SVR 5210TL-130500-1001
CP85E3.4.5 The Central Processor Unit card contains an INTEL 8085
FB-17288-Amicroprocessor and associated clock, control, interrupt, and I/O
(InpuVOutput) interface circuits. The 8085 microprocessor
provides both normal switching and MDR functions. The card
controls all operations within the system including:
l Path connect/disconnect within the network
* Data transfer to/from system maintenance terminals
l Data transfer to/from system disk drive
l Communications to/from system...

Page 422

TL-130500-1001FMSD3.4.8 The File Management System Data card provides an
FB-17220-BOAintelligent serial data interface between the floppy disk drive, the
hard disk drive, the PD-200’s ADMP, and the CPU. Data and
control signals are cable-connected between the floppy disk
drive and FMSD. The FMSD is addressed via the CPU address
bus. Data is transferred between the CPU and the FMSD via the
CPU data bus. This card provides DMA (Direct Memory Access)
and interrupt control to the CPU.
The FMSD contains the...

Page 423

TL-130500-1001iNCl&3.4.11 The Synchronizable Intermediate Network Clock
FB-20922-A
card (Figure 3.5) provides the basic timing pulses to the system
network and PCM associated circuitry. The INCKS card permits
the system to communicate over 
Tl trunks. In this case, the
system is slaved to the far end of the span. The INCKS card
also contains the network time slot counter.
The INCKS card receives control inputs from, and outputs clock
pulses to, the EPCMN card.
USE CABLE
CONNECTOR0 ONLY FOR 
ySITHIS...

Page 424

TL-130500-1001
INCK
FB-20771 -lA3.4.12 The Intermediate Network Clock card provides all the
functions of the INCKS card, except that Tl’ synchronization is not
possible. This card is used if no Tl functions are used in the
system.
NOTE: Use FB-20922 network clock when network timing is
derived from a 
Tl span (slave operation).
PCMFSFB-17189-A
PCMIFB-17187-A
S-463.4.13 Each 48 channels in the system requires one Pulse Code
Modulation Frame Synchronization card. The PCMFS provides
frame synchronization...

Page 425

PCMTS
FB-20974-A
FD-1070-AY(full height)Hard Disk Assembly
FD-1070-BD
(half height)FD-1070-BA
Floppy Disk Assembly
SVR 5210TL-130500-1001
3.4.15 The Pulse Code Modulation Tone Source card stores
samples of the various system tones within a ROM (Read-Only
Memory). Tones read from ROM are transferred to the
information memories for use throughout the system. This
provides the dial tone, 
ringback tone, and other alerting tones
used in the system.
The PCMTS receives control inputs from the Network Clock...

Page 426

TL-130500-1001Digital Trunking3.5 This paragraph provides information about PCBs that are
Printed Circuitinstalled within the Tl span digital trunk preferred location.
BoardsIn this system, only one Tl span, which has a maximum of 24
channels, can be installed. Only file X can be used for this type
of configuration and only certain slots within that file can be used
by these cards. Not all 
Tl span cards require two card slots.
Card slots C6, 
C5, and C4 may be used even if a Tl span is
implemented....

Page 427

TL-4 30500-l 901Table 3.2 
Tl Span Cards
Card Number Mnemonic and NameCard SlotFB-15278-A, FDC, Frame Detector Card
iX/l0iFB-15280-A, LCM, Line Compensator Card1 x/12
/  FB-17277-A or FB-15277-1, SIL, Span Interface Card
Ixi14II  FB-20718-l A, 
Tl S, 11 -Type Supervisory Card
IX/16(  FB-17192-A, 
Tl B2, Tl Buffer CardXl18SVR 5210
FDC3.51 The Frame Detector card is required for the Tl span and
FB-15278-Aprovides the following functions:
* Monitors for errors in framing synchronization patterns
e Generates...

Page 428

TL-130500-1001
NOTE: To synchronize the PABX digital network timing to theTl -span timing, use FB-15277-l.
s-50USE CABLE
CONNECTOR 0 
-ONLY FOR S I
SINX 0
SINX 1
F&l 5277-IASPAN INTERFACE
CARD HANDLE
Figure 3.7SIL Card Handle View
TlS3.5.4 The Tl-Type Supervisory card is required for the Tl
FB-20718-1Aspan. It provides a supervisory signal interface between the
system and the 
Tl span. The buffers on the TlS card retain the
status of sense and control points.
The 
TlS card has a program board which can...

Page 429

SW 5210TL-130500-1001
l Remote alarm (REM) lamp that lights when the second bit of
an incoming bipolar stream is inhibited for 1.32 to 1.44
seconds.
l System alarm (SYS) lamp that lights when any alarm condition
exists, including when the system is fully frame-synchronized
but in a loop mode.
l Remote power failure alarm (RPF) lamp that lights when a
power failure occurs in the office-terminating shelf.
l Alarm cutoff (ACC) lamp that lights when the alarm cutoff
switch and the loop test switch are...

Page 430

TL-130500-1001
RED
INDICATORLAMPSFB-2071 B-A
LOC
IOREM0
SYS0
RPF
,O
AC00
AC0
9
LP
ON
LPTRED
/INDICATORLAMP
FB-20718-1ATl-TYPE
SUPERVISORY
CARD HANDLE
L
Figure 3.8
TlS Card Handle View
TlB23.55 The Tl Buffer card is required for the Tl span. It provides
FB-17192-Aa buffer between the incoming PCM data from the Line
Compensator card and the digital time-switch network in the
system. 
It also buffers the outgoing PCM data from the digital
time-switch network to the Span Interface card. It will
synchronize...