GE Logiq 7 User Manual
Here you can view all the pages of manual GE Logiq 7 User Manual. The GE manuals for Medical Equipment are available online for free. You can easily download all the documents as PDF.
Page 121
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 110 7.8.2 Private Templates LOGIQ 7 supports the following private templates for SOP Instances created by this product. xxvii. Private TID GEMS_US_0100 - GE Ultrasound M&A NL Relation with Parent Value Type Concept Name VM Req Type Condition Value Set Constraint 1 CONTAINER EV (43126, 99GEMS,”Ultrasound M&A Document”) 1 M > CONTAINS UIDREF EV (43140, 99GEMS,”Series Instance UID”) 1 U > CONTAINS...
Page 122
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 111 8. BASIC DIRECTORY INFORMATION OBJECT IMPLEMENTATION 8.1 INTRODUCTION This section specifies the use of the DICOM Basic Directory IOD to represent the information included in directories produced by this implementation. Corresponding attributes are conveyed using the module construct. The contents of this section are: 8.2 - IOD Implementation 8.3 - IOD Entity-Relationship Model 8.4- IOD Module Table 8.5 - IOD...
Page 123
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 112 ILLUSTRATION 8.3-1 BASIC DIRECTORY ENTITY RELATIONSHIP DIAGRAM Root Directory Entity Patient DR Includes 1 0 - n * Study DR * 1 - n Series DR * 1 - n Image DR 1 - n 1 1 1 8.4 IOD MODULE TABLE Within an entity of the Basic Directory IOD, attributes are grouped into related set of attributes. A set of related attributes is termed a module. A module facilitates the understanding of the semantics...
Page 124
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 113 The Directory Information Module is created when initializing the media. If it already exists, the existing information is not changed regarding patient, study, series or image data. An existing Directory Information Module may have been obtained from application entities using removable media. These instances are external to this conformance claim and the origin of the SOP instances is outside the scope of this...
Page 125
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 114 Attribute Name Tag Type Attribute Description >Offset of Referenced Lower-Level Directory Entity (0004,1420) 1C Is set >Directory Record Type (0004,1430) 1C The values support by FSC and FSU are PATIENT STUDY SERIES IMAGE >Private Record UID (0004,1432) 1C Not used >Referenced File ID (0004,1500) 1C Is set if Directory Record Type is IMAGE Contains the file path consisting of 5 elements: 1....
Page 126
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 115 Key Tag Type Attribute Description >Referenced SOP Class UID (0008,1150) 1C Is filled in by FSC and FSU as in chapter 4, 5, and 6. >Referenced SOP Instance UID (0008,1155) 1C Is filled in by FSC and FSU as in chapter 4, 5, and 6. Patients Birth Time (0010,0032) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Other Patient Ids (0010,1000) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Other...
Page 127
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 116 Key Tag Type Attribute Description >Referenced SOP Instance UID (0008,1155) 1C Is filled in by FSC and FSU as in chapter 4, 5, and 6. Admitting Diagnoses Description (0008,1080) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Patients Age (0010,1010) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Patients Size (0010,1020) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6.. Patients Weight...
Page 128
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 117 Key Tag Type Attribute Description Operator’s Name (0008,1070) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Referenced Performed Procedure Step Sequence (0008,1111) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. >Referenced SOP Class UID (0008,1150) 1C Is filled in by FSC and FSU as in chapter 4, 5, and 6.. >Referenced SOP Instance UID (0008,1155) 1C Is filled in by FSC and FSU as in chapter...
Page 129
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 118 Key Tag Type Attribute Description Manufacturer (0008,0070) 2 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Institution Name (0008,0080) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6.. Station Name (0008,1010) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6.. Institutional Department Name (0008,1040) 3 Is filled in by FSC and FSU as in chapter 4, 5, and 6. Manufacturers Model Name...
Page 130
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 119 8.5.3.4.1 Private Directory Record Definition Not used.8.5.3.5 Multi-Referenced File Directory Record Definition Not used. 8.6 PRIVATE DATA DICTIONARY If so configured, the product will send ultrasound raw data information in private data elements designated by the Private Creator element: Element Name Tag VR VM Description Private Creator 7FE1,00xx LO 1 GEMS_Ultrasound_MovieGroup_001 This means that all...