Honeywell 1900ghd-2 User Manual
Here you can view all the pages of manual Honeywell 1900ghd-2 User Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 201
12 - 1 12 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming com- mand, refer to the corresponding programming bar code in this manual. The device must be set to an RS232 interface (see page 2-1). The following commands can be sent via a PC COM port using terminal emulation software. Conventions...
Page 202
12 - 2 SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device. Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence....
Page 203
12 - 3 This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Trigger Commands You can activate and deactivate the scanner with serial...
Page 204
12 - 4 Menu Commands SelectionSetting* Indicates default Serial Command # Indicates a numeric entryPage Product Default Settings Setting Custom Defaults Set Custom Defaults MNUCDP1-13 Save Custom Defaults MNUCDS1-13 Resetting the Custom Defaults Activate Custom Defaults DEFALT1-13 Resetting the Factory Defaults - cordless scannersFactory Default Settings: All Application GroupsPAPDFT&3-20 Resetting the Custom Defaults - cordless scannersCustom Default Settings: All Application GroupsPAPDFT3-21...
Page 205
12 - 5 Plug and Play Codes Verifone Ruby Terminal PAPRBY2-5 Gilbarco Terminal PAPGLB2-5 Honeywell Bioptic Aux Port PAPBIO2-5 Datalogic Magellan Aux Port PAPMAG2-6 NCR Bioptic Aux Port PAPNCR2-6 Wincor Nixdorf Terminal PAPWNX2-6 Wincor Nixdorf Beetle PAPBTL2-7 Wincor Nixdorf RS232 Mode A (not supported by all Granit models)PAPWMA2-7 Program Keyboard Country*U.S.A. KBDCTY02-8 Albania KBDCTY352-8 Azeri (Cyrillic) KBDCTY812-8 Azeri (Latin) KBDCTY802-8 Belarus KBDCTY822-8 Belgium KBDCTY12-8 Bosnia...
Page 206
12 - 6 Greek (Latin) KBDCTY632-11 Greek (MS) KBDCTY662-11 Greek (Polytonic) KBDCTY602-11 Hebrew KBDCTY122-11 Hungarian (101 key) KBDCTY502-11 Hungary KBDCTY192-11 Iceland KBDCTY752-11 Irish KBDCTY732-11 Italian (142) KBDCTY562-11 Italy KBDCTY52-11 Japan ASCII KBDCTY282-11 Kazakh KBDCTY782-12 Kyrgyz (Cyrillic) KBDCTY792-12 Latin America KBDCTY142-12 Latvia KBDCTY422-12 Latvia (QWERTY) KBDCTY432-12 Lithuania KBDCTY442-12 Lithuania (IBM) KBDCTY452-12 Macedonia KBDCTY342-12 Malta KBDCTY742-12 Mongolian...
Page 207
12 - 7 Turkey F KBDCTY272-14 Turkey Q KBDCTY242-15 Ukrainian KBDCTY762-15 United Kingdom KBDCTY72-15 United Stated (Dvorak right) KBDCTY892-15 United States (Dvorak left) KBDCTY882-15 United States (Dvorak) KBDCTY872-15 United States (International) KBDCTY302-15 Uzbek (Cyrillic) KBDCTY772-15 Keyboard Conversion *Keyboard Conversion Off KBDCNV02-16 Convert all Characters to Upper CaseKBDCNV12-16 Convert all Characters to Lower CaseKBDCNV22-16 Keyboard Style *Regular KBDSTY02-15 Caps Lock KBDSTY12-15...
Page 208
12 - 8 7 Data, 1 Stop, Parity None 232WRD02-20 7 Data, 1 Stop, Parity Odd 232WRD62-20 7 Data, 2 Stop, Parity Even 232WRD42-20 7 Data, 2 Stop, Parity None 232WRD12-20 7 Data, 2 Stop, Parity Odd 232WRD72-20 8 Data, 1 Stop, Parity Even 232WRD52-20 *8 Data, 1 Stop, Parity None 232WRD22-20 8 Data, 1 Stop, Parity Odd 232WRD82-20 8 Data, 1 Stop, Parity Mark 232WRD142-20 RS232 Receiver Time-out Range 0 - 300 seconds 232LPT###2-20 RS232 Handshaking *RTS/CTS Off 232CTS02-21 Flow Control, No Timeout 232CTS12-21...
Page 209
12 - 9 Number of Beeps - Base Error *1 BASERR33-9 Range 1 - 9 BASERR#3-9 Scanner Report Scanner Report RPTSCN3-9 Scanner Address Scanner Address BT_LDA3-9 Base Address Base Address:*:BASLDA3-9 Scanner Modes Charge Only Mode:*:BASLNK03-9 *Charge and Link Mode:*:BASLNK13-10 Locked Link Mode BASCON0,DNG13-10 *Open Link Mode BASCON1,DNG13-10 Unlink Scanner BT_RMV3-10 Override Locked Scanner BT_RPL13-11 Out-of-Range Alarm Base Alarm Duration (Range 1 - 3000 sec (*0))BASORD3-11 Scanner Alarm Duration (Range...
Page 210
12 - 10 Quantity Codes 0 BATNUM03-16 *1 BATNUM13-16 2 BATNUM23-16 3 BATNUM33-16 4 BATNUM43-16 5 BATNUM53-16 6 BATNUM63-16 7 BATNUM73-16 8 BATNUM83-16 9 BATNUM93-16 Batch Mode Output Order *FIFO BATLIF03-17 LIFO BATLIF13-17 Total Records Total Records BATNRC3-17 Delete Last Code Delete Last Code BATUND3-17 Clear All Codes Clear All Codes BATCLR3-17 Transmit Records to Host Transmit Inventory Records BAT_TX3-17 Batch Mode Transmit Delay *Off BATDLY03-18 Short (ms) BATDLY2503-18 Medium (ms) BATDLY5003-18...