Page 151

9 - 9
Turkey Q KBDCTY242-17
Ukrainian KBDCTY762-17
United Kingdom KBDCTY72-17
United Stated (Dvorak 
right)KBDCTY892-17
United States (Dvorak 
left)KBDCTY882-17
United States (Dvorak) KBDCTY872-17
United States 
(International)KBDCTY302-17
Uzbek (Cyrillic) KBDCTY772-17
Vietnam KBDCTY952-17
ALT Mode *Off KBDSTY02-18
4 Characters KBDALT02-18
Keyboard Style *Regular KBDALT72-18
Caps Lock KBDSTY12-18
Shift Lock KBDSTY22-19
Automatic Caps Lock KBDSTY62-19
Autocaps via 
NumLockKBDSTY72-19
Emulate External...

Page 152

9 - 10
*Numeric Keypad Off KBDNPS02-21
Numeric Keypad On KBDNPS12-21
*Auto Direct Conn. Off KBDADC02-21
Auto Direct Conn. On KBDADC12-21
Serial Port Connection RS-232 PAP2322-2
Baud Rate 300 BPS 232BAD02-22
600 BPS 232BAD12-22
1200 BPS 232BAD22-22
2400 BPS 232BAD32-22
4800 BPS 232BAD42-22
9600 BPS 232BAD52-22
19200 BPS 232BAD62-22
*38400 BPS 232BAD72-23
57600 BPS 232BAD82-23
115200 BPS 232BAD92-23
Word Length:  Data 
Bits, Stop Bits, and 
Par ity7 Data, 1 Stop, Parity 
None232WRD02-23
7 Data, 1 Stop,...

Page 153

9 - 11
8 Data, 1 Stop, Parity 
Odd232WRD82-24
RS-232 Handshaking *RTS/CTS Off 232CTS02-25
RTS/CTS Off, RTS 
Inactive232CTS102-25
 Flow Control, No 
Timeout232CTS12-25
Character-Based Flow 
Control, No Timeout232CTS72-26
Two-Direction Flow 
Control232CTS22-26
Flow Control with 
Timeout232CTS32-26
Character-Based Flow 
Control with Timeout    232CTS42-26
CTS-Based Flow 
Control, No Timeout232CTS52-26
 RTS On 232CTS82-26
No RTS if CTS is On 232CTS92-26
*XON/XOFF Off 232XON02-27
RS232 Timeout 232DEL####2-27...

Page 154

9 - 12
Beeper Volume - Good 
ReadOff BEPLVL03-1
Low BEPLVL13-1
Medium BEPLVL23-1
*High BEPLVL33-1
Beeper Pitch - Good 
Read  (Frequency)Low (1600 Hz) BEPFQ116003-2
*Medium (2750 Hz) BEPFQ127503-2
High (4200 Hz) BEPFQ142003-2
Beeper Duration - 
Good Read*Normal Beep BEPBIP03-2
Short Beep BEPBIP13-2
Beeper Pitch - Error *Razz (100 Hz)  BEPFQ21003-3
*Medium (2000 Hz) BEPFQ220003-3
High (4200 Hz) BEPFQ242003-3
LED - Good Read  Off BEPLED03-3
*On BEPLED13-3
Number of Beeps - 
Good Read *1 BEPRPT13-4
Range 1 -...

Page 155

9 - 13
Trigger Mode *Manual/Serial Trigger TRGMOD03-5
Read Time-Out (0 - 
300,000 ms) *30,000TRGSTO####3-5
Automatic Trigger TRGMOD13-5
Presentation Mode TRGMOD33-6
Continuous 
Illumination OnILLAON13-6
*Continuous 
Illumination OffILLAON03-6
Hands Free Time-Out 
(0-300,000 seconds) 
*5000TRGPTO####
##3-7
Reread Delay Short (500 ms) DLYRRD5003-7
*Medium (750 ms) DLYRRD7503-7
Long (1000 ms) DLYRRD10003-7
Extra Long (2000 ms) DLYRRD30003-7
User-Specified Reread 
DelayRange 0 - 30,000 ms DLYRRD#####3-8...

Page 156

9 - 14
No Read On SHWNRD13-14
*Off SHWNRD03-14
Video Reverse On VIDREV13-14
*Off VIDREV03-14
Prefix/Suffix Selections
Add CR Suffix to All Symbologies VSUFCR4-3
Prefix Add Prefix PREBK2##4-3
Clear One Prefix PRECL24-3
Clear All Prefixes PRECA24-3
Suffix Add Suffix SUFBK2##4-4
Clear One Suffix SUFCL24-4
Clear All Suffixes SUFCA24-4
Transmit Alternative 
Extended ASCII 
CharactersTransmit Alternate 
Extended ASCIIKBDEXT04-4
*Transmit Normal 
Extended ASCIIKBDEXT14-4
Function Code 
Tr a n s m i t*Enable...

Page 157

9 - 15
Data Formatter Off DFM_EN05-15
*On, but Not Required DFM_EN15-15
On, Required DFM_EN25-15
Symbologies
All Symbologies All Symbologies Off ALLENA06-2
All Symbologies On ALLENA16-2
Codabar Default All Codabar 
SettingsCBRDFT6-3
Codabar Off CBRENA06-3
*On CBRENA16-3
Codabar Start/Stop 
Char.*Don’t Transmit CBRSSX06-4
Transmit CBRSSX16-4
Codabar Check Char.*No Check Char. CBRCK206-4
Validate, But Don’t 
Tr a n s m i tCBRCK216-4
Validate, and Transmit CBRCK226-4
Codabar 
Concatenation*Off CBRCCT06-5
On...

Page 158

9 - 16
Code 39 Message 
LengthMinimum (0 - 48)  *0 C39MIN##6-8
Maximum (0 - 48)  *48 C39MAX##6-8
Code 39 Append *Off C39APP06-9
On C39APP16-9
Code 32 
Pharmaceutical 
(PARAF)*Off C39B3206-9
On C39B3216-9
Code 39 Full ASCII *Off C39ASC06-10
On C39ASC16-10
Interleaved 2 of 5 Default All Interleaved
2 of 5 SettingsI25DFT6-11
Interleaved 2 of 5 Off I25ENA06-11
*On I25ENA16-11
Interleaved 2 of 5 
Check Digit*No Check Char. I25CK206-12
Validate, But Don’t 
Tr a n s m i tI25CK216-12
Validate, and Transmit...

Page 159

9 - 17
Straight 2 of 5 IATA Default All Straight 2 of 
5 IATA
SettingsA25DFT6-16
Straight 2 of 5 IATA *Off A25ENA06-16
On A25ENA16-16
Straight 2 of 5 IATA 
Message LengthMinimum (1 - 48)  *4 A25MIN##6-16
Maximum (1 - 48)  *48 A25MAX##6-16
Matrix 2 of 5 Default All Matrix 2 of 
5
SettingsX25DFT6-17
Matrix 2 of 5 *Off X25ENA06-17
On X25ENA16-17
Matrix 2 of 5 Message 
LengthMinimum (1 - 80)  *4 X25MIN##6-17
Maximum (1 - 80)  *80 X25MAX##6-17
Code 11 Default All Code 11 
SettingsC11DFT6-18
Code 11 *Off...

Page 160

9 - 18
Code 128 Function 
Code Transmit*Off 128FNX06-21
On 128FNX16-21
Telepen Default All Telepen
SettingsTELDFT6-22
Telepen *Off TELENA06-22
On TELENA16-22
Telepen Output *AIM Telepen Output TELOLD06-22
Original Telepen 
OutputTELOLD16-22
Telepen Message 
LengthMinimum (1 - 60)  *1 TELMIN##6-23
Maximum (1 - 60)  *60 TELMAX##6-23
UPC A Default All 
UPC A SettingsUPADFT6-24
UPC A Off UPAENA06-24
*On UPAENA16-24
UPC A Check Digit Off UPACKX06-24
*On UPACKX16-24
UPC A Number 
SystemOff UPANSX06-25
*On...
Start reading Honeywell 1300g2 Owners Manual

Related Manuals for Honeywell 1300g2 Owners Manual

All Honeywell manuals