Page 31
31 Operating • The projector may ignore operation by buttons while moving the lens. • You can perform the LOAD function using LENS MEMORY button.NOTE Adjusting the lens (continued) This projector is equipped with memory functions for the lens adjustments (LENS SHIFT and LENS TYPE). Up to 3 sets of adjustments can be stored. To utilize the lens memory feature, press the POSITION or FUNCTION button while the LENS SHIFT dialog is displayed. Then the LENS MEMORY dialog will ap- pear. The current lens...
Page 32
32 Operating 1. Press POSITION button on the remote control when no menu is indicated. The “POSITION” indication will appear on the screen. Adjusting the position 2. Use the ▲/▼/◄/► cursor buttons to adjust the picture position. When you want to reset the operation, press RESET button on the remote control during the operation. To complete this operation, press POSITION button again. Even if you do not do anything, the dialog will automatically disappear after a few seconds. 1. Press AUTO button on...
Page 33
33 Operating AUTO: performs the automatic vertical keystone correction. ( 57) MANUAL: allows you to adjust the vertical and horizontal keystone. PERFECT FIT: allows you to adjust each of the screen corners to correct the distortion. • The menu or dialog will automatically disappear after several seconds of inactivity. Press the KEYSTONE button again, or point the cursor at EXIT in the dialog and press the ►or ENTER button to end the operation and close the menu or dialog. • When the screen...
Page 34
34 Operating PERFECT FIT: When PERFECT FIT is pointed at, pressing the ► or ENTER button displays the KEYSTONE_ PERFECT FIT dialog. This projector is equipped with a test pattern for PERFECT FIT. Select the test pattern icon shown in the lower left of the dialog with the ◄/▼ buttons. When you press the ENTER or INPUT button, the test pattern appears or disappears. 1. If it is necessary to initialize the current adjustment, point at RESET in the dialog with the RESET button, and press...
Page 35
35 Operating Correcting the distortion (continued) 4. This projector is equipped with a memory feature for PERFECT FIT adjustment. Up to 3 sets of adjustments can be stored. ● SAVE: To store the current PERFECT FIT adjustment, select one of the SAVE icons numbered 1 to 3 (number of the memory) with the ◄ /▲/▼ buttons and press the ENTER or INPUT button. Remember that the current data being stored of a memory will be lost by saving new data into the memory. ● LOAD: To recall stored...
Page 36
36 Operating 1. Using the magnify feature 2. 3. 4. Press the MAGNIFY ON button on the remote control. The picture will be magnified, and the MAGNIFY dialog will appear on the screen. When the MAGNIFY ON button is pressed for the first time after the projector is turned on, the picture will be zoomed by 1.5 times. On the dialog, triangle marks to show each direction will be displayed. The display magnification of the projector switches in order with every press of the MAGNIFY ON button. For...
Page 37
37 Operating 1.Press the SHADE button on the control panel. The mechanical lens shade closes and the screen turns to black. The SHADE indicator on the projector blinks in yellow while the shade is closed. To open the shade and restore the screen, press the SHADE button again. Temporarily shading the screen • The projector will turn off automatically when the time set up by the SHADE TIMER passes (70). • When turning off the power by the normal procedure, the lens shade opens automatically. If...
Page 38
38 Operating The PbyP / PinP is a function for displaying two different picture signals on a screen that is separated into main and sub areas for each signal. PbyP (Picture by Picture) / PinP (Picture in Picture) PbyP button • If the LAN or USB TYPE A / B port is selected when the PbyP button is pressed, input from other port is displayed on the main area. • When in the PbyP / PinP mode, use the MENU button on the remote control or ▲/▼ buttons on the control panel to display the OSD menu. • There...
Page 39
39 Operating PbyP (Picture by Picture) / PinP (Picture in Picture) (continued) The position of the main area can be toggled with the ◄/► buttons when the setting information is displayed on the screen. The yellow frame and the audio mark will move together with it. Changing the main area main areasub areamain area sub area The setting information will be appeared for several seconds when the PbyP / PinP function is started. Displays the input information for each area. A yellow frame around...
Page 40
40 Operating Press any button to select an input port on the remote control or press the INPUT button on the control panel. A dialog box to select the input signal for the main area will be displayed. Choose a signal using the ▲/▼ buttons. To change the signal in the sub area, switch temporarily across to the main area with the ◄/► buttons. Displaying the same signal on the both areas is not allowed. Refer to the table for details on available input signal combinations. Any combinations marked...