Honeywell 1300g2 Manual
Here you can view all the pages of manual Honeywell 1300g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 41
2 - 25 RTS/CTS Off, RTS Inactive: RTS/CTS is turned off so no data flow control is used and RTS is inactive. Flow Control, No Timeout: The scanner asserts RTS when it has data to send, and will wait indefinitely for CTS to be asserted by the host. Character-Based Flow Control, No Timeout: The scanner asserts RTS when it has a character to send, and will wait indefinitely for CTS to be asserted by the host Two-Direction Flow Control: The scanner asserts RTS when it is OK for the host to transmit....
Page 42
2 - 26 Character-Based Flow Control, No Timeout Two-Direction Flow Control Flow Control with Timeout Character-Based Flow Control with Timeout CTS-Based Flow Control, No Timeout RTS On No RTS if CTS is On
Page 43
2 - 27 RS232 Timeout When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1- 65535 milliseconds) by scanning digits from the inside back cover, then scan- ning Save. Default = 1000. XON/XOFF Standard ASCII control characters can be used to tell the scanner to start send- ing data (XON/XOFF On) or to stop sending data (XON/XOFF...
Page 44
2 - 28 for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On bar code below. To turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off. Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner. See RS232 Modifiers on page 2-22, and RS232 Timeouton...
Page 45
3 - 1 3 Input/Output Settings Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High. * On Off *HighMedium Off Low
Page 46
3 - 2 Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. Low (1600 Hz) * Medium (2750 Hz) High (4200 Hz) * Normal Beep Short Beep
Page 47
3 - 3 Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = 100 Hz. LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have...
Page 48
3 - 4 LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the inside the back cover of this manual. Default = One. Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = No Delay. User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000...
Page 49
3 - 5 Trigger Modes Manual/Serial Trigger You can activate the scanner either by pressing the trigger, or using a serial trig- ger command (see Trigger Commandson page 9-4). When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent. In serial mode, the scanner can also be set to turn itself off after a specified time has elapsed (see Read...
Page 50
3 - 6 Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until a change occurs in the scanner’s field of view. Then the LEDS turn on automatically to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly. Continuous Illumination Mode (Manual Trigger only) If you have several bar codes that are close together, you may wish to have a continuous aiming beam on in order to properly aim...