Home > Fujitsu > Television > Fujitsu Myrica P42 2 User Manual

Fujitsu Myrica P42 2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Fujitsu Myrica P42 2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 86 Fujitsu manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  MYRICA P42-1A / P42-2 / P50-2 
    A26361-K1040-Z120-1-M119, edition 3  English - 29 
    TIME menu - time settings 
    ►  Press the MENU button to open the OSD menu. 
    ►  Mark the  Time menu item with the 
     /  buttons. 
    ►   Press the MENU button to activate the menu item. 
    The buttons available to you for setting t he options are shown in the menu footer. 
    MYRICA P42-1A  MYRICA P42-2 / P50-2 
       Time Set  With this button you set the current time. 
    Format: Hour:Minute 
    With MYRICA P42-1A: AM (before 12:00 noon);  PM (after 12:00 noon) 
    On Time  With this function you set the time at  which the device is to be automatically 
    switched on. 
    Format: Hour:Minute 
    To activate the function, set the selection to  On after setting the time.  
    To deactivate the function, set the selection to  Off after setting the time. 
    On Channel  With this function you set the program to be displayed after automatic 
    switch-on. 
    On Volume With this function you set the volume to be used after automatic switch-on. 
    Off Time With this function you set the time at  which the device is to be switched off 
    automatically. 
    Format: Hour:Minute 
    To activate the function, set the selection to  On after setting the time.  
    To deactivate the function, set the selection to  Off after setting the time. 
    Sleep  With this function you set the number  of minutes after which the device is 
    automatically switched off. 
    Possible values:  Off, 10 , 20 , 30 , 60 , 90 , 120 , 180  
     
     
    						
    							MYRICA P42-1A / P42-2 / P50-2 
    30 - English A26361-K1040-Z120-1-M119, edition 3 
    TV menu - programme settings 
    ►  Press the MENU button to open the OSD menu. 
    ►  Mark the  TV menu item with the 
     /  buttons. 
    ►   Press the MENU button to activate the menu item. 
    The buttons available to you for setting t he options are shown in the menu footer. 
      Auto Scan With this function you start the automatic programme search. 
    The automatic programme search must be carried out when you want to 
    use your plasma TV for the first time following installation. 
    The programmes will be entered in the programme list in the order in 
    which they are found. However, you can change the order of the 
    programmes later. 
    A detailed description is provided under Carrying out programme 
    search and Arranging programmes. 
    Manual Scan With this function you search for a new programme starting from the 
    frequency of the current channel. When the next programme has been 
    found, you can select whether or not the programme found is to be added 
    to the programme list. 
    To start the search manually, press the 
     button. 
    To add the programme found to the programme list, press the MENU 
    button. If you want to search for additional programmes, you must restart 
    the manual search. 
    To continue the search, press the 
     button. 
    Fine Tune  With this function you manually  set the frequency of an individual 
    channel. 
    The set values remain unchanged until an update is carried out. 
    Edit  With this function you set the order  of the programmes in the programme 
    list and the properties of the individual programme. 
    A detailed description is provided under  Adjusting programme settings. 
     
     
    						
    							  MYRICA P42-1A / P42-2 / P50-2 
    A26361-K1040-Z120-1-M119, edition 3  English - 31 
    Display modes 
    Main display mode 
    ►  Press the SOURCE button on the remote control or the INPUT SELECT button\
     on the 
    underside of the plasma TV to select the source fr om which the signal for the main display is to 
    come. 
    For the main display you can select one of the following signal sources: 
    ●  TV 
    ●  SCART1 
    ●  SCART2 
    ●   S-VIDEO or CVBS (AV) 
    ●   Component 1 (YPbPr) 
    ●   Component 2 (YPbPr) 
    ●  VGA (PC) 
    ●  DVI 
    By pressing the INFO button you display the designat ion of the currently selected signal sources in 
    the upper left corner of the screen. 
     
     
    						
    							MYRICA P42-1A / P42-2 / P50-2 
    32 - English A26361-K1040-Z120-1-M119, edition 3 
    PIP mode (Picture in Picture) 
    The plasma TV can also display a sub-video signal in addition to the main video signal. The sub-
    video signal is shown as a PIP display in a window on the main display. 
    The following buttons of the remote control are available for setting the PIP mode. 
    ►  Press the ON/OFF button to activate the PIP mode. 
    ►   Press the SOURCE button to select the source from which the signal for the PIP display is to 
    come. 
    ►   Press the SIZE button to set the size of the PIP display. 
    ►   Press the POSITION button to set the position of the PIP display. 
    ►   Press the SWAP button to exchange the size and position of the main display with those of the 
    PIP display. 
    ►   Press the POP button to display the main display and the PIP display in the same size next to 
    each other. 
    ►   If a TV signal is displayed in the PIP display, you change to the next programme in the 
    programme list with the PR+ button, and to the previous programme in the programme list with 
    the PR- button. 
    Depending on which source the signal for the main display comes from, you can use certain sources 
    for the signal of the PIP display. 
    The following combination options are available to you: 
     Signal 
    sources Main display 
      TV  AV  SV  SCART 1 SCART 2 VGA  DVI  YPbPr 
    TV         
    AV   - -      
    SV  - -      
    SCART 
    1     -     
    SCART 
    2      -    
    VGA      - - - 
    DVI      - - - 
     
    PIP display 
    YPbPr       - - -  
     
    						
    							  MYRICA P42-1A / P42-2 / P50-2 
    A26361-K1040-Z120-1-M119, edition 3  English - 33 
    Technical data 
     MYRICA P42-1A MYRICA P42-2  MYRICA P50-2  
    Screen:      
    Size (diagonal)  42 (107 cm)  42 (107 cm)  50 (126.9 cm) 
    Visible picture (HxV):  934 mm x 532.2 mm  934 mm x 532.2 mm  1,107 mm x 622 mm 
    Number of pixels 
    (HxV):  852 x 480  1024 x 768  1366 x 768, WXGA 
    Pixel spacing:  0.912 mm x 0.693 mm  0.912 mm x 0.693 mm  0.81 mm x 0.81 mm 
    Brightness:  typical: 1000 cd/m²  typical: 900 cd/m²  typical: 1000 cd/m² 
    Contrast:  typical: 3000:1  typical: 2500:1  typical: 3000:1 
    Viewing angle:  typical > 160° 
    Number of colours:  16.7 mio 
    Picture format:  16:9 
    Horizontal frequency:  31.15 - 69 kHz  31.15 - 82 kHz  31.15 - 82 kHz 
    Refresh rate:  56 - 85 Hz  56 - 75 Hz (digital) 
    56 - 90 Hz (analogue) 56 - 75 Hz (digital) 
    56 - 90 Hz (analogue) 
    Maximal resolution:  1024 x 768/ 75 Hz 
    (analogue/digital) 1280 x 1024 / 60 Hz 
    (analogue/digital)  1280 x 1024 / 60 Hz 
    (analogue/digital) 
    Synchronisation:
      
    Separate:  H / V TTL, P or N 
    Composite:  H / V TTL, P or N 
    Green synchronisation:  Composite 0.3 Vp-p, negative 
    Video 0.7 Vp-p, positive 
    Video signal:  0,7 Vp-p / 75 Ohm 
    Colour system:  PAL / SECAM 
    Sound system:  BG, DK, I, L 
    Video format:  CVBS, S-VHS 
    DTV: 
    YPbPr 
    YUV 
    Video / Mode   
    Composite  Separate 
    0.7 Vp-p / 720 p @ 1080 i 
    SCART 1: 
    Video input/output 
    Audio input/output   
     
    1.0 Vp-p @  75 Ohm 
     
    0.5 Vms 
     
    						
    							MYRICA P42-1A / P42-2 / P50-2 
    34 - English A26361-K1040-Z120-1-M119, edition 3 
     
     MYRICA P42-1A MYRICA P42-2  MYRICA P50-2  
    DVI:  TMDS ( DVI-D) 
    Power supply (AC):  100 - 240 V (50/60 Hz) 
    2 A / 240 V 
    4.6 A / 100 V 100 - 240 V (50/60 Hz) 
    2 A / 240 V 
    4.6 A / 100 V  100 - 240 V (50/60 Hz) 
    2 A / 240 V 
    5 A / 100 V 
    Power consumption:  typical: 300 W 
    Standby < 5 W typical: 385 W 
    Standby < 5 W  typical: 500 W 
    Standby < 5 W 
    Dimensions: 
       
    Width x Depth x Height:  1037 x 110 x 635 mm 
    (without foot) 
    1037 x 240 x 703 mm 
    (with foot) 1037 x 110 x 635 mm 
    (without foot) 
    1037 x 240 x 703 mm 
    (with foot)  1208 x 110 x 723 mm 
    (without foot) 
    1208 x 360 x 775 mm 
    (with foot) 
    Weight:  approx. 41 kg 
    packed approx. 46 kg approx. 41 kg 
    packed approx. 46 kg  approx. 54 kg 
    packed approx. 60 kg 
    Audio:
      
    Audio input: 
    DVI / PC, Video 1, 
    S-Video, 
    Component1/2, 
    (SCART 1, SCART 2)   
    RCA connection (L, R) 0.5 Vms 
    Audio output:  0.5 Vms at 1 kHz 
    Loudspeaker output:  approx. 2 x 8 W (8 Ohm) 
    RS-232:  For Service only 
    Standard certificate:   
    Security: TÜV-GS ,CE 
    EMC:  TV mode: EN55020 class B, EN 55013, EN 61000-3-2/-3 (see CE) 
    PC mode: EN55022 class B, EN 55024, EN 61000-3-2/-3 (see CE) 
    Environment:  Condensation must be avoided. 
    Temperature:  Operating: +15 ° to +35 ° C 
    Storage: -15 ° to + 60 ° C 
    Change: 1.5 ° C/minute maximum 
    Humidity:  Operation: 20 - 85 % without condensation  Storage: 20 - 85 % without condensation 
    Pressure:  Operation : 800 - 1,114 hPa (height: 0 - 2000 m) Storage : 600 - 1,114 hPa (height: 0 - 4500 m) 
    Accessories:  Manual, remote control, battery 
    Power supply cable: 1.8 m 
    Foot with mounting screws 
     
    						
    							  MYRICA P42-1A / P42-2 / P50-2 
    A26361-K1040-Z120-1-M119, edition 3  English - 35 
    VESA-DDC-compatible VGA interface 
    Your plasma TV is equipped with a VESA-DDC-compatible VGA interface and a DVI-D interface. 
    VESA-DDC (Video Electronics Standard Association,  Display Data Channel) is used as the 
    communications interface between the plasma TV  and the computer. If your computer is equipped 
    with a VESA-DDC-compatible VGA interface, it can  automatically read the data for ensuring optimum 
    operation from your plasma TV and select the appropriate settings. 
    Preset operating modes (PC) 
    The following are the most frequently used of the preset operating modes: 
    Resolution Refresh rate 
    640 x 350 
    640 x 480 
    800 x 600 
    1024 x 768 
    1280 x 720 *) 
    1280 x 768 *) 
    1280 x 1024 *)  70 Hz 
    60 Hz, 72 Hz, 75 Hz 
    56 Hz, 60 Hz, 72 Hz 
    60 Hz, 70 Hz, 75 Hz  60 Hz, 75 Hz 
    60 Hz, 75 Hz 60 Hz 
    *) not with MYRICA P42-1A 
    Power consumption 
    To save energy when the device is temporarily not  in use, the plasma TV can be switched into the 
    standby mode with the remote control (POWER button) or the STANDBY button. 
      Switched on  Standby mode 
    Power indicator  lights green  lights red 
    Function  Device operates normally  the screen is dark 
    Power consumption  normal < 300 W (P42-1A)  normal < 385 W (P42-2) 
    normal < 500 W (P50-2)  reduced to < 5 W (P42-1A) 
    reduced to < 5 W (P42-2) 
    reduced to < 5 W (P50-2) 
     
    i  If the device is switched into the standby m
    ode, a power consumption of up to 5 W is 
    maintained to enable operation with the remote control.  
    To completely switch off the power consumption, switch off the device with the ON/OFF 
    switch (see Switching plasma TV on/off).. 
     
     
    						
    							MYRICA P42-1A / P42-2 / P50-2 
    36 - English A26361-K1040-Z120-1-M119, edition 3 
    PC Analogue (D-SUB) 
    1
    5
    6
    10
    11
    15
     
    Pin Meaning  Pin Meaning 
    1  Video input red    9  +5 V (DDC) 
    2  Video input green    10  Sync. earth 
    3  Video input blue    11  Earth 
    4 Earth  12 DDC-Data 
    5 Earth  13 H. sync 
    6  Red video earth    14  V. sync 
    7  Green video earth    15  DDC Clock 
    8  Blue video earth        
    PC Digital (DVI-D) 
    1 9
    17
     
    Pin Meaning   Pin Meaning   Pin  Meaning 
    1  TMDS Data2-    9  TMDS Data1-    17  TMDS Data0- 
    2  TMDS Data2+    10  TMDS Data1+    18  TMDS Data0+ 
    3  TMDS Data 2/4  Shield    11  TMDS Data 1/3 
    Shield    19  TMDS Data 0/5 Shield 
    4  not connected    12  not connected    20  not connected 
    5  not connected    13  not connected    21  not connected 
    6  DDC Clock    14  +5V Power    22  TMDS Clock Shield 
    7  DDC Data    15  Earth    23  TMDS Clock- 
    8 Analogue Vertical 
    Sync    16  Hot Plug Detect    24  TMDS Clock+ 
     
     
    						
    							  MYRICA P42-1A / P42-2 / P50-2 
    A26361-K1040-Z120-1-M119, edition 3  English - 37 
    SCART (Half/Full) 
      
    Pin Meaning    Pin Meaning   Pin Meaning 
    1  Sound (R) output    8  Changeover voltage    15  Red *) 
    2  Sound (R) input    9  Green earth *)    16  Blanking *) 
    3  Sound (L) output    10  Not assigned    17  Video output earth 
    4  Sound signal earth    11  Green *)    18  Video input earth 
    5  Blue earth *)    12  Not assigned    19  Video output **) 
    6  Sound (L) input    13  Red earth *)    20  Video input 
    7  Blue *)    12  Blanking earth    21  Shield earth  *) Not used with SCART (Half) 
    **) TV-Out for SCART (Half); current picture signal for SCART (Full)\
     
    S-Video 
    Pin  Meaning  
    1 GND 
    2 GND 
    3 Luminance (Y) 
     
    4 Chrominance (C) 
     
     
    						
    							MYRICA P42-1A / P42-2 / P50-2 
    38 - English A26361-K1040-Z120-1-M119, edition 3 
    Colour and transmission system by country 
    Country TV Colour Stereo Subtitles 
    Albania B/G PAL   
    Austria B/G PAL FM-FM Teletext 
    Azores B PAL   
    Bahrain B PAL   
    Belgium B/G PAL Nicam Teletext 
    Bulgaria D SECAM   
    Canary Islands  B  PAL     
    Croatia B/H PAL   
    Cyprus B PAL   
    Czech Republic  D/K  SECAM / PAL     
    Denmark B PAL Nicam Teletext 
    Egypt B SECAM   
    Faroe Islands (DK)  B  PAL     
    Finland B/G PAL Nicam Teletext 
    France E/L SECAM  Teletext 
    Germany B/G PAL FM-FM Teletext 
    Gibraltar B PAL   
    Greece B/G PAL   
    Hungary  B/G & D/K  PAL  Nicam (Budapest only)   
    Iceland B PAL   
    Iran H SECAM   
    Ireland I PAL Nicam Teletext 
    Israel B/G PAL Nicam Teletext 
    Italy B/G PAL FM-FM Teletext 
    Jordan B PAL   
    Kenia B PAL   
    Luxemburg B/G PAL Nicam Teletext 
    Madeira B PAL   
    Malta B/G PAL   
    Marocco B SECAM   
    Monaco  L/G  SECAM / PAL     
    Netherlands B/G PAL FM-FM Teletext 
     
    						
    All Fujitsu manuals Comments (0)

    Related Manuals for Fujitsu Myrica P42 2 User Manual