Home > Honeywell > Scanner > Honeywell 1900gsr 2 User Manual

Honeywell 1900gsr 2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1900gsr 2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER
    1
    Xenon/Granit User Guide1
    GET STARTED
    About This Manual
    This User’s Guide provides installation and programming instructions for the 
    Xenon™ 1900 corded area-imaging scanners, the Xenon 1902 cordless area-imag-
    ing scanners, the Granit 1910i and 1980i corded industrial scanners, and the 
    Granit 1911i and 1981i cordless industrial scanners. Product specifications, 
    dimensions, warranty, and customer support information are also included.
    Honeywell bar code scanners are factory programmed for the most common ter-
    minal and communications settings. If you need to change these settings, pro-
    gramming is accomplished by scanning the bar codes in this guide.
    An asterisk (*) next to an option indicates the default setting.
    Unpack Your Device
    After you open the shipping carton containing the product, take the following 
    steps:
    • Check for damage during shipment. Report damage immediately to the carrier 
    who delivered the carton.
    • Make sure the items in the carton match your order.
    • Save the shipping container for later storage or shipping.
    Connect the Device
    Connect with USB
    A scanner or a cordless base can be connected to the USB port of a computer.  
    						
    							2Xenon/Granit User Guide 1. Connect the appropriate interface cable to the device first, then to the com-
    puter.
    Corded Xenon Scanner 
    USB Connection:
    Corded Granit Scanner 
    USB Connection: 
    						
    							Xenon/Granit User Guide3 2. If you are connecting a Granit scanner, make sure the cable is pushed tightly 
    into the scanner. Loosen the locking plate and slide it over the base of the cable 
    connector to lock the cable in place. Tighten the screw.
    Note:The power supply must be ordered separately, if needed.
    3. If you are connecting a CCB01-010BT or CCB01-010BT-BF Base, make sure 
    the cables are secured in the wireways in the bottom of the cordless base and 
    the base sits flat on a horizontal surface. If you are connecting a CCB02-100BT 
    or CCB05-100BT Base, see Mount a CCB02-100BT/CCB05-100BT Base on 
    page 9.
    4. The scanner beeps.
    5. Verify the scanner or cordless base operation by scanning a bar code from the 
    Sample Symbols, beginning on page 351.
    The unit defaults to a USB PC Keyboard. Refer to page 18 for other USB terminal 
    settings.
    CCB01-010BT/
    CCB01-010BT-BF Base
    USB Connection:
    CCB02-100BT/
    CCB05-100BT Base 
    USB Connection: 
    						
    							4Xenon/Granit User Guide For additional USB programming and technical information, refer to “USB Applica-
    tion Note,” available at www.honeywellaidc.com.
    Connect with Keyboard Wedge
    A scanner or cordless base can be connected between the keyboard and PC as a 
    “keyboard wedge,” where the scanner provides data output that is similar to key-
    board entries. 
    Note:The Granit 1980i does not support the keyboard wedge interface.
    The following is an example of a keyboard wedge connection:
    1. Turn off power and disconnect the keyboard cable from the back of the termi-
    nal/computer.
    2. Connect the appropriate interface cable to the device and to the terminal/
    computer.
    Corded Xenon Scanner 
    Keyboard Wedge 
    Connection:
    Corded Granit Scanner 
    Keyboard Wedge 
    Connection: 
    						
    							Xenon/Granit User Guide5 3. If you are connecting a Granit scanner, make sure the cable is pushed tightly 
    into the scanner. Loosen the locking plate and slide it over the base of the cable 
    connector to lock the cable in place. Tighten the screw.
    Note:The power supply must be ordered separately, if needed.
    4. If you are connecting a CCB01-010BT or CCB01-010BT-BF Base, make sure 
    the cables are secured in the wireways in the bottom of the cordless base and 
    the base sits flat on a horizontal surface. If you are connecting a CCB02-100BT 
    or CCB05-100BT Base, see Mount a CCB02-100BT/CCB05-100BT Base on 
    page 9.
    5. Turn the terminal/computer power back on. The scanner beeps.
    6. Verify the scanner or cordless base operation by scanning a bar code from the 
    Sample Symbols, beginning on page 351. The scanner beeps once. If using a 
    Granit scanner, it also vibrates. 
    CCB01-010BT/CCB01-010BT-BF Base 
    Keyboard Wedge Connection:
    CCB02-100BT/CCB05-100BT  Base 
    Keyboard Wedge Connection: 
    						
    							6Xenon/Granit User Guide The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with 
    a USA keyboard. A carriage return (CR) suffix is added to bar code data. 
    Connect with RS232 Serial Port
    1. Turn off power to the terminal/computer.
    2. Connect the appropriate interface cable to the scanner.
    Note:For the scanner or cordless base to work properly, you must have the correct cable for 
    your type of terminal/computer.
    Corded Xenon Scanner 
    RS232 Serial Port 
    Connection:
    Corded Granit Scanner RS232 Serial 
    Port Connection: 
    						
    							Xenon/Granit User Guide7 3. If you are connecting a Granit scanner, make sure the cable is pushed tightly 
    into the scanner. Loosen the locking plate and slide it over the base of the cable 
    connector to lock the cable in place. Tighten the screw.
    Note:The power supply must be ordered separately, if needed.
    4. If you are connecting a CCB01-010BTor CCB01-010BT-BF Base, make sure the 
    cables are secured in the wireways in the bottom of the cordless base and the 
    base sits flat on a horizontal surface. If you are connecting a CCB02-100BT or 
    CCB05-100BT Base, see Mount a CCB02-100BT/CCB05-100BT Base on page 
    9.
    5. Plug the serial connector into the serial port on your computer. Tighten the two 
    screws to secure the connector to the port.
    6. Once the scanner or cordless base has been fully connected, power up the 
    computer.
    This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit. 
    CCB01-010BT/CCB01-010BT-BF Base 
    RS232 Serial Port  Connection:
    CCB02-100BT/CCB05/100BT Base 
    RS232 Serial Port Connection: 
    						
    							8Xenon/Granit User Guide
    Connect with RS485
    A Xenon scanner or cordless base can be connected for an IBM POS terminal inter-
    face. (This interface is not available in the Granit devices.)
    1. Connect the appropriate interface cable to the device, then to the computer.
    Note:The power supply must be ordered separately, if needed.
    2. Make sure the cables are secured in the wireways in the bottom of the cordless 
    base and the base sits flat on a horizontal surface.
    3. Turn the terminal/computer power back on. The scanner beeps.
    4. Verify the scanner or cordless base operation by scanning a bar code from the 
    Sample Symbols, beginning on page 351. The scanner beeps once. If using a 
    Granit scanner, it also vibrates.
    For further RS485 settings, refer to RS485,page 16.
    Corded Xenon Scanner 
    RS485 Connection:
    CCB01-010BT/CCB01-010BT-BF Base 
    RS485 Connection: 
    						
    							Xenon/Granit User Guide9
    Mount a CCB01-010BT Charge Base
    Mount a CCB02-100BT/CCB05-100BT Base
    The CCB02-100BT or CCB05-100BT Base can be mounted on either a horizontal 
    or vertical surface. The cables can be routed through either the top or the bottom 
    of the base. 
    The cables can be routed down through the bottom of the base, securing the 
    cables in the wireways.
    The cables can also be routed up through the top of the base, crossing them over 
    and securing the cables in the wireways. 
    When routing the cables up through the top of the base, be sure to cross the cables 
    over before placing in the wireways. If not, too much strain is placed on the cable 
    connectors.
    8x32 thread 
    x .39 in. (10mm) deep 2.36 in.
    59.84mm
    3.35 in.
    85.09mm2.8 in.
    72.1mm 
    						
    							10Xenon/Granit User Guide When mounted on a vertical surface, a locking system is used to secure the scan-
    ner when it is in the stand. When mounted on a horizontal surface, the locking 
    mechanism should be set to unlocked (pushed up). When mounted on a vertical 
    surface, the locking mechanism should be set to locked (pushed down).
    Use 30mm screws, appropriate for the mounting surface material, to mount the 
    base securely.
     
    Locked position 
    for vertical mountUnlocked position 
    for horizontal mount
    2 in.
    51.17mm5.31 in.
    134.92mm2.51 in.
    63.7mm
    2.36 in.
    60mm
    .84 in.
    21.42mm 
    						
    All Honeywell manuals Comments (0)