Xenon/Granit User Guide 111The commands to which the scanner responds are listed on page 112. The [ESC] is 
a 1B in hex. A typical command string is [ESC] x,. [ESC] x is the escape command, 
and the comma is the terminator, which is required.
Example:Commands may be strung together to create custom response sequences. An 
example of a command string is listed below.
[ESC]4,[ESC]5,[ESC]6,
The above example will make a scanner beep low, then medium, then high.
Example:A good read beep is required for any...

Page 132

112 Xenon/Granit User Guide
Host ACK Timeout
You can set a timeout for the length of time the scanner waits for a valid escape 
command when using Host Acknowledgment Mode. Set the length (in seconds) for 
a timeout by scanning the following bar code, then setting the timeout (from 1-90 
seconds) by scanning digits from the Programming Chart, beginning on page 353, 
then Save. Default = 10.
Host ACK Responses
Host ACK Timeout
CommandAction
[ESC] a, Double beeps to indicate a successful menu change was...

Page 133

CHAPTER
5
Xenon/Granit User Guide 113
INPUT/OUTPUT SETTINGS
Power Up Beeper
Note:This feature does not apply to the CCB02-100BT/CCB05-100BT base.
The scanner can be programmed to beep when it’s powered up. If you are using a 
cordless system, the base can also be programmed to beep when it is powered up. 
Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up 
Beeper On - Scanner.
Power Up Beeper Off - 
Scanner
* Power Up Beeper On - 
Scanner
Power Up Beeper Off - 
Cordless Base...

Page 134

114 Xenon/Granit User Guide
Beep on BEL Character
You may wish to force the scanner to beep upon a command sent from the host. If 
you scan the Beep on BEL On bar code below, the scanner will beep every time a 
BEL character is received from the host. Default = Beep on BEL Off.
Trigger Click
To hear an audible click every time the scanner trigger is pressed, scan the Trigger 
Click On bar code below. Scan the Trigger Click Off code if you don’t wish to hear 
the click. (This feature has no effect on...

Page 135

Xenon/Granit User Guide 115
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the scanner emits on a 
good read. Default = High for Granit/Xenon, Low for Xenon HC.
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits 
on a good read. The Medium pitch differs for the Xenon and Granit scanners. 
Default = Medium.
Vibrate – Good Read
Note:Vibration settings apply only to Granit Devices.
* Low
Medium
* High
Off
Low (1600 Hz)...

Page 136

116 Xenon/Granit User GuideThe scanner vibrates once when a bar code is successfully read, and twice when a 
programming bar code is successfully read. When a programming bar code is 
unsuccessful, the scanner emits one long vibration (2 times the Vibrate Duration 
length). Scan Vibrate - Good Read Off to keep the scanner from vibrating. Default 
= Vibrate - Good Read On.
Vibrate Duration
If you want to set the length for the good read vibration, scan the bar code below, 
then set the duration (from 100...

Page 137

Xenon/Granit User Guide 117
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the scanner emits on a 
good read. Default = Normal.
LED – Good Read
The LED indicator can be programmed On or Off in response to a good read. 
Default = On.
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9. The same 
number of beeps will be applied to the beeper and LED in response to a good read. 
For example, if you program this option to have five...

Page 138

118 Xenon/Granit User Guideto an error. To change the number of error beeps, scan the bar code below and then 
scan a digit (1-9) bar code from the Programming Chart, beginning on page 353, 
then Save. Default = 1.
Beeper Volume Max
Note:The Beeper Volume Max feature only applies to Granit products.
Scan the following bar code to set all error and good read beeps to the maximum 
volume. This feature also sets the Beeper Pitch – Good Read to the highest level.
Good Read Delay
This sets the minimum amount...

Page 139

Xenon/Granit User Guide 119
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code below, 
then set the delay (from 0 - 30,000 milliseconds) by scanning digits from the 
Programming Chart, beginning on page 353, then Save. 
Trigger Modes
Manual Trigger
When in manual trigger mode, the scanner scans until a bar code is read, or until 
the trigger is released. Two modes are available, Normal and Enhanced. Normal 
mode offers good scan speed and the...

Page 140

120 Xenon/Granit User Guide
Trigger Number
This sets the number of trigger preses required to activate the Trigger Toggle Mode.
Trigger Timing
This sets the timing of the trigger presses in order to qualify as a trigger toggle, 
rather than a regular trigger press. After scanning the Trigger Timing bar code, set 
the time-out duration (from 50-2,000 milliseconds) by scanning digits from the 
Programming Chart, beginning on page 353, then Save. Default = 400ms.