Page 191
Engine Hose Connections: FAST IDLE THERMOVALVE (A/T onlyl IDLE AIR CONTROLIIAC}VALVE TEF BYPASSHOSE THERMOSTATHOUSING CONNECTINGPIPE VALVE HOSES 10-3 www.emanualpro.com
Page 192
Radiator 1. 2. 3. 4. Replacement CONDENSERFAN,/SHROUDASSEMBLY Drain the engine coolant. Remove the upper and lower radiator hoses, and ATF cooler hoses. Disconnect the fan motor connector. Remove the radiator upper bracket, then pull up the raotalor, 5. Remove the fan shroud assemblies and other parts from the radiator. 6. lnstall the radiator in the reverse order of removal. NOTE: . Set the upper and lower cushions securely. . Fill the radiator with engine cooiant and bleed the air. RADIATOR CAP...
Page 193
Engine Coolant Refilling and Bleeding 1. Slide the heater lemperature control lever to maxi mum heat. Make sure the engine and radiator are cooi to the touch. 2. Remove the radiator caP. 3. Loosen the drain plug, and drain the coolant. 4. Remove the drain bolt from the cylinder block. DRAIN PLUG DRAIN BOLT78 N.m {8.0 ksl.m, 58 lbtft} 10-5 6. 7. Apply liquid gasket to the drain bolt threads, then reinstall the bolt with a new washer and tighten it securely. Tighten the radiator drain plug securely....
Page 194
Radiator Engine Coolant Refilling and Bleeding (contdl Mix the recommended antifreeze with an equal amount of water in a clean container. NOTE: . Always use Genuine Honda Antifreeze/Coolant. Using a non-Honda coolant can result in corro-s\on, ca sng t\e coo\ g sys\em \o ma\lunct\on o. fail. For best corrosion protection, the coolant con- centration must be maintained year-round at50% minimum. Coolant concentrations less than 50% may not provide sufficient protection against corrosion or freezing....
Page 195
Cap Testing 1. 2. Remove the radiator cap, wet its seal with engine coolant, then install it on the pressure tester. Apply a pressure of 93 - 123 kPa (0.95 - 1.25 kgflcm, 14 - 18 psi). Check for a drop in pressure. lf the pressure drops, repiace the cap. RADIATOR PNESSURE TESTER lCommercially available) 3. RADIATOR ADAPTOR(for 32 mm neck, low Profile) 2. 3. Testing 1.Wait until the engine is cool, then carefully remove the radiator cap and fill the radiator with engine coolant to the top oI the filler...
Page 196
Thermostat Replacement THERMOSTAInstall with pin up. THERMOSTATHOUSING RUBBER SEALReplace. RADIATOB FANswtTcH24 N.m {2.4 kgtm, l7 lbt.ftl THERMOSTATCOVER 12 N.m (1.2 kgl.m,8.7 tbtftl 6 x 1.0 mm 10-8 www.emanualpro.com
Page 197
Testing Replace the thermostat if it is open at room temperature. To test a closed thermostat: 1. Suspend the thermostat in a container of water. Do not let the thermometer touch the bottom of the hot container. THERMOMETER THERMOSTAT Heat the water, and check the temperature with a thermometer. Check the temperature at which the thermostat first opens, and at which it is fully open. Measure the lift height of the thermostat when fully open. STANDARD THERMOSTAT Lift height: above 8.0 mm (0.31 in) Starts...
Page 198
Water Pump lllustrated Index ENGINE COOLANTTEMPERATURE IECTISENSOR18 N.m 11,8 kgt.m,13 tbt.ftl COOLANTTEMPERATUREGAUGEUNIT 6x1.0mm9.8 Nm (1.0 kgf.m,7.2 tbt frl 9 N.m {0.3 kgf.m,7 tbf.fttApply liquid gasketto the threads. WATER OUTLETCOVERApply liquid gasker part No.08718 - 0001 or 08718 - 0003to the mating surface. RADIATOR FAN SWITCH2il N.m (2.i1 kgl.m,17 tbfft) WATER PUMPlnspection, page 10-11 O-RINGReplac€. 6xl,0mm12 N.tn n.2 lgl.rn,8.7 tbfft) CONNECTINGPIPE 6x1.0mm12 N.m 11.2 kgf.m,8.7 tbtftl 10-10...
Page 199
Inspection 1. 2. Remove the timing belt (see section 6) Turn the water pump pulley counterclockwise. Check that it turns freely. Check for signs of seal leakage. NOTE: A small amount ol weeping from the bleed hole is normal. BIIED HOLE Replacement 1. Remove the timing belt (see section 6). 2. Remove the water pump by removing five bolts 3, Inspect, repair and clean the O-ring groove and the mating surface with the cylinder block. Replace.6x1.0mmt2 N.m 11 2 kgf m. 8.7 tbf.ftl 4. lnstall the water pump in...
Page 200
Fan Control Component Location Index UNDEB.HOODFUSE/RELAY BOX RADIATOR FAN RELAYTest, see section 23 BADIATOR FAN Removal, page 10-10Test, page 10-14 BADIATOR FAN MOTORRemoval, page 10-2 CONDENSERFAN MOTOR ftflEffltrlt lrt r-1 a-l @u!lfl]l 10-12 www.emanualpro.com