    DICOM Worklist Preset Parameter Descriptions: 
    Max. Result Specify the maximum number of patient records you 
    want the system to retrieve when searching the patient database. 
    Search Criteria Displays the Search Criteria window, where you can 
    enter search parameters for the system to use when searching the 
    patient database. 
    DICOM Worklist Search Criteria Preset Parameter Descriptions: 
    Select Search Criteria to Add Select the type of information that you 
    want to define for search parameters. The following searches are 
    allowed: Patient Name, Patient ID, Modality, Scheduled Procedure 
    Start Date, Start Time, and End Time. 
    Tags (at least one) The name of a tag selected to use for search 
    criteria. 
    Properties: Value Type the value of the Selected Tag item. For 
    example, if you select Referring Physician’s Name in the Select Tag 
    field, you can enter the name of the physician in the Value field. 
    Properties: Don’t Use Select to turn off the selected search criteria. 
    To exclude a tag from the worklist query, select Don’t Use and then 
    select Add to List. 
    Add Select to add the tag and value to the list of search criteria. 
    Remove Select to remove the tag and value from the list of search 
    criteria. 
    Clear Clears all tags.  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 35 
    Standard Print 
     
    Standard Print Preset Parameter Descriptions: 
    Printer Select the printer. 
    Rows Specify Range: 1-5. 
    Columns Specify Range: 1-5. 
    Orientation Specify Landscape/Portrait 
    Top Margin (mm) Specify the top margin Range: 0-51mm 
    Bottom Margin (mm) Specify the bottom margin Range: 0-51mm 
    Left Margin Specify the left margin Range: 0-51mm 
    Right Margin Specify the right margin Range: 0-51mm 
    Video Capture 
    Video Capture Preset Parameter Description: 
    Type Specify Color, BW, or DVD Record/Pause. 
    Save As 
    Save As Preset Parameter Description 
    Destination Specify destination device, Hard Drive or USB Flash 
    Drive. 
     
      
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 36 
    Dataflow 
    A dataflow is a set of pre-configured services. When you select a 
    dataflow, the ultrasound system automatically works according to the 
    services associated with the dataflow. The Dataflow tab allows you to 
    select and review information about dataflows. You can also create, 
    change, and remove dataflows. 
     
    Dataflow Preset Parameter Descriptions: 
    Name Select the dataflow from the list. 
    Direct Store Select to store data directly to archive (no buffer 
    storage). 
    Hidden Select so that this dataflow does not appear as a Dataflow on 
    the Patient menu. 
    Default Dataflow This dataflow will be the default when the system is 
    initially booted.  
     
    Key Object Selection: Image Deletion Notification Image Deletion 
    Notification is available ONLY for the Direct Store Workflow and only 
    generated when there are images deleted during the exam. This lets 
    the reader at the PACS system know which images have been 
    deleted. An indicator is placed on deleted images with a reason, 
    “Rejected for Quality Reasons,” for example. 
    Print Button Setup 
    To configure the print buttons: 
    First select the print button to configure under Physical Print Buttons 
    on the upper, left corner of the button tab. Then select the device 
    you want to add in the middle part of the page, under Available 
    Input/ Outputs. Then click on the right arrow in the top right corner 
    of the page. You can configure each print key to multiple output 
    devices/dataflows. 
    Note: You must be logged 
    on as Administrator to use 
    the Dataflow tab. 
    You can only attach one 
    DICOM service per print 
    key (e.g., PACS and 
    DICOM printer). Multiple 
    DICOM devices should be 
    configured as a dataflow  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 37 
     
     
    Button Preset Parameter Descriptions: 
    Format RawDICOM, DICOM, or M&A. 
    Image Frames Single (captures a DICOM single frame image), Multiple 
    (captures a DICOM multi-frame, CINE) -- only select this if the PACS 
    server supports multi-frame, and Secondary Capture (forces all 
    DICOM images to Secondary Capture). 
    Capture Area For use with Secondary Capture: Video Area, Image 
    Area or Whole Screen. 
    Compression Select the compression type: None, Rle, Jpeg, or 
    Jpeg2000. 
    Active Images Page Lets you send to a Windows-based printer. 
    Single Association Only visible with DICOM image storage 
    destinations. When selected, the spooler sends multiple images in 
    one store job. 
    Removable Media  
    The Removable Media tab allows you to: 
     Verify the DICOM directory on removable media. 
     Determine the free space capacity of the media. 
     Determine if the media is finalized or unfinalized. 
     Determine if the media is formatted or unformatted. 
     Format removable media (rewritable CD/DVD or USB device). 
     
    Note: When using a print 
    key to send an image 
    directly to a DICOM 
    device, this causes a single 
    DICOM association per 
    image. Most devices (all 
    known printers) work fine 
    with this. However, some 
    storage devices, such as 
    ALI, Kodak Access, and 
    Cemax, assume that the 
    end of each association is 
    the end of the exam and 
    can result in a new folder 
    for each image. In the 
    Utility menu, select a 
    single association or open 
    PR for the desired DICOM 
    storage device.  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 38 
    Verify Select to verify DICOM directory on removable DICOM 
    disk. 
     Verify the free space of the media. 
     Verify that the media is finalized or unfinalized. 
     Verify that the media is formatted or unformatted. 
    Format Select to format removable media. 
    Quick Format Check this box to format the media quickly,  If you 
    uncheck this box, the media is formatted with a full format. New 
    media should always be formatted with a full format. 
    Removable Media Select the removable media to format or verify. 
    Label Type a label for a new removable media (free text). 
    Formatting Removable Media 
     Select the removable media from the Media list. 
     Type a name for the removable media in the Label field. 
     Do not use any of the following characters for labelling: 
    \ / : ; . , * < > | + = [ ] 
     Select Format. Confirm OK or Cancel. An information window 
    confirms when the format has been completed. Select OK to exit. 
    Miscellaneous 
    The Miscellaneous tab allows you to configure system behavior 
    related to patient management and print and store options.  
     
    You can specify default system functionality, such as whether patient 
    ID is required when you archive data, or if the system should 
    automatically search the archive for a patient when you enter patient 
    data. 
    Note: Select Full Format 
    (do not check Quick 
    Format box) when 
    formatting a new MOD 
    for the first time  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 39 
     
     
    Patient/Exam Menu Options Preset Parameter Descriptions: 
    Use birthdate  
    In the Patient information window enter either the patient age or the 
    birth date: When selected, enter birth date, then the age is 
    calculated. When cleared, enter age (birth date field not available). 
    Auto search for patient  
    In the Search/Create Patient window: When selected, the system 
    automatically searches through the selected patient archive, while 
    the user enters patient information. When cleared, the automatic 
    search tool is turned off. If you are trying to keep the past patient 
    data confidential, DO NOT use this feature. 
    Automatic generation of patient ID 
    In the Search/Create Patient window: When selected, the Patient ID is 
    not required when entering a new patient in the archive. The system 
    automatically generates an ID number. When cleared, the Patient ID 
    is required when entering a new patient in the archive. 
    Auto Archiving patient data Archives patient data automatically. 
    After [End Current Patient], go to: Select Worklist screen or Patient 
    screen. 
    Keep Search String Search string is kept rather than cleared. 
    Worklist Auto Query Automatically queries the worklist server. 
    Show BBT Show BBT field on the OB patient screen to input the basal 
    body temperature. 
    Double Click on Patient List to Start Select Review or New Exam to 
    display each time you double click on the patient name in the patient 
    list on the Patient menu. 
    If you are trying to keep 
    the past patient data 
    confidential, DO NOT use 
    this feature.  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 40 
    Detail Mode Select to display Detail Mode, rather than Exam View, 
    when you select the patient name in the patient list on the Patient 
    menu. You can also type comments while in Detail Mode. 
    Export to USB HDD: Create DICOMDIR Create DICOMDIR is a DICOM 
    file format which contains how the directory and DICOM files 
    structured for diagnostic portable media behave. It is important for 
    portability between the LOGIQ E9 to PACS.  
    Automatic Disable Patient Data 
    Select to automatically disable patient data. 
    If selected, locks the patient name, date of birth and gender (like 
    Patient ID). The Factory Default for this preset is unchecked. 
     
    Remember Cursor Position on the Transfer Screen 
    To set a default cursor location on the Data Transfer screen: 
     Select the “Remember cursor position in the Transfer screen” 
    preset and press Save. 
     On the Data Transfer screen, move the cursor to the desired 
    field. 
     Exit out of the Data Transfer screen. When returning to the Data 
    Transfer screen, the cursor is located in the selected position. 
    Request acknowledge of End Exam action When selected, the user is 
    asked to confirm action when ending an examination. Warn Image 
    Store without Patient Select to receive a warning when you press the 
    Print key without an active patient. 
    Warn Register to No Archive Select to receive a warning when you 
    register a patient to the “No Archive” data flow. Select a different 
    data flow for permanent storage of patient data. 
    Warn image store to Read Only dataflow The system posts a warning 
    message if you attempt to store images to a read-only Dataflow. 
    Warn video titles exist in the internal storage The system posts a 
    warning if the video titles exist on the internal DVR flash memory. 
     
    Examination list window column configuration 
    You can create new columns, remove columns, and select the 
    information to display in a column. 
     Move the Trackball to highlight a column. 
     Press Set. 
    Use the arrows (>) to reposition column headings. 
    If you want to save exams 
    to the USB Hard drive and 
    look at it on the PACS, the 
    DICOMDIR is a must.  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 41 
    Print and Store Options Preset Parameter Descriptions 
    P [1-4] Key Sound Select None, Click, Chimes, Ding, Ding-Dong, or 
    Whoosh. 
    Store Dual as Dicom Only Select to always store dual images as a 
    DICOM (secondary capture) store, rather than as Raw DICOM. 
    Dual When Color Support is Mixed Dataflow Mixed is not available.  
    While transferring dual images to the PACS, send black and white 
    images as gray; send color images as color. Set up 2 services (one gray 
    and one color), set up 2 dataflows, and set up 2 buttons. Each button 
    needs to be tied to a different service. 
    Store Multiframe for Sec Capture Loops Select if you want the CINE 
    loop stored as a secondary capture. 
    Enable Smart Capture Area Check box to select. 
    Store 2D Loop with Timeline Data Check box to select. 
    Patient List Print-Font Size Select font size. 
    DICOM Multi-Frame image resolution Select Default, Medium, or 
    Large for recalled DICOM Multi-frame Frame Cine loops. 
    Show progress bar while storing image Select to display progress bar 
    during image storage. 
    Image Order Scheme Select to Direct Store images in Acquisition 
    Order, Scan Assistant Order, or Off. 
     Off. The clipboard on the Ultrasound system shows the image in 
    the order it was acquired. Therefore, re-stored images appear 
    where you’d expect. :owever, on the PACS system, images 
    appear in arrival order or in image number order. 
     Acquisition Order. From the Ultrasound system perspective, the 
    same as “Off.” But on the PACS system (if based on image 
    number order), images are displayed consistently with the way 
    they are stored on the Ultrasound sysdtem. 
     Scan Assistant Order. You can define the storage order (reading 
    order) via Scan Assistant Creator. Therefore, based on the order 
    defined in Scan Assistant, images are re-ordered and displayed in 
    this manner both on the Clipboard and on the PACS system. 
    Other ID Options Preset Parameter Descriptions: 
    Enable Other ID “Not selected” is the Default. If selected, allow 
    entering Other ID, such as Citizen Service Number, Burger Service 
    Number (BSN), National Health System (NHS) number, along with 
    patient ID information on the Patient Screen. 
    Validation Format If the Enable Other ID preset is selected, the 
    system validates the format of “Other =D” when an =D is entered. 
    Select if you want to keep 
    the user preset for Color 
    Photometric 
    Interpretation while in 
    Dual mode.  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 42 
    Choose: NHS Number *** ** *****, Letters and Numbers, Numbers, 
    or Any (no restriction)  
    						
    							 GE Logiq E9/Vivid E9 Training Manual 
    © 2016 Conquest Imaging 43 
    Module 5 Preventive Maintenance 
    Preventive maintenance procedures are very important in a clinical 
    setting. Be sure to follow the health care facilities documentation 
    procedures. 
    System Backup 
    System backup is very important. Backup the system anytime you are 
    in front of it! Your backup is not complete without printouts!  
    The Backup/Restore function enables the user to: 
     Copy/Restore the patient archive. 
     Copy/Restore the system configuration. 
    The Copy/Restore system configuration feature enables the user to 
    configure several units with identical presets, providing that the units 
    have the same software version. 
    Backup Procedure for Vivid E9  
    To create a backup on Vivid E9 systems you must first login as 
    admininstrator. You can log on to Vivid E9 as ‘ADM’ either using the 
    touch screen or the keyboard.  
    Touch Screen: Select UtilityConfig 
    Keyboard: Press F2. 
    Both will bring up the Operator Login dialog box. By default, two 
    users are pre-defined, USR and ADM. If you log on as USR, you will 
    have access to do user set-up tasks such as select a printer. 
    If you log on as ADM, you will have access to do general set-up and 
    service adjustments such as network and connectivity settings. The 
    default password for ADM is ulsadm. Select ADM and enter the 
    password (ulsadm) and select Login. 
    The Backup/Restore function enables the user to: 
    To minimize accidental 
    loss of data, perform 
    backup of the patient 
    archive stored on the local 
    hard drive at least once a 
    week. 
    USR requires no password 
    by system default. 
    However, the facility may 
    have set up individual 
    passwords for different 
    users in which case you 
    will have to ask for a 
    password  
    						