Page 61

CHAPTER
3
Xenon/Granit User Guide41
CORDLESS SYSTEM OPERATION: 
XENON 1902G/1912 AND 
GRANIT 1911I/1981I
Note:This chapter does not apply to corded or Xenon 1902g-BF scanners. See Cordless 
System Operation: Xenon 1902g-BF beginning on page 81 for Xenon 1902g-BF 
scanning systems.
How the Cordless Charge Base/Access Point Works
A cordless charge base or an Access Point provide the link between the cordless 
scanner and the host system. The base/Access Point contains an interface assem-
bly and an RF...

Page 62

42Xenon/Granit User Guide If the scanner and base have previously been linked, you do not receive any feed-
back. If this is the first time that the scanner and base are linked, both devices emit 
a short chirp when their radios link. At this point, that one scanner is linked to one 
base.
To determine if your cordless system is set up correctly, scan one of the sample bar 
codes in the back of this manual. If the scanner provides a single good read beep 
and the green LED lights, the scanner has...

Page 63

Xenon/Granit User Guide43
Replace a Linked Scanner
If you need to replace a broken or lost scanner that is linked to a base or an Access 
Point, scan the Override Locked Scanner bar code below with a new scanner and 
place that scanner in the base, or scan the Access Point linking bar code. The 
locked link will be overridden; the broken or lost scanner’s link with the base or 
Access Point will be removed, and the new scanner will be linked.
Communication Between the Cordless System 
and the Host
The...

Page 64

44Xenon/Granit User Guide
Program the Scanner and Base or Access Point
When using the scanner and charge base or Access Point together as a system, 
menu parameters and configuration settings are stored in the charge base or 
Access Point. Therefore, when programming any menu configuration settings, the 
scanner must be linked to the intended charge base or Access Point.
Note:This only applies when the scanner is linked to a charge base or Access Point. If the 
scanner is in a non-base mode,...

Page 65

Xenon/Granit User Guide45 range and you scan a bar code, the scanner issues an error tone indicating no com-
munication with the base or Access Point. A cordless charge base can also sound 
an alarm. Refer to Out-of-Range Alarm,page 56.
Scanner Is Moved Back Into Range
The scanner relinks if the scanner or the base or Access Point have been reset, or 
the scanner comes back into range. If the scanner relinks, you will hear a single 
chirp when the relinking process (uploading of the parameter table) is...

Page 66

46Xenon/Granit User Guide
Page Button and Presentation Modes
When in Streaming Presentation Mode, the scanner’s aimer goes out after a short 
time, but the scan illumination remains on all the time to continuously search for 
bar codes (see Streaming Presentation™ Mode on page 127). When in Temporary 
Streaming Presentation Mode, pressing the page button on the base puts the 
scanner into Streaming Presentation Mode until the timeout occurs. If a bar code is 
scanned before the timeout is reached, the...

Page 67

Xenon/Granit User Guide47
Temporary Streaming Presentation Timeout
Set a timeout for the length of time the illumination remains on and searching for 
bar codes when using Temporary Streaming Presentation Mode. Set the length for 
the timeout by scanning one of the bar codes below. Default = 10,000 ms (10 sec-
onds).
About the Battery
Power is supplied to the cordless scanner by a rechargeable battery that is inte-
grated in the scanner handle. Batteries are shipped only partially charged. The bat-
tery...

Page 68

48Xenon/Granit User Guide
Battery Recommendations
• The battery is a lithium ion cell and can be used without a full charge, and can 
also be charged without fully discharging, without impacting the battery life. 
There is no need to perform any charge/discharge conditioning on this type of 
battery.
• Keep the base connected to power when the host is not in use.
• Replace a defective battery immediately since it could damage the scanner.
• Although your battery can be recharged many times, it will...

Page 69

Xenon/Granit User Guide49 labeling, manifesting, and shipping of spent batteries. Contact the Product Service 
Department (page xvii) for recycling or disposal information. Since you may find 
that your cost of returning the batteries significant, it may be more cost effective to 
locate a local recycle/disposal company.
Beeper and LED Sequences and Meaning
The scanner contains LEDs on the rear of the unit that indicate linking status, 
decoding state, and battery condition. The base has LEDs on the top...

Page 70

50Xenon/Granit User Guide
Base Power Communication Indicator
To display the power indicator on a base or an Access Point, scan the Base Power 
Communication Indicator On bar code. To turn off the power indicator, scan the 
Off bar code. Default = On. 
Reset Scanner
Scanning this bar code reboots the scanner and causes it to relink with the base or 
Access Point.
Scan While in Base Cradle
Note:This feature only applies to the CCB01-010BT base.
If you want to be able to scan bar codes while the scanner is...