Honeywell 1300g2 Manual
Here you can view all the pages of manual Honeywell 1300g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 11
1 - 1 1 Getting Started About This Manual This User’s Guide provides installation and programming instructions for the Hyperion 1300g. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. An asterisk (*) next to an option indicates the...
Page 12
1 - 2 3. Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual. For additional USB programming and technical information, refer to the Honey- well “USB Application Note,” available at www.honeywellaidc.com. Connecting with Keyboard Wedge A scanner can be connected between the keyboard and PC as a “keyboard wedge,” where the scanner provides data output that is similar to keyboard entries. The following is an example of a keyboard wedge connection: 1....
Page 13
1 - 3 Connecting with RS-232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. 3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 4. Once the scanner has been completely connected, power up the computer. 5. This interface programs 38,400 baud, 8 data bits, no parity, and 1 stop bit. Connecting with RS485 A scanner can be connected for an IBM POS terminal...
Page 14
1 - 4 1. Connect the appropriate interface cable to the device, then to the computer. 2. Turn the terminal/computer power back on. The scanner beeps. 3. Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual. The scanner beeps once. 4. For further RS485 settings, refer to RS485on page 2-2. Reading Techniques The scanner has a bright red aiming beam that corresponds to its horizontal field of view. The aiming beam should be centered horizontally over...
Page 15
1 - 5 The best focus point for reading most code densities is about 5 inches (12.7 cm) from the unit. To read a single bar code or multiple bar codes (on a page or on an object), hold the scanner at an appropriate distance from the target, pull the trigger, and center the aiming beam on the bar code. Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by send- ing serial commands to the scanner. If you want to restrict the ability to scan menu codes, you...
Page 16
1 - 6 The Serial Programming Commands starting on page 9-1 lists the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages).
Page 17
2 - 1 2 Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge If you want your system programmed for an IBM PC AT and compatibles key- board wedge interface with a USA keyboard, scan the bar code...
Page 18
2 - 2 RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar code also programs a car- riage return (CR) and a line feed (LF) suffix, baud rate, and data format as indi- cated below. RS485 Scan one of the following “Plug and Play” codes to program the scanner for an IBM POS terminal interface. Note: After scanning one of these codes, you must power cycle the cash register. OptionSetting Baud Rate 38,400 bps...
Page 19
2 - 3 Each bar code above also programs the following suffixes for each symbology: * Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface OPOS Mode The following bar code configures your scanner for OPOS (OLE for Retail Point of Sale) by modifying the following OPOS-related settings: SymbologySuffixSymbologySuffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5...
Page 20
2 - 4 USB IBM SurePos Scan the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) interface. Note: After scanning the code below, you must power cycle the cash register. The bar code above also programs the following suffixes for each symbology: SymbologySuffixSymbologySuffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC E 0A Code 39 00 0A 0B OPOS Mode USB IBM SurePos (USB Handheld Scanner)...