Page 61

58
4Remove the lamp unit.
•Loosen the two securing screws from
the lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
5Insert the new lamp unit.
•Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
6Replace the lamp unit cover.
•Align the lamp unit cover and slide it to
close. Then tighten the user service
screw to secure the lamp unit cover.
Info
•If the lamp unit and...

Page 62

59
Connecting Pin Assignments
RS-232C Port: 9-pin D-sub male connector
Pin No. Signal Name I/O Reference
1 Not connected
2R DReceive Data Input Connected to internal circuit
3S DSend Data Output Connected to internal circuit
4 Reserved Connected to internal circuit
5S GSignal Ground Connected to internal circuit
6 Reserved Connected to internal circuit
7 Reserved Connected to internal circuit
8 Reserved Connected to internal circuit
9 Not connected
DVI-I (INPUT 5) port : 29-pin connector
•
• •
•
•  DVI...

Page 63

60
PC control
A computer can be used to control the projector by connecting an RS-232C cable (null modem, cross type,
commercially available) to the projector. (See page 27 for connection.)
Communication conditions
Set the serial port settings of the computer to match that of the table.
Signal format: Conforms to RS-232C standard.
Baud rate: 9,600 bps
Data length: 8 bits
Parity bit: None
Stop bit: 1 bit
Flow control: None
Basic format
Commands from the computer are sent in the following order: command,...

Page 64

61
Note
•This projector may not be able to display images from notebook computers\
 in simultaneous (CRT/LCD)
mode. Should this occur, turn off the LCD display on the notebook computer and output the display data
in “CRT only” mode. Details on how to change display modes can be found in y\
our notebook computer’s
owner’s manual.
Computer Compatibility Chart
•Horizontal Frequency: 15–70 kHz
Vertical Frequency: 43–75 Hz
Pixel Clock: 12–80 MHz
Compatible with sync on green
XGA compatible in intelligent...

Page 65

62
Troubleshooting
Check
• Projector power cord is not plugged into the wall outlet.
•Power to the external connected devices is off.
•The selected input mode is wrong.
•Cables are incorrectly connected to the rear panel of the projector.
•External output has not been set when connecting notebook computer.
•“Contrast” and “Bright” are set to minimum position.
•Image adjustments are incorrectly set.
(Video Input only)
• Video input system is incorrectly set.
(INPUT 5)
• Input signal type (RGB/Component)...

Page 66

63
Specifications
Product typeModel
V ideo system
Display method DLP panel
Lens
Projection lamp
V ideo input signal
S-video input signal
Component input signal (INPUT 1, 2)
Analog RGB/Digital (INPUT 5/DIGITAL)
Horizontal resolution Pixel clock
Ve rtical frequency
Horizontal frequency
Computer control signal Rated voltage
Input current
Rated frequency
Power consumption
Power consumption (standby)
Heat dissipation
Operating temperature Storage temperature
Cabinet
I/R carrier frequency
Dimensions (approx.)...

Page 67

64
Dimensions
Units: inches (mm)
M4
Side ViewSide ViewTop View
Rear View
Front View
Bottom View
M4
M4
M4
9/64 (3.5)
11
 7/64 (282)
1/16 (1.5)
2 11/64 (55.05)
12
 7/32 (310)
1 59/64 
(48.5)
3
 33/64 (89)
13/64 (5)
2
 3/16 
(55.5)
3 15/16 (99.95)
5
 7/64 (129.5)
5 7/64 (129.5)
5/8 (15.5)9/16 (14)
4 3/16 (106.3) 8
 9/32 (210.3)
8 7/8 (225.3)
1 7/32 
(30.9)
1 5/32 
(29.1)
1
 7/32 
(30.9)
1 3/4 
(44.1)
EIP-1500T_E_P62_67.p65 6/7/05, 11:01 AM
64 

Page 68

65
Glossary
Aspect Ratio
Width and height ratio of an image. The normal
aspect ratio of a computer and video image is 4:3.
There are also wide images with an aspect ratio
of 16:9 and 21:9.
Auto Sync
Optimizes projected computer images by auto-
matically adjusting certain characteristics.
Background
Initial setting image projected when no signal is
being output.
Clock
Clock adjustment is used to adjust vertical noise
when clock level is incorrect.
CLR Temp (Color temperature)
Function that can be used to...

Page 69

66
Index
A
AC socket ............................................................. 28
Adjustment buttons .............................................. 38
Aspect ratio .......................................................... 35
Auto Power Off ..................................................... 50
Auto Sync ............................................................. 46
AUTO SYNC button ............................................. 46
B
Background...

Page 70

MEMO
EIP-1500T_E_P62_67.p656/10/05, 11:16 AM
67 