WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Housings 71 Confidential 4.2.6 Decoration Plate Left/Right 1.Remove the Rear Housing. (p.68) 2.Remove the Front Decoration Plate Left/Right. (p.68) 3. Release the three hooks on the front of the Decoration Plate Right and lift the plate a little to release the tab and the four guide pins on the upper side, then remove the Decoration Plate Right. 4. In the same way, remove the Decoration Plate Left. Figure 4-13. Removing the Decoration Plate Left/Right Decoration Plate Right Hook (x3) Tab Guide pin (x4) When installing the Decoration Plate L/R, first align the hooks of the Decoration Plate L/R (two each) with the ribs of the Lower Housing (two each on the left/right), and then align the tab inside the Decotrative Plate L/R (one each) with the positioning hole on the Upper Housing (one each on the left/right). Figure 4-14. Reinstalling the Decoration Plate Left/Right Tab Hooks and Ribs Positioning hole
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Housings 72 Confidential 4.2.7 Upper Housing / Printer Cover 1.Remove the Decoration Plate Left/Right. (p.71) 2.Remove the Panel Unit. (p.69) 3. Remove the seven C.B.P. M3 x 10 screws that secure the Upper Housing. 4. Remove the Upper Housing while pulling out the Panel FFC through the cutout of the Upper Housing. Figure 4-15. Remove the Upper Housing 1) C.B.P. M3x10 (6±1 kgf.cm) 6 1) C.B.P. M3x10 (6±1 kgf.cm) 7 1) C.B.P. M3x10 (6±1 kgf.cm) 5 2 1) C.B.P. M3x10 (6±1 kgf.cm) 1 3 1) C.B.P. M3x10 (6±1 kgf.cm) 4 Upper Housing Route the Panel FFC correctly as shown in Figure 4-12. Install the Upper Housing so that the Grounding Plate properly protrudes through the cutout of the Upper Housing. Figure 4-16. Routing the Panel FFC Tighten the screws in the order shown in Figure 4-15. After replacing the following parts, be sure to apply G-74 grease to the area specified for each part. Upper Housing: See Figure 6-14 on page 158. Upper Housing Grounding Plate
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Housings 73 Confidential REMOVING THE PRINTER COVER 1.Remove the Upper Housing / Printer Cover. (p.72) 2. Remove the two C.B.P. M3 x 8 screws that secure Printer Cover Holder Left/ Right. Figure 4-17. Removing the Printer Cover Holder Left/Right3. Remove the Printer Cover Holder Right following the steps below. 3-1. With the Printer Cover open, put the Upper Housing with the rear side up. 3-2. Slide the Printer Cover Holder Right in the direction of the arrow while lifting it, and remove the Printer Cover Holder Right from the Upper Housing. Figure 4-18. Removing the Printer Cover 4. While holding the Printer Cover, remove the Printer Cover Holder Left in the same manner as Step 3-2, and remove the Printer Cover from the Upper Housing. Insert the tabs (two each on the left/right) shown in Figure 4-17 into the holes on the Upper Housing. TabsTabs 4) C.B.P. M3x8 (6±1 kgf.cm)4) C.B.P. M3x8 (6±1 kgf.cm) Upper Housing Printer Cover Holder RightPrinter Cover Holder Left Be careful not to damage the surface in step 3 and later. When performing the following steps, be careful not to damage the tabs of the Printer Cover Holder Right. Printer Cover Upper Housing TabPrinter Cover Holder Right
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Housings 74 Confidential 4.2.8 Upper Housing Support Assy 1.Remove the Upper Housing / Printer Cover. (p.72) 2. Remove the two C.B.S. M3 x 6 screws and two C.B.P. M3 x 10 screws that secure the Upper Housing Support Assy, and remove the Upper Housing Support Assy. Figure 4-19. Removing the Upper Housing Support Assy After replacing the following parts, be sure to apply G-26 grease to the area specified for each part. Printer Cover Holder Left: Chapter 6 See Figure 6-13 (p.158). Printer Cover Holder Right: Chapter 6 See Figure 6-13 (p.158). Secure the Grounding Plate with one of the C.B.S. M3 x 6 screws together with the Upper Housing as shown below. 1) C.B.P. M3x10 (6±1 kgf.cm)1) C.B.P. M3x10 (6±1 kgf.cm) Upper Housing Support Assy 2) C.B.S. M3x6 (6±1 kgf.cm)
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Boards 75 Confidential 4.3 Removing the Boards 4.3.1 Board Assy (Main Board/Power Supply Board) 1.Remove the Upper Housing / Printer Cover. (p.72) 2. Remove the seven screws (four C.B.S. M3 x 6, two C.B.S. (P2) M3 x 8, and one C.B.S. M3 x 8) that secure the Board Assy. Figure 4-20. Removing the Board Assy (1)3. Disconnect all the cables and FFCs connected on the Main Board from the near side one by one. Figure 4-21. Connector Layout of the Main Board (130 Digit Side) Tighten the screws in the order shown in Figure 4-20. Board Assy 2 56 15) C.B.S. (P2) M3x8 (6±1 kgf.cm) 134 7 5) C.B.S. M3x8 (6±1 kgf.cm) 2) C.B.S. M3x6 (6±1 kgf.cm) No.ConnectorNo.Connector CN4 Panel Bard, Cover Open Sensor CN22 CSIC CN5Relay FFC (for sensor)CN115CR Motor CN9 CR Encoder Sensor, PW Sensor CN116 PF Motor CN11CR Relay BoardCN117Pump Motor CN12 CR Relay Board CN118 APG Motor CN13CR Relay BoardCN119ASF Motor CN116 CN5 CN4 CN12 CN118CN117 CN13 CN19 CN11 CN15 CN22 CN9
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Boards 76 Confidential 4. Pull out the Board Assy from the Printer. Figure 4-22. Removing the Board Assy (2)REMOVING THE MAIN BOARD 1.Remove the Board Assy (Main Board/Power Supply Board). (p.75) 2. Disconnect the Power Board cable from connector CN60 on the Main Board. 3. Remove the four C.B.S. M3 x 6 screws and one C.P. M3 x 4 screw that secure the Main Board and remove the Main Board from the Board Assy. Figure 4-25. Removing the Main Board Confirm that the FFCs do not cross each other first, then connect the FFCs and the cables to the Main Board while paying attention to the edge of the Shield Plate. Take care not to place the Board Assy onto the three Ground Plates. Figure 4-23. Reinstalling the Board Assy Board Assy Grounding Plates When disconnecting the Power Board cable, be sure to unlock CN60 on the Main Board. Figure 4-24. Handling the Power Board cable (CN60) LockUnlock 1 23 4 CN60 Main Board 2) C.B.S. M3x6 (6±1 kgf.cm) 14) C.P. M3x4 (4±1 kgf.cm)5
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Removing the Boards 77 Confidential REMOVING THE POWER BOARD 1.Remove the Board Assy (Main Board/Power Supply Board). (p.75) 2. Disconnect the Power Board cable from connector CN60 on the Main Board. (p.76) 3. Remove the four C.B.S. M3 x 6 screws that secure the Power Board and remove the Power Board from the Board Assy. Figure 4-27. Removing the Power Board When disconnecting the Power Board cable, be sure to unlock CN60 on the Main Board. Figure 4-26. Handling the Power Board cable (CN60) Tighten the screws in the order shown in Figure 4-25 and Figure 4-27. LockUnlock Power Board 2) C.B.S. M3x6 (6±1 kgf.cm) 1 23 4 After replacing or removing the Main Board and the Power Board, always make the required adjustments referring to the following. “Chapter 5 Adjustment (p.128)”
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Disassembling the Printer Mechanism 78 Confidential 4.4 Disassembling the Printer Mechanism 4.4.1 APG Assy 1.Remove the Upper Housing / Printer Cover. (p.72) 2. Disconnect the APG Motor connector cable from connector CN118 (red) on the Main Board. 3. Peel off the acetate tape, and remove the APG Motor cable from the ASF Assy. 4. Disconnect the cables from the two APG Sensor connectors. Figure 4-28. Disconnecting the Cables5. Remove the three C.B.S. M3 x 6 screws that secure the APG Assy, and remove the APG Assy from the Main Frame. Figure 4-29. Removing the APG Assy Referring to Figure 4-28, correctly route the APG connector cable. APG Assy APG Motor APG Sensor connectors CN118 Hook the APG Motor cable on the two tabs of the ASF Assy. Acetate tape 3 1 2 2) C.B.S. M3x6 (8±1 kgf.cm)
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Disassembling the Printer Mechanism 79 Confidential 4.4.2 CR Scale 1.Remove the Upper Housing / Printer Cover. (p.72) 2. Release the Carriage Lock, and move the Carriage Unit to the center. (Refer to 4.1.5 Locking/Releasing the Carriage (p.65).) 3. Pull the right end of the CR Scale in the direction of the arrow, and remove the CR Scale from the tab on the Right CR Shaft Mounting Plate. 4. Pull out the right end of the CR Scale towards the left direction from the rear of the Carriage Unit. Figure 4-31. Pulling out the CR Scale Align the phase of the APG Assy in the following procedure. 1.Align the delta marks of Spur Gear 16 and Combination Gear 22, 28.8, 32.4. 2. At the position where the tab can be identified through the notch of the PG Frame, align the delta marks of Spur Gear 16 and PG Cam (Left). Figure 4-30. Phase Aligning Tighten the screws in the order shown in Figure 4-29. Delta Marks Spur Gear 16 Combination Gear, 22, 28.8, 32.4 Delta Marks Tab Spur Gear 16 PG Cam (Left) When performing the following procedure, take care to prevent both ends of the CR Scale from being broken. Step 3Step 4 Carriage UnitRight CR Shaft Mounting Plate CR Scale Hook
WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision C Disassembly And Assembly Disassembling the Printer Mechanism 80 Confidential 5. Remove the coil section of Torsion Spring 24.7 from the tab on the Left CR Shaft Mounting Plate with tweezers. Figure 4-32. Removing the Torsion Spring 24.7 (1) 6. Remove Torsion Spring 24.7 from the CR Scale by the following procedure: 6-1. Stand the coil section. 6-2. Lower the coil section downwards to remove Foot 1 from the notch on the Left CR Shaft Mounting Plate. 6-3. Turn the coil section counterclockwise. 6-4. Remove Torsion Spring 24.7 from the hole on the CR Scale. Figure 4-33. Removing the Torsion Spring 24.7 (2)7. Turn the CR Scale 90º, and remove it from the tab on the Left CR Shaft Mounting Plate. Figure 4-34. Removing the CR Scale Left CR Shaft Mounting Plate Torsion Spring 24.7 Tab Step 6-1 Step 6-2 Step 6-3Foot 1 Notch Tab