Page 61
58 4Remove the lamp unit. •Loosen the two securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it. 5Insert the new lamp unit. •Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. 6Replace the lamp unit cover. •Align the lamp unit cover and slide it to close. Then tighten the user service screw to secure the lamp unit cover. Info •If the lamp unit and...
Page 62
59 Connecting Pin Assignments RS-232C Port: 9-pin D-sub male connector Pin No. Signal Name I/O Reference 1 Not connected 2R DReceive Data Input Connected to internal circuit 3S DSend Data Output Connected to internal circuit 4 Reserved Connected to internal circuit 5S GSignal Ground Connected to internal circuit 6 Reserved Connected to internal circuit 7 Reserved Connected to internal circuit 8 Reserved Connected to internal circuit 9 Not connected DVI-I (INPUT 5) port : 29-pin connector • • • • • DVI...
Page 63
60 PC control A computer can be used to control the projector by connecting an RS-232C cable (null modem, cross type, commercially available) to the projector. (See page 27 for connection.) Communication conditions Set the serial port settings of the computer to match that of the table. Signal format: Conforms to RS-232C standard. Baud rate: 9,600 bps Data length: 8 bits Parity bit: None Stop bit: 1 bit Flow control: None Basic format Commands from the computer are sent in the following order: command,...
Page 64
61 Note •This projector may not be able to display images from notebook computers\ in simultaneous (CRT/LCD) mode. Should this occur, turn off the LCD display on the notebook computer and output the display data in “CRT only” mode. Details on how to change display modes can be found in y\ our notebook computer’s owner’s manual. Computer Compatibility Chart •Horizontal Frequency: 15–70 kHz Vertical Frequency: 43–75 Hz Pixel Clock: 12–80 MHz Compatible with sync on green XGA compatible in intelligent...
Page 65
62 Troubleshooting Check • Projector power cord is not plugged into the wall outlet. •Power to the external connected devices is off. •The selected input mode is wrong. •Cables are incorrectly connected to the rear panel of the projector. •External output has not been set when connecting notebook computer. •“Contrast” and “Bright” are set to minimum position. •Image adjustments are incorrectly set. (Video Input only) • Video input system is incorrectly set. (INPUT 5) • Input signal type (RGB/Component)...
Page 66
63 Specifications Product typeModel V ideo system Display method DLP panel Lens Projection lamp V ideo input signal S-video input signal Component input signal (INPUT 1, 2) Analog RGB/Digital (INPUT 5/DIGITAL) Horizontal resolution Pixel clock Ve rtical frequency Horizontal frequency Computer control signal Rated voltage Input current Rated frequency Power consumption Power consumption (standby) Heat dissipation Operating temperature Storage temperature Cabinet I/R carrier frequency Dimensions (approx.)...
Page 67
64 Dimensions Units: inches (mm) M4 Side ViewSide ViewTop View Rear View Front View Bottom View M4 M4 M4 9/64 (3.5) 11 7/64 (282) 1/16 (1.5) 2 11/64 (55.05) 12 7/32 (310) 1 59/64 (48.5) 3 33/64 (89) 13/64 (5) 2 3/16 (55.5) 3 15/16 (99.95) 5 7/64 (129.5) 5 7/64 (129.5) 5/8 (15.5)9/16 (14) 4 3/16 (106.3) 8 9/32 (210.3) 8 7/8 (225.3) 1 7/32 (30.9) 1 5/32 (29.1) 1 7/32 (30.9) 1 3/4 (44.1) EIP-1500T_E_P62_67.p65 6/7/05, 11:01 AM 64
Page 68
65 Glossary Aspect Ratio Width and height ratio of an image. The normal aspect ratio of a computer and video image is 4:3. There are also wide images with an aspect ratio of 16:9 and 21:9. Auto Sync Optimizes projected computer images by auto- matically adjusting certain characteristics. Background Initial setting image projected when no signal is being output. Clock Clock adjustment is used to adjust vertical noise when clock level is incorrect. CLR Temp (Color temperature) Function that can be used to...
Page 69
66 Index A AC socket ............................................................. 28 Adjustment buttons .............................................. 38 Aspect ratio .......................................................... 35 Auto Power Off ..................................................... 50 Auto Sync ............................................................. 46 AUTO SYNC button ............................................. 46 B Background...