    of 438
    							Maintenance and Transportation231
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    Photoconductor Unit
    Handling precautions
    Always observe the following handling precautions when 
    replacing the consumable products:
    ❏The photoconductor unit weighs 2.2 kg (4.84 lb). Be sure to 
    hold it firmly by the handle when carrying it.
    ❏When replacing the photoconductor unit, avoid exposing it 
    to room light any longer than necessary. 
    ❏Be careful not to scratch the surface of the drum. Also, avoid 
    touching the drum, since oil from your skin may permanently 
    damage its surface and affect print quality.
    ❏To get the best print quality, do not store the photoconductor 
    unit in an area subject to direct sunlight, dust, salty air, or 
    corrosive gases (such as ammonia). Avoid locations subject to 
    extreme or rapid changes in temperature or humidity. 
    ❏Do not tilt the photoconductor unit.
    w
    Warning:
    ❏Do not dispose of the used consumable products in fire, as it 
    may explode and cause injury. Dispose of it according to local 
    regulations.
    ❏Keep the consumable products out of the reach of children.
     
    						
    							232Maintenance and Transportation
    Replacing the photoconductor unit
    Prepare a new photoconductor unit for replacement when you 
    get an LCD panel message informing you to do so.
    Follow the steps below to replace the photoconductor unit.
    1. Press the latch on cover B to unlock the hooks, and open cover 
    B.
    2. Open cover A.
     
    						
    							Maintenance and Transportation233
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    3. Hold the waste toner collector and draw it out. When drawing 
    out the waste toner collector, firmly pull it since it has a drag 
    resistance. Take care not to pull it too strongly as it could cause 
    you to fall down.
    Note:
    When placing the waste toner collector, stand it on a flat surface as 
    shown below to prevent the toner content from spilling out.
     
    						
    							234Maintenance and Transportation 4. Pull the lever inside the handle and turn the handle to the 
    guideline marked with the   icon.
    Note:
    If you have difficulty pulling the lever, first lift the handle slightly 
    to the left and then pull the lever again.
    5. Hold the handle of the intermediate transfer unit, and gently 
    pull it out until it stops. Make sure that the d mark of the 
    intermediate transfer unit matches that of the printer.
    c
    Caution:
    Do not touch the transfer rollers (three black cylinders) of the 
    intermediate transfer unit. Touching them may deteriorate 
    print quality.
     
    						
    							Maintenance and Transportation235
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    6. Hold the handle of the photoconductor unit and pull it out 
    while raising it.
    Note:
    Place the used intermediate transfer unit as shown below to prevent 
    contamination.
     
    						
    							236Maintenance and Transportation 7. Take the photoconductor unit out of its package.
    * Do not remove the protective sheet
    8. Place the photoconductor unit by mounting the two 
    projections near you onto the printer, and then mounting the 
    projections on the other side onto the printer.
    *
     
    						
    							Maintenance and Transportation237
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    9. Make sure the two u marks on the printer match those of the 
    photoconductor unit, and then remove the tape from the 
    photoconductor unit.
    10. Pull out the protective sheet horizontally.
     
    						
    							238Maintenance and Transportation 11. Gently insert the intermediate transfer unit until it stops.
    c
    Caution:
    Do not touch the transfer rollers (three black cylinders) of the 
    intermediate transfer unit. Touching them may deteriorate 
    print quality.
    12. Turn the handle of the intermediate transfer unit to the 
    guideline marked with the   icon.
    Note:
    ❏If you have difficulty turning the handle, pull out the 
    intermediate transfer unit again and then push it all the way 
    until it stops.
    ❏As the handle is turned to the   icon, the handle will be locked.
    13. Take a new waste toner collector out of its container.
     
    						
    							Maintenance and Transportation239
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    7
    14. Install the new waste toner collector to the printer by holding 
    it as shown below.
    Note: 
    If the waste toner collector is not installed correctly, cover A may 
    not be closed or an error massage will be displayed on the LCD panel. 
    Be sure to install the waste toner collector into the frame of the 
    printer.
    15. Close cover B. Also close the MP Tray as needed.
     
    						
    							240Maintenance and Transportation 16. Close cover A.
    w
    Warning:
    Take care not to get your finger caught in the metal part 
    inside cover A when closing it.
     
    						