Digital Projection Titan Xg-500 User Manual
Have a look at the manual Digital Projection Titan Xg-500 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 577 Digital Projection manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Rev B 02/2007 Page 4.9 Digital Projection TITAN XG-500 User Manual 4. Controlling the projector The remote control Layout Timeout There is a 10 second timeout for the three Lens adjustment keys (see note on next page). There is a separate, adjustable timeout for the On Screen Menus (see On Screen Display, in Setup Menu, later in this section). Notes Many features are controlled from the menus using the menu navigation keys on the remote control or keypad. For more information about using the menus, see later in this section, Using the menus. Some of the menu features, for example brightness, contrast and input preset operations, can be accessed directly using the control keys at the bottom of the remote control. Other features, eg zoom and focus, are controlled using the control keys at the top of the remote control and keypad. For more information about using the control keys, see later in this section, Using the control keys. The following keys are NOT used on this projector: CTRL R P Y FUNC 10+ (but N is used) # (but R is used) Note that plugging in the remote control cable will disable the infra-red. Menu navigation keys Remote control backlight ON/OFFControl keys Transmit indicator
Page 4.10 Rev B 02/2007 4. Controlling the projector Digital Projection TITAN XG-500 User Manual Notes Closing the shutter produces a better black than simply removing the signal, as the light source will be completely blocked by the shutter blade. When the OSD is OFF: - all menu navigation keys are disabled. - keys such as BRI (brightness) will still function, but the slider bars will not be visible on screen. When any of the three Lens adjustment keys is pressed, the blue Transmit indicator on the remote control will light for 10 seconds: - after 10 seconds, if no adjustment has been made, the indicator will go out and the Lens adjustment key must be pressed again to resume adjustment. - to end the adjustment before 10 seconds has elapsed, press the key. - all other adjustments will be locked out until the Lens adjustment is ended. For more information about the amount of lens shift available, see section 2. Installation. Using the control keys Power Press POWER and hold for 3 seconds, to switch the projector ON. Press POWER and hold for 3 seconds, to switch the projector OFF. Shutter Press SHUTTER to OPEN the shutter. Press SHUTTER to CLOSE the shutter. On-Screen-Display Press OSD to switch the On-Screen-Display OFF. This includes ALL menus, controls and on-screen messages. Press OSD to switch the On-Screen-Display ON. Focus Press followed by and to adjust the focus. When adjustment is fi nished, press . Zoom Press followed by and to adjust the zoom. When adjustment is fi nished, press . Shift Press followed by , , or to shift the lens up, down, left or right. When adjustment is fi nished, press . • • • • • • • • •
Rev B 02/2007 Page 4.11 Digital Projection TITAN XG-500 User Manual 4. Controlling the projector Auto-detect input mode Press to force the projector to re-detect the input mode (see Input modes and settings, earlier in this section). Source information Press to display the source information screen. Input Press or to change to the next input up or down the following list: 1. RGB1 2. RGB2 3. DVI 4. (not used in this projector) 5. Composite Video 6. S-Video 7. Component Or press the numbered keys 1–7 to change directly to the input: • • • • Notes For more information about input mode detection, see earlier in this section, Input modes and settings. Input 4. is not used on this projector.
Page 4.12 Rev B 02/2007 4. Controlling the projector Digital Projection TITAN XG-500 User Manual Notes For more information about input modes and input presets, see earlier in this section, Input modes and settings. A preset can be applied only to the same mode for which it was created. If the detected input mode does not match, then settings from the mode history or mode library will be applied. For more information about input modes, see Input modes and settings. earlier in this section. Input Presets Recall To recall a set of modal settings that have been saved, press and hold , whilst pressing the lettered key A – S. The projector will switch to the saved input source, and redetect the input mode before applying the saved modal settings. Save To save the current input source, mode and modal settings, press and hold , whilst pressing the lettered key A – S. If this Preset has been used before, and the Input source has been changed, then the following message will be displayed. Press and to select either OK or Cancel. Press to confi rm your selection. The modal settings will be saved to the selected preset, and the following message will be displayed. • • • • • •
Rev B 02/2007 Page 4.13 Digital Projection TITAN XG-500 User Manual 4. Controlling the projector Notes The red, green and blue keys are disabled when the OSD is switched OFF. The Saturation control is available for Composite, S- Video and Component inputs only. The Phase control is available for RGB inputs only. For all adjustments on this page that require more than one key to be pressed: - after 10 seconds, if no adjustment has been made, the key must be pressed again to resume adjustment. - to end the adjustment before 10 seconds has elapsed, press a different adjustment key, or press the key. When the OSD is OFF: - the keys will still function, but the controls will not be visible on screen. Red, Green and Blue Press , or to switch the red, green or blue components OFF or ON. Test pattern Press to select a test pattern. Picture settings Press a key, followed by and to adjust these picture settings: Brightness BRI Contrast CON Saturation SAT Phase PHASE Aspect ratio ASPECT Geometry settings Keystone adjustment is used to correct for distortion caused by the projector being mounted higher or lower than the screen. Press Keystone KEYST, followed by and to adjust the keystone correction: Press Position POS, followed by , , and to adjust the picture position, for images smaller than the DMD: • • • • •
Page 4.14 Rev B 02/2007 4. Controlling the projector Digital Projection TITAN XG-500 User Manual Notes The magnify feature utilises a digital zoom. Used with the pan control, this can be used to: - enlarge a section of the image - enable the use of multiple projectors to construct a large image from tiles. The pan control is available only when the image has been magnifi ed. If the OSD moves off screen due to a change in image size, then pressing the size key will restore its readability. When fresh batteries are inserted in the remote control it will default to address 00. Remote control 00 is a master control, able to control all projectors. If two or more projectors are set to the same address, they can be controlled from one remote control, provided they are connected by cable or in range of the infra red. Magnify and pan Press Magnify MAGNIFY followed by and to adjust the size of the picture. Press Pan PA N followed by , , and to adjust the position of the magnifi ed image. On-screen-display size Press Size SIZE to switch the size of the OSD between large and small. Remote control address The projector and the remote control need to be set to matching addresses. Read the note to the right on this page, and follow the instructions in the order shown below: 1 Set the projector address as shown in Setup menu, later in this section. 2 Set the remote control address: Press and hold whilst pressing two numbered keys 0 – 9 to set the remote control address to any number between 00 and 99. (leading zeros must be used for numbers less than 10) Remote control backlight Press to switch the backlight on and off. • • • • •
Rev B 02/2007 Page 4.15 Digital Projection TITAN XG-500 User Manual 4. Controlling the projector Notes Some menu controls can be accessed directly using the control keys (see earlier in this section). When the OSD is OFF, all menu navigation keys will be disabled. When the OSD is switched back ON, the menus will remain OFF until the key is pressed again. The menus will then reopen at the same point they were last viewed. If a menu is opened, and no other key is pressed within the period set in the OSD Timeout menu, then the menus will disappear. When the key is pressed again, the menus will reopen at the same point they were last viewed. (see On Screen Display, in Setup Menu, later in this section).) Main menu: Input Input 4. is not used on this projector. Main menu: Setup Using the menus Navigating menus and submenus When the menus are in use and the OSD is ON, the top level menu headings are always visible to the left of the screen. Each menu item can lead to a number of submenus, which are displayed in the column to the right . The symbol indicates that a submenu is available. Each submenu can lead to further submenus, up to a maximum of three levels. To display the menus, press on the remote control or the keypad. The menus will always open at the same point they were last viewed. The example below shows the fi rst menu display following power on – the item that is currently selected (the Input menu) is highlighted in blue. To select a menu, press and , for example the Setup menu: • • •
Page 4.16 Rev B 02/2007 4. Controlling the projector Digital Projection TITAN XG-500 User Manual Press to open the menu. The blue highlight moves to the fi rst item in the menu, which may be submenu, for example the Projector Setup submenu. To select a submenu, press and , for example the Lamp submenu. Press to open the submenu. The submenu opens, with the title at the top. To close the submenu and return to the previous level, press . There may be up to three levels of submenu, so to return to the top level, you may have to press up to three times. To close the menu display completely, press . • • •• Notes Setup menu Setup menu Lamp Setup menu
Rev B 02/2007 Page 4.17 Digital Projection TITAN XG-500 User Manual 4. Controlling the projector Slider bar The highlighted slider bar shows which control is active currently. To adjust the slider press and . Parameter selection To select from a number of parameters, (shown one at a time to the right), press and . These two items are greyed out and the values are blank, showing that they are not available, due to the effect of settings made in other menus, or due to the type of input signal. Parameter list To select from a list of parameters, press and . Menu controls Some menus have controls, as shown in the examples below. Notes Some menus items may be greyed out - unavailable due to the effect of settings made in other menus, or due to the type of input signal.
Page 4.18 Rev B 02/2007 4. Controlling the projector Digital Projection TITAN XG-500 User Manual Input menu To return to the main menu, press up to three times. From the main menu: Press and until Input is highlighted. Press to open the Input menu. The blue highlight moves to the fi rst item in the menu. The symbol shows which input is currently selected. Input Source Press and to select from: 1. RGB1 2. RGB2 3. DVI 4. (not used in this projector) 5. Composite Video 6. S-Video 7. Component Press to confi rm your selection. • •• Notes Some menu controls can be accessed directly using the control keys (see earlier in this section). When using the menus, press OSD or to hide or reveal the On-Screen-Display. Input Menu Input 4. is not used on this projector. For more information about the input connections, see section 2. Installation, and section 7. Appendix. When an input has been selected, the projector will automatically detect input mode settings such as line rate and resolution etc. To force the projector to re- detect the input mode settings, press .