Honeywell 1300g2 Owners Manual
Here you can view all the pages of manual Honeywell 1300g2 Owners Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 101
6 - 15 Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. * On Off Minimum Message Length Maximum Message Length
Page 102
6 - 16 Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. On Off Minimum Message Length Maximum Message Length
Page 103
6 - 17 Matrix 2 of 5 Matrix 2 of 5 Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. On * Off Minimum Message Length Maximum Message Length
Page 104
6 - 18 Code 11 Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. On * Off One Check Digit * Two Check Digits
Page 105
6 - 19 Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 128 Code 128 ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application...
Page 106
6 - 20 space-efficient design, 3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. Code 128 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Code 128 Code Page Code pages...
Page 107
6 - 21 Code 128 Function Code Transmit By default, Code 128 function codes are not transmitted with Code 128 bar code data. However, if you wish to transmit Code 128 function codes with the bar code data, scan the Function Codes On bar code, below. Default = Off Te l e p e n Code 128 Code Page * Function Codes Off Function Codes On
Page 108
6 - 22 Te l e p e n Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output. On * Off Original Telepen Output *AIM Telepen Output
Page 109
6 - 23 Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length
Page 110
6 - 24 UPC A UPC A UPC A Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not. Default = On. * On Off * On Off