEDs on the top of the unit 
    that indicate its power up, communication, and battery charge condition. The red 
    LED = error; green LED = success of any type. Scanners and the CCB01-010BT 
    base have audible indicators as well: 1 razz or error tone = error; 2 beeps = menu 
    change; 1 beep = all other successes.
    The table below lists the indication and cause of the LED indication, beeps, and 
    vibrations for the scanner.
    Scanner LED Sequences and Meaning
    Base/Access Point LED Sequences and Meaning
    The base contains a red LED and the Access Point has a blue LED that indicate the 
    status of the unit and verifies its communication with the host system. The base 
    also has a green LED that indicates scanner battery charge condition. 
    LED IndicationBeeper 
    IndicationVibrate 
    IndicationCause
    Normal 
    Operation
    Red Flash None None Battery low
    Green Flash 1 beep None Successful communication or 
    linking
    Red, blinking Razz or error tone None Failed communication
    Menu Operation
    Green Flash 2 beeps 2 vibrations Successful menu change
    Red, blinking Razz or error tone 1 long vibration Unsuccessful menu change
    Red or Blue LED - Host Communication
    Red or Blue LEDCommunication Condition
    Off USB suspend
    On continuously Power on, system idle
    Short blinks in multiple pulses. Occurs while transferring data to/
    from the RF module or the Host port.Receiving data 
    						
    							50Xenon/Granit User Guide
    Base Power Communication Indicator
    To display the power indicator on a base or an Access Point, scan the Base Power 
    Communication Indicator On bar code. To turn off the power indicator, scan the 
    Off bar code. Default = On. 
    Reset Scanner
    Scanning this bar code reboots the scanner and causes it to relink with the base or 
    Access Point.
    Scan While in Base Cradle
    Note:This feature only applies to the CCB01-010BT base.
    If you want to be able to scan bar codes while the scanner is in the base cradle, 
    scan the Scan in Cradle On bar code below. If you want to only allow scanning 
    when the scanner is out of the base cradle, scan Scan in Cradle Off. If you want the 
    scanner to shut down when in the base cradle, scan Shut Down Scanner in Cradle. 
    Default = Scan in Cradle On (for CCB01-010BT).
    Green LED - Scanner Battery
    (base only, does not apply to Access Point)
    Green LEDCharge Condition
    Off Battery not detected or charge 
    suspended
    Slow flash, 1 second on, 1 second off Pre-charge and charging
    On continuously Charge complete
    Fast flash, 300 mSec on, 300 mSec off Charge Error
    * Base Power Communication 
    Indicator On
    Base Power Communication 
    Indicator Off
    Reset Scanner 
    						