4 3. Management with Web browser software 3.6 Command Control via the Network (continued) When the authentication setting is enabled, the following settings are required. (25) 7) Click [Security Settings] on the main menu. 8) Click [Network Control] and enter the desired authentication password. * See NOTE. 9) Click [Apply] button to save the settings. • The Authentication Password will be the same for Network Control Port1 (Port: 23), Network Control Port2 (Port: 9715), and Image Transfer Port (Port: 9716). • The new configuration settings are activated after restarting the network connection. When the configuration settings are changed, you must restart the network connection. You can restart the network connection by clicking [Network Restart] on the main menu. NOTE
4 3. Management with Web browser software 3.6 Command Control via the Network (continued) Command Format Command formats differ among the different communication ports. ● TCP #23 You can use the RS-232C commands without any changes. The reply data format is the same as the RS-232C commands. However, the following reply will be sent back in the event of authentication failure when authentication is enabled. HeaderData lengthRS-232C commandCheck sumConnection ID 0x020x0D 3 bytes byte byte ReplyError code 0x1F0x040x00 Header → 0x02, Fixed Data length → RS-232C commands byte length (0x0D, Fixed) RS-232C commands → RS-232C commands that start with 0xBE 0xEF (13 bytes) Check Sum → This is the value to make zero on the addition of the lower 8 bits from the header to the checksum. Connection ID → Random value from 0 to 255 (This value is attached to the reply data) ● TCP #9715 Send Data format The following formatting is added to the header (0x02), Data length (0x0D), Checksum (1byte) and Connection ID (1 byte) of the RS-232C commands.
43 Reply Data format The connection ID (the data is same as the connection ID data on the sending data format) is attached to the RS-232C commands reply data. ReplyConnection ID 0x06 byte ReplyConnection ID 0x15 byte ReplyError codeConnection ID 0x1C bytes byte ReplyDataConnection ID 0x1D bytes byte ReplyStatus codeConnection ID 0x1F bytes byte 3. Management with Web browser software 3.6 Command Control via the Network (continued) ReplyAuthentication Error codeConnection ID 0x1F0x040x00 byte
44 3. Management with Web browser software 3.6 Command Control via the Network (continued) Automatic Connection Break The TCP connection will be automatically disconnected after there is no communication for 30 seconds after being established. The projector does not accept commands without authentication success when authentication is enabled. The projector uses a challenge response type authentication with an MD5 (Message Digest 5) algorithm. When the projector is using a LAN, a random 8 bytes will be returned if authentication is enabled. Bind this received 8 bytes and the Authentication Password and digest this data with the MD5 algorithm and add this in front of the commands to send. Following is a sample if the Authentication Password is set to “password” and the random 8 bytes are “a572f60c”. Authentication 1) Select the projector. 2) Receive the random 8 bytes “a572f60c” from the projector. 3) Bind the random 8 bytes “a572f60c” and the Authentication Password “password” and it becomes “a572f60cpassword”. 4) Digest this bind “a572f60cpassword” with MD5 algorithm. It will be “e3d97429adffa11bce1f7275813d4bde”. 5) Add this “e3d97429adffa11bce1f7275813d4bde” in front of the commands and send the data. Send “e3d97429adffa11bce1f7275813d4bde”+command. 6) When the sending data is correct, the command will be performed and the reply data will be returned. Otherwise, an authentication error will be returned. • As for the transmission of the second or subsequent commands, the authentication data can be omitted when the same connection. NOTE