MYRICA P42-1A / P42-2 / P50-2 A26361-K1040-Z120-1-M119, edition 3 English - 29 TIME menu - time settings ► Press the MENU button to open the OSD menu. ► Mark the Time menu item with the / buttons. ► Press the MENU button to activate the menu item. The buttons available to you for setting t he options are shown in the menu footer. MYRICA P42-1A MYRICA P42-2 / P50-2 Time Set With this button you set the current time. Format: Hour:Minute With MYRICA P42-1A: AM (before 12:00 noon); PM (after 12:00 noon) On Time With this function you set the time at which the device is to be automatically switched on. Format: Hour:Minute To activate the function, set the selection to On after setting the time. To deactivate the function, set the selection to Off after setting the time. On Channel With this function you set the program to be displayed after automatic switch-on. On Volume With this function you set the volume to be used after automatic switch-on. Off Time With this function you set the time at which the device is to be switched off automatically. Format: Hour:Minute To activate the function, set the selection to On after setting the time. To deactivate the function, set the selection to Off after setting the time. Sleep With this function you set the number of minutes after which the device is automatically switched off. Possible values: Off, 10 , 20 , 30 , 60 , 90 , 120 , 180
MYRICA P42-1A / P42-2 / P50-2 30 - English A26361-K1040-Z120-1-M119, edition 3 TV menu - programme settings ► Press the MENU button to open the OSD menu. ► Mark the TV menu item with the / buttons. ► Press the MENU button to activate the menu item. The buttons available to you for setting t he options are shown in the menu footer. Auto Scan With this function you start the automatic programme search. The automatic programme search must be carried out when you want to use your plasma TV for the first time following installation. The programmes will be entered in the programme list in the order in which they are found. However, you can change the order of the programmes later. A detailed description is provided under Carrying out programme search and Arranging programmes. Manual Scan With this function you search for a new programme starting from the frequency of the current channel. When the next programme has been found, you can select whether or not the programme found is to be added to the programme list. To start the search manually, press the button. To add the programme found to the programme list, press the MENU button. If you want to search for additional programmes, you must restart the manual search. To continue the search, press the button. Fine Tune With this function you manually set the frequency of an individual channel. The set values remain unchanged until an update is carried out. Edit With this function you set the order of the programmes in the programme list and the properties of the individual programme. A detailed description is provided under Adjusting programme settings.
MYRICA P42-1A / P42-2 / P50-2 A26361-K1040-Z120-1-M119, edition 3 English - 31 Display modes Main display mode ► Press the SOURCE button on the remote control or the INPUT SELECT button\ on the underside of the plasma TV to select the source fr om which the signal for the main display is to come. For the main display you can select one of the following signal sources: ● TV ● SCART1 ● SCART2 ● S-VIDEO or CVBS (AV) ● Component 1 (YPbPr) ● Component 2 (YPbPr) ● VGA (PC) ● DVI By pressing the INFO button you display the designat ion of the currently selected signal sources in the upper left corner of the screen.
MYRICA P42-1A / P42-2 / P50-2 32 - English A26361-K1040-Z120-1-M119, edition 3 PIP mode (Picture in Picture) The plasma TV can also display a sub-video signal in addition to the main video signal. The sub- video signal is shown as a PIP display in a window on the main display. The following buttons of the remote control are available for setting the PIP mode. ► Press the ON/OFF button to activate the PIP mode. ► Press the SOURCE button to select the source from which the signal for the PIP display is to come. ► Press the SIZE button to set the size of the PIP display. ► Press the POSITION button to set the position of the PIP display. ► Press the SWAP button to exchange the size and position of the main display with those of the PIP display. ► Press the POP button to display the main display and the PIP display in the same size next to each other. ► If a TV signal is displayed in the PIP display, you change to the next programme in the programme list with the PR+ button, and to the previous programme in the programme list with the PR- button. Depending on which source the signal for the main display comes from, you can use certain sources for the signal of the PIP display. The following combination options are available to you: Signal sources Main display TV AV SV SCART 1 SCART 2 VGA DVI YPbPr TV AV - - SV - - SCART 1 - SCART 2 - VGA - - - DVI - - - PIP display YPbPr - - -
MYRICA P42-1A / P42-2 / P50-2 A26361-K1040-Z120-1-M119, edition 3 English - 33 Technical data MYRICA P42-1A MYRICA P42-2 MYRICA P50-2 Screen: Size (diagonal) 42 (107 cm) 42 (107 cm) 50 (126.9 cm) Visible picture (HxV): 934 mm x 532.2 mm 934 mm x 532.2 mm 1,107 mm x 622 mm Number of pixels (HxV): 852 x 480 1024 x 768 1366 x 768, WXGA Pixel spacing: 0.912 mm x 0.693 mm 0.912 mm x 0.693 mm 0.81 mm x 0.81 mm Brightness: typical: 1000 cd/m² typical: 900 cd/m² typical: 1000 cd/m² Contrast: typical: 3000:1 typical: 2500:1 typical: 3000:1 Viewing angle: typical > 160° Number of colours: 16.7 mio Picture format: 16:9 Horizontal frequency: 31.15 - 69 kHz 31.15 - 82 kHz 31.15 - 82 kHz Refresh rate: 56 - 85 Hz 56 - 75 Hz (digital) 56 - 90 Hz (analogue) 56 - 75 Hz (digital) 56 - 90 Hz (analogue) Maximal resolution: 1024 x 768/ 75 Hz (analogue/digital) 1280 x 1024 / 60 Hz (analogue/digital) 1280 x 1024 / 60 Hz (analogue/digital) Synchronisation: Separate: H / V TTL, P or N Composite: H / V TTL, P or N Green synchronisation: Composite 0.3 Vp-p, negative Video 0.7 Vp-p, positive Video signal: 0,7 Vp-p / 75 Ohm Colour system: PAL / SECAM Sound system: BG, DK, I, L Video format: CVBS, S-VHS DTV: YPbPr YUV Video / Mode Composite Separate 0.7 Vp-p / 720 p @ 1080 i SCART 1: Video input/output Audio input/output 1.0 Vp-p @ 75 Ohm 0.5 Vms
MYRICA P42-1A / P42-2 / P50-2 34 - English A26361-K1040-Z120-1-M119, edition 3 MYRICA P42-1A MYRICA P42-2 MYRICA P50-2 DVI: TMDS ( DVI-D) Power supply (AC): 100 - 240 V (50/60 Hz) 2 A / 240 V 4.6 A / 100 V 100 - 240 V (50/60 Hz) 2 A / 240 V 4.6 A / 100 V 100 - 240 V (50/60 Hz) 2 A / 240 V 5 A / 100 V Power consumption: typical: 300 W Standby < 5 W typical: 385 W Standby < 5 W typical: 500 W Standby < 5 W Dimensions: Width x Depth x Height: 1037 x 110 x 635 mm (without foot) 1037 x 240 x 703 mm (with foot) 1037 x 110 x 635 mm (without foot) 1037 x 240 x 703 mm (with foot) 1208 x 110 x 723 mm (without foot) 1208 x 360 x 775 mm (with foot) Weight: approx. 41 kg packed approx. 46 kg approx. 41 kg packed approx. 46 kg approx. 54 kg packed approx. 60 kg Audio: Audio input: DVI / PC, Video 1, S-Video, Component1/2, (SCART 1, SCART 2) RCA connection (L, R) 0.5 Vms Audio output: 0.5 Vms at 1 kHz Loudspeaker output: approx. 2 x 8 W (8 Ohm) RS-232: For Service only Standard certificate: Security: TÜV-GS ,CE EMC: TV mode: EN55020 class B, EN 55013, EN 61000-3-2/-3 (see CE) PC mode: EN55022 class B, EN 55024, EN 61000-3-2/-3 (see CE) Environment: Condensation must be avoided. Temperature: Operating: +15 ° to +35 ° C Storage: -15 ° to + 60 ° C Change: 1.5 ° C/minute maximum Humidity: Operation: 20 - 85 % without condensation Storage: 20 - 85 % without condensation Pressure: Operation : 800 - 1,114 hPa (height: 0 - 2000 m) Storage : 600 - 1,114 hPa (height: 0 - 4500 m) Accessories: Manual, remote control, battery Power supply cable: 1.8 m Foot with mounting screws
MYRICA P42-1A / P42-2 / P50-2 A26361-K1040-Z120-1-M119, edition 3 English - 35 VESA-DDC-compatible VGA interface Your plasma TV is equipped with a VESA-DDC-compatible VGA interface and a DVI-D interface. VESA-DDC (Video Electronics Standard Association, Display Data Channel) is used as the communications interface between the plasma TV and the computer. If your computer is equipped with a VESA-DDC-compatible VGA interface, it can automatically read the data for ensuring optimum operation from your plasma TV and select the appropriate settings. Preset operating modes (PC) The following are the most frequently used of the preset operating modes: Resolution Refresh rate 640 x 350 640 x 480 800 x 600 1024 x 768 1280 x 720 *) 1280 x 768 *) 1280 x 1024 *) 70 Hz 60 Hz, 72 Hz, 75 Hz 56 Hz, 60 Hz, 72 Hz 60 Hz, 70 Hz, 75 Hz 60 Hz, 75 Hz 60 Hz, 75 Hz 60 Hz *) not with MYRICA P42-1A Power consumption To save energy when the device is temporarily not in use, the plasma TV can be switched into the standby mode with the remote control (POWER button) or the STANDBY button. Switched on Standby mode Power indicator lights green lights red Function Device operates normally the screen is dark Power consumption normal < 300 W (P42-1A) normal < 385 W (P42-2) normal < 500 W (P50-2) reduced to < 5 W (P42-1A) reduced to < 5 W (P42-2) reduced to < 5 W (P50-2) i If the device is switched into the standby m ode, a power consumption of up to 5 W is maintained to enable operation with the remote control. To completely switch off the power consumption, switch off the device with the ON/OFF switch (see Switching plasma TV on/off)..
MYRICA P42-1A / P42-2 / P50-2 36 - English A26361-K1040-Z120-1-M119, edition 3 PC Analogue (D-SUB) 1 5 6 10 11 15 Pin Meaning Pin Meaning 1 Video input red 9 +5 V (DDC) 2 Video input green 10 Sync. earth 3 Video input blue 11 Earth 4 Earth 12 DDC-Data 5 Earth 13 H. sync 6 Red video earth 14 V. sync 7 Green video earth 15 DDC Clock 8 Blue video earth PC Digital (DVI-D) 1 9 17 Pin Meaning Pin Meaning Pin Meaning 1 TMDS Data2- 9 TMDS Data1- 17 TMDS Data0- 2 TMDS Data2+ 10 TMDS Data1+ 18 TMDS Data0+ 3 TMDS Data 2/4 Shield 11 TMDS Data 1/3 Shield 19 TMDS Data 0/5 Shield 4 not connected 12 not connected 20 not connected 5 not connected 13 not connected 21 not connected 6 DDC Clock 14 +5V Power 22 TMDS Clock Shield 7 DDC Data 15 Earth 23 TMDS Clock- 8 Analogue Vertical Sync 16 Hot Plug Detect 24 TMDS Clock+
MYRICA P42-1A / P42-2 / P50-2 A26361-K1040-Z120-1-M119, edition 3 English - 37 SCART (Half/Full) Pin Meaning Pin Meaning Pin Meaning 1 Sound (R) output 8 Changeover voltage 15 Red *) 2 Sound (R) input 9 Green earth *) 16 Blanking *) 3 Sound (L) output 10 Not assigned 17 Video output earth 4 Sound signal earth 11 Green *) 18 Video input earth 5 Blue earth *) 12 Not assigned 19 Video output **) 6 Sound (L) input 13 Red earth *) 20 Video input 7 Blue *) 12 Blanking earth 21 Shield earth *) Not used with SCART (Half) **) TV-Out for SCART (Half); current picture signal for SCART (Full)\ S-Video Pin Meaning 1 GND 2 GND 3 Luminance (Y) 4 Chrominance (C)
MYRICA P42-1A / P42-2 / P50-2 38 - English A26361-K1040-Z120-1-M119, edition 3 Colour and transmission system by country Country TV Colour Stereo Subtitles Albania B/G PAL Austria B/G PAL FM-FM Teletext Azores B PAL Bahrain B PAL Belgium B/G PAL Nicam Teletext Bulgaria D SECAM Canary Islands B PAL Croatia B/H PAL Cyprus B PAL Czech Republic D/K SECAM / PAL Denmark B PAL Nicam Teletext Egypt B SECAM Faroe Islands (DK) B PAL Finland B/G PAL Nicam Teletext France E/L SECAM Teletext Germany B/G PAL FM-FM Teletext Gibraltar B PAL Greece B/G PAL Hungary B/G & D/K PAL Nicam (Budapest only) Iceland B PAL Iran H SECAM Ireland I PAL Nicam Teletext Israel B/G PAL Nicam Teletext Italy B/G PAL FM-FM Teletext Jordan B PAL Kenia B PAL Luxemburg B/G PAL Nicam Teletext Madeira B PAL Malta B/G PAL Marocco B SECAM Monaco L/G SECAM / PAL Netherlands B/G PAL FM-FM Teletext