CHAPTER 1 Xenon/Granit User Guide1 GET STARTED About This Manual This User’s Guide provides installation and programming instructions for the Xenon™ 1900 corded area-imaging scanners, the Xenon 1902 cordless area-imag- ing scanners, the Granit 1910i and 1980i corded industrial scanners, and the Granit 1911i and 1981i cordless industrial scanners. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common ter- minal and communications settings. If you need to change these settings, pro- gramming is accomplished by scanning the bar codes in this guide. An asterisk (*) next to an option indicates the default setting. Unpack Your Device After you open the shipping carton containing the product, take the following steps: • Check for damage during shipment. Report damage immediately to the carrier who delivered the carton. • Make sure the items in the carton match your order. • Save the shipping container for later storage or shipping. Connect the Device Connect with USB A scanner or a cordless base can be connected to the USB port of a computer.
2Xenon/Granit User Guide 1. Connect the appropriate interface cable to the device first, then to the com- puter. Corded Xenon Scanner USB Connection: Corded Granit Scanner USB Connection:
Xenon/Granit User Guide3 2. If you are connecting a Granit scanner, make sure the cable is pushed tightly into the scanner. Loosen the locking plate and slide it over the base of the cable connector to lock the cable in place. Tighten the screw. Note:The power supply must be ordered separately, if needed. 3. If you are connecting a CCB01-010BT or CCB01-010BT-BF Base, make sure the cables are secured in the wireways in the bottom of the cordless base and the base sits flat on a horizontal surface. If you are connecting a CCB02-100BT or CCB05-100BT Base, see Mount a CCB02-100BT/CCB05-100BT Base on page 9. 4. The scanner beeps. 5. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols, beginning on page 351. The unit defaults to a USB PC Keyboard. Refer to page 18 for other USB terminal settings. CCB01-010BT/ CCB01-010BT-BF Base USB Connection: CCB02-100BT/ CCB05-100BT Base USB Connection:
4Xenon/Granit User Guide For additional USB programming and technical information, refer to “USB Applica- tion Note,” available at www.honeywellaidc.com. Connect with Keyboard Wedge A scanner or cordless base can be connected between the keyboard and PC as a “keyboard wedge,” where the scanner provides data output that is similar to key- board entries. Note:The Granit 1980i does not support the keyboard wedge interface. The following is an example of a keyboard wedge connection: 1. Turn off power and disconnect the keyboard cable from the back of the termi- nal/computer. 2. Connect the appropriate interface cable to the device and to the terminal/ computer. Corded Xenon Scanner Keyboard Wedge Connection: Corded Granit Scanner Keyboard Wedge Connection:
Xenon/Granit User Guide5 3. If you are connecting a Granit scanner, make sure the cable is pushed tightly into the scanner. Loosen the locking plate and slide it over the base of the cable connector to lock the cable in place. Tighten the screw. Note:The power supply must be ordered separately, if needed. 4. If you are connecting a CCB01-010BT or CCB01-010BT-BF Base, make sure the cables are secured in the wireways in the bottom of the cordless base and the base sits flat on a horizontal surface. If you are connecting a CCB02-100BT or CCB05-100BT Base, see Mount a CCB02-100BT/CCB05-100BT Base on page 9. 5. Turn the terminal/computer power back on. The scanner beeps. 6. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols, beginning on page 351. The scanner beeps once. If using a Granit scanner, it also vibrates. CCB01-010BT/CCB01-010BT-BF Base Keyboard Wedge Connection: CCB02-100BT/CCB05-100BT Base Keyboard Wedge Connection:
6Xenon/Granit User Guide The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard. A carriage return (CR) suffix is added to bar code data. Connect with RS232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. Note:For the scanner or cordless base to work properly, you must have the correct cable for your type of terminal/computer. Corded Xenon Scanner RS232 Serial Port Connection: Corded Granit Scanner RS232 Serial Port Connection:
Xenon/Granit User Guide7 3. If you are connecting a Granit scanner, make sure the cable is pushed tightly into the scanner. Loosen the locking plate and slide it over the base of the cable connector to lock the cable in place. Tighten the screw. Note:The power supply must be ordered separately, if needed. 4. If you are connecting a CCB01-010BTor CCB01-010BT-BF Base, make sure the cables are secured in the wireways in the bottom of the cordless base and the base sits flat on a horizontal surface. If you are connecting a CCB02-100BT or CCB05-100BT Base, see Mount a CCB02-100BT/CCB05-100BT Base on page 9. 5. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 6. Once the scanner or cordless base has been fully connected, power up the computer. This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit. CCB01-010BT/CCB01-010BT-BF Base RS232 Serial Port Connection: CCB02-100BT/CCB05/100BT Base RS232 Serial Port Connection:
8Xenon/Granit User Guide Connect with RS485 A Xenon scanner or cordless base can be connected for an IBM POS terminal inter- face. (This interface is not available in the Granit devices.) 1. Connect the appropriate interface cable to the device, then to the computer. Note:The power supply must be ordered separately, if needed. 2. Make sure the cables are secured in the wireways in the bottom of the cordless base and the base sits flat on a horizontal surface. 3. Turn the terminal/computer power back on. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols, beginning on page 351. The scanner beeps once. If using a Granit scanner, it also vibrates. For further RS485 settings, refer to RS485,page 16. Corded Xenon Scanner RS485 Connection: CCB01-010BT/CCB01-010BT-BF Base RS485 Connection:
Xenon/Granit User Guide9 Mount a CCB01-010BT Charge Base Mount a CCB02-100BT/CCB05-100BT Base The CCB02-100BT or CCB05-100BT Base can be mounted on either a horizontal or vertical surface. The cables can be routed through either the top or the bottom of the base. The cables can be routed down through the bottom of the base, securing the cables in the wireways. The cables can also be routed up through the top of the base, crossing them over and securing the cables in the wireways. When routing the cables up through the top of the base, be sure to cross the cables over before placing in the wireways. If not, too much strain is placed on the cable connectors. 8x32 thread x .39 in. (10mm) deep 2.36 in. 59.84mm 3.35 in. 85.09mm2.8 in. 72.1mm
10Xenon/Granit User Guide When mounted on a vertical surface, a locking system is used to secure the scan- ner when it is in the stand. When mounted on a horizontal surface, the locking mechanism should be set to unlocked (pushed up). When mounted on a vertical surface, the locking mechanism should be set to locked (pushed down). Use 30mm screws, appropriate for the mounting surface material, to mount the base securely. Locked position for vertical mountUnlocked position for horizontal mount 2 in. 51.17mm5.31 in. 134.92mm2.51 in. 63.7mm 2.36 in. 60mm .84 in. 21.42mm