Page 441

Presets and System setup
Vivid7/Vivid7 PRO Users Manual427
FC092326-03
RemoteArch-RemoteHD Remote archive remote harddrive
A remote database (either on 
EchoPAC workstation or on 
EchoServer) is used for patient 
archiving. Images are stored to a 
network image volume (either 
internal HD on EchoPAC workstation 
or EchoServer volume).
Remote Archive - Remote 
HD/DICOM ServerA remote database is used for 
patient archiving. Images are stored 
to a network image volume and to a 
DICOM server.
This dataflow...

Page 442

Presets and System setup
428Vivid7/Vivid7 PRO Users Manual
FC092326-03
Worklist/Remote Archive 
- Remote StorageThis dataflow is used in a network 
environment that includes Vivid HL7 
Gateway. The patient list in the 
Search/Create Patient window is 
coming from Vivid HL7 Gateway 
through DICOM Modality Worklist. 
All patient data and images are 
stored to EchoServer.
Raw DICOM MODRaw image format to/from a DICOM 
Magneto Optical Disk
Read/Write images in raw format 
from/to a DICOM formatted 5.25...

Page 443

Presets and System setup
Vivid7/Vivid7 PRO Users Manual429
FC092326-03
To select the default dataflow
1. Select the dataflow in the Name drop-down menu. (see 
Figure 12-14).
2.Check the Default box.
The dataflow will be selected by default when restarting 
the unit.
3.Check the Direct Store box to have data stored 
automatically to the archive (no buffer storage).
To create a new dataflow
1. Press Add.
The Add dataflow window is displayed.
 Figure 12-15: The Add dataflow window
2. Enter a name for the...

Page 444

Presets and System setup
430Vivid7/Vivid7 PRO Users Manual
FC092326-03
Adjusting the assigned devices
1. Select the device in the Selected devices field.
2. Press Properties.
The Properties window is displayed.
3. Adjust the device specific parameters as desired (see table 
below). Not all the settings listed below apply to all devices.
General settings Definition
Name Free text: give a descriptive name for the device.
IP address Select from drop-down menu
Database Name Automatically selected according...

Page 445

Presets and System setup
Vivid7/Vivid7 PRO Users Manual431
FC092326-03
Port The Port no. is allocated during DICOM configuration. 
Refer to your network specifications.
Verification Verify the connection to another DICOM application
Storage commitment Send a request to a PACS, asking it to permanently 
archive image(s)
MPPS Modality Perform Procedure Step: send information 
(typically to a HIS) that a scheduled exam has been 
started, performed or interrupted. DICOM settings Definition 

Page 446

Presets and System setup
432Vivid7/Vivid7 PRO Users Manual
FC092326-03
Additional outputs
The Additional outputs sheet deals with configuration of the 
PRINT and ALT keys on the control panel. Several outputs (e.g. 
Video Print, Laser print, DICOM storage...etc.) can be 
associated to the keys (i.e. hitting 
PRINT can result in printing a 
Color video print and storage to a DICOM media).
 Figure 12-16: The sublevel Additional outputs (example)
1. Select between PRINT and ALT keys.
2. Available output...

Page 447

Presets and System setup
Vivid7/Vivid7 PRO Users Manual433
FC092326-03
The image configuration parameters
The table below gives a list of the configuration parameters. 
To configure the Print or Alt. Print key
1. In Button field select Print or Alt. Print.
2. Select an output device in the available outputs field and 
press the Right arrow button to assign the service to the 
dataflow.
3. Press Properties.
The Properties window is displayed.
4. Adjust the device specific parameters as desired.
Some of...

Page 448

Presets and System setup
434Vivid7/Vivid7 PRO Users Manual
FC092326-03
To remove a device, select the device in the Selected devices 
field and press the Left arrow button. 

Page 449

Presets and System setup
Vivid7/Vivid7 PRO Users Manual435
FC092326-03
Tools
The Tools sublevel sheet deals with: 
•  formatting of removable media (MO disk, CD-R or ZIP disk).
•  verification of DICOM directory on removable media.
 Figure 12-17: The sublevel Tools
1. Select removable media to verify/format
2. Label a new removable MO disk (free text)
3. Verify DICOM directory on removable DICOM 
disk
4. Start formatting
5. Install a DICOM viewer6. Select the device for patient information 
exported as...

Page 450

Presets and System setup
436Vivid7/Vivid7 PRO Users Manual
FC092326-03
Formatting a removable media
1. Select the removable media from the Media pop-up menu.
2. Enter a name for the removable media in the Label field.
3. Check DICOM viewer is desired.
DICOM viewer enables the display of DICOM images from 
the removable media without the need of any other 
software.
4. Press Format.
5. Wait for the display of the Information window indicating 
that the formatting process is completed.
Do not eject the CD...