Page 101

6 - 15
Straight 2 of 5 Industrial (three-bar start/stop)

Straight 2 of 5 Industrial
Straight 2 of 5 Industrial Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 1-48.  Minimum Default = 4, Maximum Default = 48.
* On
Off
Minimum Message Length
Maximum Message Length 

Page 102

6 - 16
Straight 2 of 5 IATA (two-bar start/stop)

Straight 2 of 5 IATA
Straight 2 of 5 IATA Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 1-48.  Minimum Default = 4, Maximum Default = 48.
On
 Off
Minimum Message Length
Maximum Message Length 

Page 103

6 - 17
Matrix 2 of 5

Matrix 2 of 5
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 1-80.  Minimum Default = 4, Maximum Default = 80.
On
*  Off
Minimum Message Length
Maximum Message Length 

Page 104

6 - 18
Code 11

Code 11
Check Digits Required
This option sets whether 1 or 2 check digits are required with Code 11 bar 
codes.  Default = Two Check Digits.
On
*  Off
One Check Digit
*  Two Check Digits 

Page 105

6 - 19
Code 11 Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 1-80.   Minimum Default = 4, Maximum Default = 80.
Code 128

Code 128
ISBT 128 Concatenation
In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard  
for communicating critical blood information in a uniform manner.  The use of 
ISBT formats requires a paid license. The ISBT 128 Application...

Page 106

6 - 20
space-efficient design, 3) a variation of Code 128 that supports concatenation 
of neighboring symbols, and 4) the standard layout for bar codes on a blood 
product label.  Use the bar codes below to turn concatenation on or off.  Default 
=Off.
Code 128 Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 0-80.   Minimum Default = 0, Maximum Default = 80.
Code 128 Code Page
Code pages...

Page 107

6 - 21
Code 128 Function Code Transmit
By default, Code 128 function codes are not transmitted with Code 128 bar 
code data.  However, if you wish to transmit Code 128 function codes with the 
bar code data, scan the Function Codes On bar code, below.  Default = Off
Te l e p e n

Code 128 Code Page
* Function Codes Off
Function Codes On 

Page 108

6 - 22
Te l e p e n
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 
and decodes them as standard full ASCII (start/stop pattern 1).  When Original 
Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 
and decodes them as compressed numeric with optional full ASCII (start/stop 
pattern 2).  Default = AIM Telepen Output.
On
*  Off
Original Telepen Output *AIM Telepen Output 

Page 109

6 - 23
Telepen Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 1-60.   Minimum Default = 1, Maximum Default = 60.
Minimum Message Length
Maximum Message Length 

Page 110

6 - 24
UPC A

UPC A
UPC A Check Digit
This selection allows you to specify whether the check digit should be transmit-
ted at the end of the scanned data or not.  Default = On.
*  On
Off
*  On
Off 