Page 51

49
Cleaning the lens■Use a commercially available blower or lens
cleaning paper (for glasses and camera lenses)
for cleaning the lens. Do not use any liquid type
cleaning agents, as they may wear off the
coating film on the surface of the lens.
■ As the surface of the lens can easily get
damaged, be careful not to scrape or hit the
lens.
Cleaning the exhaust and intake vents■Use a vacuum cleaner to clean dust from the
exhaust vent and the intake vent.
Cleaning the projector■Ensure that you have...

Page 52

50
Maintenance Indicators
About the lamp indicator
■When the remaining lamp life becomes 5% or less,  (yellow) and “Change The Lamp” will be
displayed on the screen. When the percentage becomes 0%, it will change to  (red), the lamp will
automatically turn off and then the projector will automatically enter standby mode. At this time, the
lamp indicator will illuminate in red.
■ If you try to turn on the projector a fourth time without replacing the lamp, the projector will
not turn on.
About the...

Page 53

51
•If the temperature warning indicator illuminates, and the projector enters standby mode, follow the
possible solutions above and then wait until the projector has cooled down completely before plug-
ging in the power cord and turning the power back on. (At least 10 minutes.)
• If the power is turned off for a brief moment due to power outage or some other cause while using\
the projector, and the power supply recovers immediately after that, the lamp indicator will illumi-
nate in red and the lamp...

Page 54

52
Regarding the Lamp
Lamp■It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes
5% or less, or when you notice a significant deterioration in the pictur\
e and color quality. The lamp life
(percentage) can be checked with the on-screen display. (See page  47.)
■ Purchase a replacement lamp of type AH-62101 from your place of purchase, nearest EIKI Authorized
Dealer or Service Center.
Caution Concerning the Lamp■This projector utilizes a pressurized mercury...

Page 55

53
Removing and Installing
the Lamp Unit
•Do not touch the glass surface of the lamp
unit or the inside of the projector.
•T o avoid injury to yourself and damage to the
lamp, make sure you carefully follow the steps
below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
Press  STANDBY/ON  on the projec-
tor or  STANDBY  on the remote
control to put the projector into
standby mode.
•W ait until the cooling fan stops.
 W arning!
•Do not remove the lamp unit from the projec-
tor...

Page 56

54
Remove the lamp unit.•Loosen the securing screws from the
lamp unit. Hold the lamp unit and pull it
in the direction of the arrow. At this time,
keep the lamp unit horizontal and do not
tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.•P ress the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.• Align the tab on the lamp unit cover
(1 ) and place it while pressing the tab
( 2 ) to close...

Page 57

55
COMPUTER/COMPONENT input and COMPUTER/COMPONENT output Terminals : mini D-
sub 15 pin female connector
COMPUTER Input/Output Pin No. Signal
  1. Video input (red)
  2. Video input (green/sync on green)
  3. Video input (blue)
  4. Not connected
  5. Not connected
  6. Earth (red)
  7. Earth (green/sync on green)
  8. Earth (blue)
  9. Not connected
10. GND
11. Not connected
12. Bi-directional data
13. Horizontal sync signal: TTL level
14. Vertical sync signal: TTL level
15. Data clock COMPONENT...

Page 58

56
RS-232C Terminal  : mini DIN 9 pin female connector
RD
SD
SG
RS
CS
Signal Name
8
9
6 5 21 43
7Pin No.
1.
2.
3.
4.
5.
6.
7.
8.
9. I/O Reference
Not connected
Connected to internal circuit
Connected to internal circuit
Not connected
Connected to internal circuit
Not connected
Connected to CS in internal circuit
Connected to RS in internal circuit
Not connected
Receive Data
Send Data
Signal Ground
Request to Send
Clear to Send
Input
Output
RS-232C Terminal  :
 D-sub 9 pin male connector of the DIN-D-sub...

Page 59

57
Info
•When controlling the projector using RS-232C commands from a computer, wait for at least 30
seconds after the power has been turned on, and then transmit the commands.
• After sending an input selection or picture adjustment command and then receiving an “OK” re-
sponse code, the projector may take some time to process the command. If a second command is
sent while the projector is still processing the first command, you may receive an “ERR” response
code. If this happens, try resending the...

Page 60

58
is only for EIP-2600.
Computer
DVINormal
Stretch
Dot By Dot
Full
Border
Area Zoom
V-Stretch
Normal
Stretch
Dot By Dot
Full
Border
Area Zoom
V-Stretch
CONTROL CONTENTSPower ONStandby mode
(or 30-second startup time)COMMAND PARAMETERRETURN
Power
Projector Condition
Lamp
Name
Input Change
Volume
Keystone
AV Mute
Freeze
Auto Sync
Resize On
Off
Status
Status
Power Status
Quantity
Usage Time(Hour)
Usage Time(Minute)
Life(Percentage)
Model Name Check
Model Name Check
Projector Name Setting 1
(First 4...
Start reading Eiki Eip-2600 Dlp Projector Owners Manual

Related Manuals for Eiki Eip-2600 Dlp Projector Owners Manual

All Eiki manuals