Page 61

4 - 1
4
Data Editing
Prefix/Suffix Overview
When a bar code is scanned, additional information is sent to the host computer 
along with the bar code data.  This group of bar code data and additional, 
user-defined data is called a “message string.”  The selections in this section 
are used to build the user-defined data into the message string.
Prefix and Suffix characters are data characters that can be sent before and 
after scanned data.  You can specify if they should be sent with all symbologies,...

Page 62

4 - 2
To Add a Prefix or Suffix
Step 1.Scan the Add Prefix or Add Suffix symbol (page 4-3).
Step 2.Determine the 2 digit Hex value from the Symbology Chart (included in 
Appendix A) for the symbology to which you want to apply the prefix or 
suffix.  For example, for Code 128, Code ID is “j” and Hex ID is “6A”.
Step 3.Scan the 2 hex digits from the  inside the back cover of this manual or 
scan 9, 9 for all symbologies.
Step 4.Determine the hex value from the ASCII Conversion Chart (Code Page 
1252),...

Page 63

4 - 3
Step 1.Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2.Determine the 2 digit Hex value from the Symbology Chart (included in 
Appendix A) for the symbology from which you want to clear the prefix 
or suffix.
Step 3.Scan the 2 digit hex value from the  inside the back cover of this man-
ual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to All Symbologies
Scan the following bar code if you wish to add a carriage return suffix to all...

Page 64

4 - 4
Suffix Selections
Transmit Alternate Extended ASCII Characters
You may need to emulate special keyboard functions, such as up or down 
arrows, Alt/Make or Alt/Break commands, that are not supported in the 
Extended ASCII Character table.   Refer to Alternate Extended ASCII Charac-
ters (page 4-5) for a range of keyboard function keys and corresponding deci-
mal and hex characters.  If you scan the Transmit Alternate Extended ASCII 
code, any hex entries in a prefix or suffix will result in the...

Page 65

4 - 5
Alternate Extended ASCII Characters
DECHEXKeyboard FunctionDECHEXKeyboard Function
12880up arrow ↑15298 F9
12981down arrow ↓15399 F10
13082right arrow →1549A F11
13183left arrow ←1559B F12
13284 Insert1569C Numeric Keypad +
13385 Delete1579D Numeric Keypad -
13486 Home1589E Numeric Keypad *
13587 End1599F Caps Lock
13688 Page Up160A0 Num Lock
13789 Page Down161A1Left Alt
1388A Right ALT162A2Left Ctrl
1398B Right CTRL163A3Left Shift
1408C Reserved164A4Right Shift
141 8D Reserved165A5Print Screen...

Page 66

4 - 6
Function Code Transmit
When this selection is enabled and function codes are contained within the 
scanned data, the scanner transmits the function code to the terminal.  Charts 
of these function codes are provided in Supported Interface Keys starting on 
page 7-2.  When the scanner is in keyboard wedge mode, the scan code is con-
verted to a key code before it is transmitted. Default = Enable.
Intercharacter, Interfunction, and Intermessage 
Delays
Some terminals drop information (characters) if...

Page 67

4 - 7
Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed between the 
transmission of each character of scanned data.  Scan the Intercharacter 
Delay bar code below, then scan the number of steps in 5 millisecond incre-
ments and the Save bar code using the  inside the back cover of this manual.
To remove this delay, scan the Intercharacter Delay bar code, then set the 
number of steps to 0.  Scan the Save bar code using the inside the back cover 
of this manual.
Note:...

Page 68

4 - 8
To remove this delay, scan the Delay Length bar code, and set the number of 
steps to 0.  Scan the Save bar code using the  inside the back cover of this 
manual.
Interfunction Delay
An interfunction delay of up to 495 milliseconds may be placed between the 
transmission of each control character in the message string.  Scan the Inter-
function Delay bar code below, then scan the number of steps in 5 millisecond 
increments and the Save bar code using the  inside the back cover of this man-
ual.
To...

Page 69

4 - 9
To remove this delay, scan the Intermessage Delay bar code, then set the 
number of steps to 0.  Scan the Save bar code using the  inside the back cover 
of this manual. 

Page 70

4 - 10 
Start reading Honeywell 1300g2 Owners Manual

Related Manuals for Honeywell 1300g2 Owners Manual