Home > Honeywell > Scanner > Honeywell 1900gsr 2 User Manual

Honeywell 1900gsr 2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1900gsr 2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Xenon/Granit User Guide 291
    Codabar Start/Stop Char.*Don’t Transmit CBRSSX0187
    Transmit CBRSSX1187
    Codabar Check Char.*No Check Char. CBRCK20187
    Validate, But Don’t Transmit CBRCK21187
    Validate, and Transmit CBRCK22187
    Codabar Concatenation *Off CBRCCT0188
    On CBRCCT1188
    Require CBRCCT2188
    Codabar Message Length Minimum (2 - 60)  *4 CBRMIN##189
    Maximum (2 - 60)  *60 CBRMAX##189
    Code 39 Default All Code 39 
    SettingsC39DFT189
    Off C39ENA0189
    *On C39ENA1189
    Code 39 Start/Stop Char.*Don’t Transmit C39SSX0189
    Transmit C39SSX1189
    Code 39 Check Char.*No Check Char. C39CK20190
    Validate, But Don’t 
    TransmitC39CK21190
    Validate, 
    and TransmitC39CK22190
    Code 39 Message Length Minimum (0 - 48)  *0 C39MIN##190
    Maximum (0 - 48)  *48 C39MAX##190
    Code 39 Append *Off C39APP0191
    On C39APP1191
    Code 32 Pharmaceutical (PARAF) *Off C39B320191
    On C39B321191
    Code 39 Full ASCII *Off C39ASC0191
    On C39ASC1191
    Code 39 Code Page C39DCP191
    Interleaved 2 of 5 Default All Interleaved
    2 of 5 SettingsI25DFT193
    Off I25ENA0193
    *On I25ENA1193
    Interleaved 2 of 5 Check Digit*No Check Char. I25CK20193
    Validate, But Don’t 
    TransmitI25CK21193
    Validate, and Transmit I25CK22193
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							292 Xenon/Granit User Guide
    Interleaved 2 of 5 Message Length Minimum (2 - 80)  *4 I25MIN##194
    Maximum (2 - 80)  *80 I25MAX##194
    NEC 2 of 5 Default All NEC
    2 of 5 SettingsN25DFT194
    Off N25ENA0194
    *On N25ENA1194
    NEC 2 of 5 Check Digit*No Check Char. N25CK20194
    Validate, But Don’t 
    TransmitN25CK21194
    Validate, and Transmit N25CK22194
    NEC 2 of 5 Message Length Minimum (2 - 80)  *4 N25MIN##195
    Maximum (2 - 80)  *80 N25MAX##195
    Code 93 Default All Code 93 
    SettingsC93DFT195
    Off C93ENA0195
    *On C93ENA1195
    Code 93 Message Length Minimum (0 - 80)  *0 C93MIN##196
    Maximum (0 - 80)  *80 C93MAX##196
    Code 93 Append On C93APP1196
    *Off C93APP0196
    Code 93 Code Page Code 93 Code Page C93DCP196
    Straight 2 of 5 Industrial Default All Straight 2 of 5 
    Industrial SettingsR25DFT197
    *Off R25ENA0197
    On R25ENA1197
    Straight 2 of 5 Industrial Message 
    LengthMinimum (1 - 48)  *4 R25MIN##197
    Maximum (1 - 48)  *48 R25MAX##197
    Straight 2 of 5 IATA Default All Straight 2 of 5 IATA
    SettingsA25DFT198
    Straight 2 of 5 IATA *Off A25ENA0198
    On A25ENA1198
    Straight 2 of 5 IATA Redundancy Range (0 - 10) *0 A25VOT##198
    Straight 2 of 5 IATA Message 
    LengthMinimum (1 - 48)  *4 A25MIN##198
    Maximum (1 - 48)  *48 A25MAX##198
    Matrix 2 of 5 Default All Matrix 2 of 5
    SettingsX25DFT199
    *Off X25ENA0199
    On X25ENA1199
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							Xenon/Granit User Guide 293
    Matrix 2 of 5 Message Length Minimum (1 - 80)  *4 X25MIN##199
    Maximum (1 - 80)  *80 X25MAX##199
    Code 11 Default All Code 11 
    SettingsC11DFT200
    *Off C11ENA0200
    On C11ENA1200
    Code 11 Check Digits Required 1 Check Digit C11CK20200
    *2 Check Digits C11CK21200
    Code 11 Message Length Minimum (1 - 80)  *4 C11MIN##200
    Maximum (1 - 80)  *80 C11MAX##200
    Code 128 Default All Code 128
    Settings128DFT201
    Off 128ENA0201
    *On 128ENA1201
    ISBT Concatenation *Off ISBENA0201
    On ISBENA1201
    Code 128 Redundancy Range (0 - 10) *0 128VOT##201
    Code 128 Message Length Minimum (0 - 80)  *0 128MIN##202
    Maximum (0 - 80)  *80 128MAX##202
    Code 128 Append *On 128APP1202
    Off 128APP0202
    Code 128 Code Page Code 128 Code Page (*2) 128DCP##202
    GS1-128 Default All GS1-128 Settings GS1DFT203
    *On GS1ENA1203
    Off GS1ENA0203
    GS1-128 Message Length Minimum (1 - 80)  *1 GS1MIN##203
    Maximum (0 - 80)  *80 GS1MAX##203
    Telepen Default All Telepen
    SettingsTELDFT204
    *Off TELENA0204
    On TELENA1204
    Telepen Output *AIM Telepen Output TELOLD0204
    Original Telepen Output TELOLD1204
    Telepen Message Length Minimum (1 - 60)  *1 TELMIN##204
    Maximum (1 - 60)  *60 TELMAX##204
    UPC-A Default All 
    UPC-A SettingsUPADFT205
    Off UPBENA0205
    *On UPBENA1205
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							294 Xenon/Granit User Guide
    UPC-A Check Digit Off UPACKX0205
    *On UPACKX1205
    UPC-A Number System Off UPANSX0206
    *On UPANSX1206
    UPC-A 2 Digit Addenda *Off UPAAD20206
    On UPAAD21206
    UPC-A 5 Digit Addenda *Off UPAAD50206
    On UPAAD51206
    UPC-A Addenda Required *Not Required UPAARQ0206
    Required UPAARQ1206
    Addenda Timeout Range (0 - 120) *500 DLYADD#####207
    UPC-A Addenda 
    SeparatorOff UPAADS0207
    *On UPAADS1207
    UPC-A/EAN-13 with Extended 
    Coupon Code*Off CPNENA0207
    Allow Concatenation CPNENA1207
    Require Concatenation CPNENA2207
    Addenda Timeout Range (0 - 120) *500 DLYADD#####208
    Coupon GS1 DataBar Output GS1 Output Off CPNGS10208
    GS1 Output On CPNGS11208
    UPC-E0 Default All UPC-E
    SettingsUPEDFT209
    Off UPEEN00209
    *On UPEEN01209
    UPC-E0 Expand *Off UPEEXP0209
    On UPEEXP1209
    UPC-E0 Addenda Required Required UPEARQ1209
    *Not Required UPEARQ0209
    Addenda Timeout Range (0 - 120) *500 DLYADD#####210
    UPC-E0 Addenda Separator *On UPEADS1210
    Off UPEADS0210
    UPC-E0 Check Digit Off UPECKX0210
    *On UPECKX1210
    UPC-E0 Leading Zero Off UPENSX0211
    *On UPENSX1211
    UPC-E0 Addenda 2 Digit Addenda On UPEAD21211
    *2 Digit Addenda Off UPEAD20211
    5 Digit Addenda On UPEAD51211
    *5 Digit Addenda Off UPEAD50211
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							Xenon/Granit User Guide 295
    UPC-E1 *Off UPEEN10211
    On UPEEN11211
    EAN/JAN-13 Default All EAN/
    JAN SettingsE13DFT212
    Off E13ENA0212
    *On E13ENA1212
    Convert UPC-A to EAN-13 UPC-A Converted to EAN-13 UPAENA0212
    Do not Convert UPC-A UPAENA1212
    EAN/JAN-13 Check Digit Off E13CKX0213
    *On E13CKX1213
    EAN/JAN-13 2 Digit Addenda 2 Digit Addenda On E13AD21213
    *2 Digit Addenda Off E13AD20213
    5 Digit Addenda On E13AD51213
    *5 Digit Addenda Off E13AD50213
    EAN/JAN-13 Addenda Required *Not Required E13ARQ0213
    Required E13ARQ1213
    Addenda Timeout Range (0 - 120) *500 DLYADD#####214
    EAN/JAN-13 Addenda 
    SeparatorOff E13ADS0214
    *On E13ADS1214
    ISBN Translate *Off E13ISB0214
    On E13ISB1214
    EAN/JAN-8 Default All EAN/
    JAN 8 SettingsEA8DFT215
    Off EA8ENA0215
    *On EA8ENA1215
    EAN/JAN-8 Check Digit Off EA8CKX0215
    *On EA8CKX1215
    EAN/JAN-8 Addenda *2 Digit Addenda Off EA8AD20215
    2 Digit Addenda On EA8AD21215
    *5 Digit Addenda Off EA8AD50215
    5 Digit Addenda On EA8AD51215
    EAN/JAN-8 Addenda Required *Not Required EA8ARQ0216
    Required EA8ARQ1216
    Addenda Timeout Range (0 - 120) *500 DLYADD#####216
    EAN/JAN-8 Addenda 
    SeparatorOff EA8ADS0216
    *On EA8ADS1216
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							296 Xenon/Granit User Guide
    MSI Default All MSI Settings MSIDFT217
    *Off MSIENA0217
    On MSIENA1217
    MSI Check Character *Validate Type 10, but Don’t 
    TransmitMSICHK0217
    Validate Type 10 and 
    TransmitMSICHK1217
    Validate 2 Type 10 Chars, but 
    Don’t TransmitMSICHK2218
    Validate 2 Type 10 Chars and 
    TransmitMSICHK3218
    Validate Type 11 then Type 10 
    Char, but Don’t TransmitMSICHK4218
    Validate Type 11 then Type 10 
    Char and TransmitMSICHK5218
    Disable MSI Check Characters MSICHK6218
    MSI Message Length Minimum (4 - 48) *4 MSIMIN##218
    Maximum (4 - 48) *48 MSIMAX##218
    GS1 DataBar Omnidirectional Default All 
    GS1 DataBar Omnidirectional 
    SettingsRSSDFT219
    Off RSSENA0219
    *On RSSENA1219
    GS1 DataBar Limited Default All GS1 DataBar Limited 
    SettingsRSLDFT219
    Off RSLENA0219
    *On RSLENA1219
    GS1 DataBar Expanded Default All GS1 DataBar 
    Expanded SettingsRSEDFT220
    Off RSEENA0220
    *On RSEENA1220
    GS1 DataBar Expanded Msg. 
    LengthMinimum (4 - 74) *4 RSEMIN##220
    Maximum (4 - 74) *74 RSEMAX##220
    Trioptic Code *Off TRIENA0220
    On TRIENA1220
    Codablock A Default All Codablock A Settings CBADFT221
    *Off CBAENA0221
    On CBAENA1221
    Codablock A Msg. Length Minimum (1 - 600) *1 CBAMIN###221
    Maximum (1 - 600) *600 CBAMAX###221
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							Xenon/Granit User Guide 297
    Codablock F Default All Codablock F Settings CBFDFT222
    *Off CBFENA0222
    On CBFENA1222
    Codablock F Msg. Length Minimum (1 - 2048) *1 CBFMIN####222
    Maximum (1 - 2048) *2048 CBFMAX####222
    Label Code On LBLENA1222
    * Off LBLENA0222
    PDF417 Default All PDF417 Settings PDFDFT223
    *On PDFENA1223
    Off PDFENA0223
    PDF417 Msg. Length Minimum (1-2750) *1 PDFMIN####223
    Maximum (1-2750)  *2750 PDFMAX####223
    MacroPDF417 *On PDFMAC1224
    Off PDFMAC0224
    MicroPDF417 Default All Micro PDF417 Settings MPDDFT224
    On MPDENA1224
    *Off MPDENA0224
    MicroPDF417 Msg. Length Minimum (1-366) *1 MPDMIN###224
    Maximum (1-366)  *366 MPDMAX###224
    GS1 Composite Codes On COMENA1225
    *Off COMENA0225
    UPC/EAN Version On COMUPC1225
    *Off COMUPC0225
    GS1 Composite Codes Msg. LengthMinimum (1-2435)  *1 COMMIN####225
    Maximum (1-2435) *2435 COMMAX####225
    GS1 Emulation GS1-128 Emulation EANEMU1226
    GS1 DataBar Emulation EANEMU2225
    GS1 Code Expansion Off EANEMU3226
    EAN8 to EAN13 Conversion EANEMU4226
    *GS1 Emulation Off EANEMU0226
    TCIF Linked Code 39 On T39ENA1227
    *Off T39ENA0227
    QR Code Default All QR Code Settings QRCDFT227
    *On QRCENA1227
    Off QRCENA0227
    QR Code Msg. Length Minimum (1-7089) *1 QRCMIN####227
    Maximum (1-7089) *7089 QRCMAX####227
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							298 Xenon/Granit User Guide
    QR Code Append *On QRCAPP1228
    Off QRCAPP0228
    QR Code Page QR Code Page (*3) QRCDCP##228
    Data Matrix Default All Data Matrix Settings IDMDFT229
    *On IDMENA1229
    Off IDMENA0229
    Data Matrix Msg. Length Minimum (1-3116) *1 IDMMIN####229
    Maximum (1-3116) *3116 IDMMAX####229
    Data Matrix Code Page Data Matrix Code Page (*51) IDMDCP##229
    MaxiCode Default All MaxiCode Settings MAXDFT230
    On MAXENA1230
    *Off MAXENA0230
    MaxiCode Msg. Length Minimum (1-150) *1 MAXMIN###230
    Maximum (1-150) *150 MAXMAX###230
    Aztec Code Default All Aztec Code Settings AZTDFT231
    *On AZTENA1231
    Off AZTENA0231
    Aztec Code Msg. Length Minimum (1-3832) *1 AZTMIN####231
    Maximum (1-3832) *3832 AZTMAX####231
    Aztec Append *On AZTAPP1231
    Off AZTAPP0231
    Aztec Code Page Aztec Code Page (*51) AZTDCP##232
    Chinese Sensible (Han Xin) Code Default All Han Xin Code Settings HX_DFT232
    On HX_ENA1232
    *Off HX_ENA0232
    Chinese Sensible (Han Xin) Code 
    Msg. LengthMinimum (1-7833) *1 HX_MIN####233
    Maximum (1-7833) *7833 HX_MAX####233
    Postal Codes - 2D
    2D Postal Codes *Off POSTAL0233
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							Xenon/Granit User Guide 299
    Single 2D Postal Codes Australian Post On POSTAL1233
    British Post On POSTAL7233
    Canadian Post On POSTAL30233
    Intelligent Mail Bar Code On POSTAL10233
    Japanese Post On POSTAL3234
    KIX Post On POSTAL4234
    Planet Code On POSTAL5234
    Postal-4i On POSTAL9234
    Postnet On POSTAL6234
    Postnet with B and B’ Fields On POSTAL11234
    InfoMail On POSTAL2234
    Combination 2D Postal Codes InfoMail and British Post  On POSTAL8234
    Intelligent Mail Bar Code and 
    Postnet with B and B’ Fields OnPOSTAL20234
    Postnet and Postal-4i On POSTAL14235
    Postnet and Intelligent Mail Bar 
    Code OnPOSTAL16235
    Postal-4i and Intelligent Mail Bar 
    Code OnPOSTAL17235
    Postal-4i and Postnet with B and 
    B’ Fields OnPOSTAL19235
    Planet and Postnet On POSTAL12235
    Planet and Postnet with B and B’ 
    Fields OnPOSTAL18235
    Planet and Postal-4i On POSTAL13235
    Planet and Intelligent Mail Bar 
    Code OnPOSTAL15235
    Planet, Postnet, and Postal-4i On POSTAL21235
    Planet, Postnet, and Intelligent 
    Mail Bar Code OnPOSTAL22235
    Planet, Postal-4i, and Intelligent 
    Mail Bar Code OnPOSTAL23236
    Postnet, Postal-4i, and Intelligent 
    Mail Bar Code OnPOSTAL24236
    Planet, Postal-4i, and Postnet with 
    B and B’ Fields OnPOSTAL25236
    Planet, Intelligent Mail Bar Code, 
    and Postnet with B and B’ Fields 
    OnPOSTAL26236
     Postal-4i, Intelligent Mail Bar 
    Code, and Postnet with B and B’ 
    Fields OnPOSTAL27236
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						
    							300 Xenon/Granit User Guide
    Planet, Postal-4i, Intelligent Mail 
    Bar Code, and Postnet  OnPOSTAL28236
    Planet, Postal-4i, Intelligent Mail 
    Bar Code, and Postnet with B and 
    B’ Fields OnPOSTAL29236
    Planet Code Check Digit Transmit PLNCKX1236
    *Don’t Transmit PLNCKX0237
    Postnet Check Digit Transmit NETCKX1237
    *Don’t Transmit NETCKX0237
    Australian Post Interpretation Bar Output AUSINT0237
    Numeric N Table AUSINT1237
    Alphanumeric C Table AUSINT2237
    Combination N and C Tables AUSINT3238
    Postal Codes - Linear
    China Post (Hong Kong 2 of 5)  Default All China Post (Hong Kong 
    2 of 5) SettingsCPCDFT238
    *Off CPCENA0238
    On CPCENA1238
    China Post (Hong Kong 2 of 5) 
    Msg. LengthMinimum (2 - 80) *4 CPCMIN##238
    Maximum (2 - 80) *80 CPCMAX##238
    Korea Post Default All Korea Post Settings KPCDFT239
    *Off KPCENA0239
    On KPCENA1239
    Korea Post Msg. Length Minimum (2 - 80) *4 KPCMIN##239
    Maximum (2 - 80) *48 KPCMAX##239
    Korea Post Check Digit Transmit Check Digit KPCCHK1239
    *Don’t Transmit Check Digit KPCCHK0239
    Imaging Default Commands
    Image Snap Default all Imaging Commands IMGDFT241
    Imaging Style - Decoding SNPSTY0242
    *Imaging Style - Photo SNPSTY1242
    Imaging Style - Manual SNPSTY2242
    Beeper On SNPBEP1242
    *Beeper Off SNPBEP0242
    *Wait for Trigger Off SNPTRG0243
    Wait for Trigger On SNPTRG1243
    *LED State - Off SNPLED0243
    LED State - On SNPLED1243
    Exposure (1-7874 microseconds) SNPEXP243
    SelectionSetting
    * Indicates defaultSerial Command
    # Indicates a numeric 
    entryPage 
    						