Home > Gateway > Notebook > Gateway E 4100 Service Manual

Gateway E 4100 Service Manual

Here you can view all the pages of manual Gateway E 4100 Service Manual. The Gateway manuals for Notebook are available online for free. You can easily download all the documents as PDF.

Page 141

Chapter 4131
Thermal Unit Failure
If the Thermal Unit fails, perform the following actions one at a time to correct the problem. Do not replace a 
non-defective FRUs:
External Mouse Failure
If an external Mouse fails, perform the following actions one at a time to correct the problem. 
1.Try an alternative mouse.
2.If the mouse uses a wireless connection, insert new batteries and confirm there is a good connection. See 
the mouse user manual.
3.If the mouse uses a USB connection, try an alternate USB...

Page 142

132Chapter 4
13.If the Issue is still not resolved, see “Online Support Information” on page 167.
Other Failures
If the CRT Switch, Dock, LAN Port, external MIC or Speakers, PCI Express Card, 5-in-1 Card Reader or 
Volume Wheel fail, perform the following general steps to correct the problem. Do not replace a non-defective 
FRUs:
1.Check Drive whether is OK.
2.Check Test Fixture is ok.
3.Swap M/B to Try.
Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that...

Page 143

Chapter 4133
Post Codes
These tables describe the POST codes and descriptions during the POST.
Sec:
NO_EVICTION_MODE_DEBUG   EQU        1 (CommonPlatform\sec\Ia32\SecCore.inc)
Memory:
DEBUG_BIOS   EQU   1 (Chipset\Alviso\MemoryInitAsm\IA32\IMEMORY.INC)
CodeDescription
0xC2 MTRR setup
0xC3 Enable cache
0xC4 Establish cache tags
0xC5 Enter NEM, Place the BSP in No Fill mode, set CR0.CD = 1, CR0.NW = 0.
0xCF Cache Init Finished
CodeDescription
0xA0 First memory check point
0x01 Enable MCHBAR
0x02 Check for...

Page 144

134Chapter 4
BDS & Specific action:0x28 Enable all clocks on populated rows
0x29 Perform JEDEC memory initialization for all memory rows
0x30 Perform steps required after memory init
0x31 Program DRAM throttling and throttling event registers
0x32 Setup DRAM control register for normal operation and enable
0x33 Enable RCOMP
0x34 Clear DRAM initialization bit in the SB
0x35 Initialization Sequence Completed, program graphic clocks
0xAF Disable access to the XMM registers
CodeDescription
0x00 Report the...

Page 145

Chapter 4135
Each PEIM entry point used in 80_PORT
Each Driver entry point used in 80_PORT0xF9 Runtime driver set virtual address map
CodeDescription
0x00
0x01 PEI_EVENT_LOG
0x02 PEI_OEM_SERVICE
0x03 PEI_SIO_INIT
0x04 PEI_MONO_STATUS_CODE
0x05 PEI_CPU_IO_PCI_CFG
0x06 PEI_CPU_IO
0x07 PEI_PCI_CFG
0x08 PEI_CPU_PEIM
0x09 PEI_PLATFORM_STAGE1
0x0A PEI_VARIABLE
0x0B PEI_SB_INIT
0x0C PEI_CAPSULE
0x0D PEI_PLATFORM_STAGE2
0x0E PEI_SB_SMBUS_ARP_DISABLED
0x0F PEI_HOST_TO_SYSTEM
0x10 PEI_MEMORY_INIT
0x11...

Page 146

136Chapter 4
0x37 HT_CPU / MP_CPU
0x38 LEGACY_METRONOME
0x39 FTWLITE
0x3A RUN_RIME
0x3B MONOTONIC_COUNTER
0x3C WATCH_DOG_TIMER
0x3D SECURITY_STUB
0x3E DXE_CPU_IO
0x3F CF9_RESET
0x40 PC_RTC
0x41 STATUS_CODE
0x42 VARIABLE
0x43 EMU_VARIABLE
0x44 DXE_CHIPSET_INIT
0x45 DXE_ALERT_FORMAT
0x46 PCI_HOST_BRIDGE
0x47 PCI_EXPRESS
0x48 DXE_SB_INIT
0x49 IDE_CONTROLLER
0x4A SATA_CONTROLLER
0x4B SB_SM_BUS
0x4C ISA_ACPI_DRIVER
0x4D ISA_BUS
0x4E ISA_SERIAL
0x4F IDE_BUS
0x50 PCI_BUS
0x51 BOOT_PRIORITY
0x52 FVB_SERVICE
0x53...

Page 147

Chapter 4137
0x62 CRISIS_RECOVERY
0x63 LEGACY_8259
0x64 LEGACY_REGION
0x65 LEGACY_INTERRUPT
0x66 BIOS_KEYBOARD
0x67 BIOS_VEDIO
0x68 MONITER_KEY
0x69 LEGACY_BIOS
0x6A LEGACY_BIOS_PLATFORM
0x6B PCI_PLATFORM
0x6C ISA_FLOOPY
0x6D PS2_MOUSE
0x6E USB_BOT
0x6F USB_CBI0
0x70 USB_CBI1
0x71 USB_KB
0x72 USB_MASS_STORAGE
0x73 BUS_PCI_UHCI
0x74 USB_MOUSE
0x75 USB_BUS
0x76 SETUP_UTILITY
0x77 FW_BLOCK_SERVICE
0x78 USB_LEGACY_PLATFORM
0x79 GRAPHICS_CONSOLE
0x7A TERMINAL
0x7B DATA_HUB_STD_ERR
0x7C FAT
0x7D PARTITION
0x7E...

Page 148

138Chapter 4
Each SmmDriver entry point used in 80_PORT0x8D CHINESE
0x8E TPM_S3_Resume
0x8F USB_EHCI
0x90 SNP_32_64
0x91 PXE_BC
0x92 PXE_DHCP4
0x93 EBC
0x94~0x9F RESERVED
0xA0 DXE_H2O_DEBUG_IO
0xA1 DXE_H2O_DEBUG_IO
0xA2 DXE_TPM_TCG
0xA3 DXE_TPM_PHYSICAL_PRESENCE
0xA4 DXE_OEM_SERVICE
0xA5 DXE_EVENT_LOG
0xA6 DXE_ SECURITY_HDD_PASSWORD_SERVICE
0xA7 DXE_LAN_ASF_INIT
0xA8 DXE_BUS_PCI_SERIAL
0xA9 DXE_LAN_IDER_CONTROLLER
0xAA DXE_LAN_AMT
0xAB DXE_ SECURITY_SYSTEM_PASSWORD_SERVICE
0xAC DXE_ SECURITY_...

Page 149

Chapter 4139
0xCE SMM_FW_BLOCK_SERVICE
0xCF SMM_VARIABLE
0xD0 SMM_IHISI
0xD1 SMM_INT15_MICROCODE
0xD2 SMM_PNP
0xD3 SMM_USB_LEGACY
0xD4 SMM_INT13_HDD
0xD5 SMM_INIT_PPM
0xD6 SMM_OHCI1394
0xD7 SMM_ SECURITY_HDD_PASSWORD_SERVICE
0xD8 SMM_OEM_SERVICE
0xD9 SMM_PPM
0xDA SMM_DIGITAL_THERMAL_SENSOR
CodeDescription 

Page 150

140Chapter 4 