Page 421
SVR 5210TL-130500-1001 CP85E3.4.5 The Central Processor Unit card contains an INTEL 8085 FB-17288-Amicroprocessor and associated clock, control, interrupt, and I/O (InpuVOutput) interface circuits. The 8085 microprocessor provides both normal switching and MDR functions. The card controls all operations within the system including: l Path connect/disconnect within the network * Data transfer to/from system maintenance terminals l Data transfer to/from system disk drive l Communications to/from system...
Page 422
TL-130500-1001FMSD3.4.8 The File Management System Data card provides an FB-17220-BOAintelligent serial data interface between the floppy disk drive, the hard disk drive, the PD-200’s ADMP, and the CPU. Data and control signals are cable-connected between the floppy disk drive and FMSD. The FMSD is addressed via the CPU address bus. Data is transferred between the CPU and the FMSD via the CPU data bus. This card provides DMA (Direct Memory Access) and interrupt control to the CPU. The FMSD contains the...
Page 423
TL-130500-1001iNCl&3.4.11 The Synchronizable Intermediate Network Clock FB-20922-A card (Figure 3.5) provides the basic timing pulses to the system network and PCM associated circuitry. The INCKS card permits the system to communicate over Tl trunks. In this case, the system is slaved to the far end of the span. The INCKS card also contains the network time slot counter. The INCKS card receives control inputs from, and outputs clock pulses to, the EPCMN card. USE CABLE CONNECTOR0 ONLY FOR ySITHIS...
Page 424
TL-130500-1001 INCK FB-20771 -lA3.4.12 The Intermediate Network Clock card provides all the functions of the INCKS card, except that Tl’ synchronization is not possible. This card is used if no Tl functions are used in the system. NOTE: Use FB-20922 network clock when network timing is derived from a Tl span (slave operation). PCMFSFB-17189-A PCMIFB-17187-A S-463.4.13 Each 48 channels in the system requires one Pulse Code Modulation Frame Synchronization card. The PCMFS provides frame synchronization...
Page 425
PCMTS FB-20974-A FD-1070-AY(full height)Hard Disk Assembly FD-1070-BD (half height)FD-1070-BA Floppy Disk Assembly SVR 5210TL-130500-1001 3.4.15 The Pulse Code Modulation Tone Source card stores samples of the various system tones within a ROM (Read-Only Memory). Tones read from ROM are transferred to the information memories for use throughout the system. This provides the dial tone, ringback tone, and other alerting tones used in the system. The PCMTS receives control inputs from the Network Clock...
Page 426
TL-130500-1001Digital Trunking3.5 This paragraph provides information about PCBs that are Printed Circuitinstalled within the Tl span digital trunk preferred location. BoardsIn this system, only one Tl span, which has a maximum of 24 channels, can be installed. Only file X can be used for this type of configuration and only certain slots within that file can be used by these cards. Not all Tl span cards require two card slots. Card slots C6, C5, and C4 may be used even if a Tl span is implemented....
Page 427
TL-4 30500-l 901Table 3.2 Tl Span Cards Card Number Mnemonic and NameCard SlotFB-15278-A, FDC, Frame Detector Card iX/l0iFB-15280-A, LCM, Line Compensator Card1 x/12 / FB-17277-A or FB-15277-1, SIL, Span Interface Card Ixi14II FB-20718-l A, Tl S, 11 -Type Supervisory Card IX/16( FB-17192-A, Tl B2, Tl Buffer CardXl18SVR 5210 FDC3.51 The Frame Detector card is required for the Tl span and FB-15278-Aprovides the following functions: * Monitors for errors in framing synchronization patterns e Generates...
Page 428
TL-130500-1001 NOTE: To synchronize the PABX digital network timing to theTl -span timing, use FB-15277-l. s-50USE CABLE CONNECTOR 0 -ONLY FOR S I SINX 0 SINX 1 F&l 5277-IASPAN INTERFACE CARD HANDLE Figure 3.7SIL Card Handle View TlS3.5.4 The Tl-Type Supervisory card is required for the Tl FB-20718-1Aspan. It provides a supervisory signal interface between the system and the Tl span. The buffers on the TlS card retain the status of sense and control points. The TlS card has a program board which can...
Page 429
SW 5210TL-130500-1001 l Remote alarm (REM) lamp that lights when the second bit of an incoming bipolar stream is inhibited for 1.32 to 1.44 seconds. l System alarm (SYS) lamp that lights when any alarm condition exists, including when the system is fully frame-synchronized but in a loop mode. l Remote power failure alarm (RPF) lamp that lights when a power failure occurs in the office-terminating shelf. l Alarm cutoff (ACC) lamp that lights when the alarm cutoff switch and the loop test switch are...
Page 430
TL-130500-1001 RED INDICATORLAMPSFB-2071 B-A LOC IOREM0 SYS0 RPF ,O AC00 AC0 9 LP ON LPTRED /INDICATORLAMP FB-20718-1ATl-TYPE SUPERVISORY CARD HANDLE L Figure 3.8 TlS Card Handle View TlB23.55 The Tl Buffer card is required for the Tl span. It provides FB-17192-Aa buffer between the incoming PCM data from the Line Compensator card and the digital time-switch network in the system. It also buffers the outgoing PCM data from the digital time-switch network to the Span Interface card. It will synchronize...