Digital Projection Lightning 30sx+m, 40sx+m User Manual
Here you can view all the pages of manual Digital Projection Lightning 30sx+m, 40sx+m User Manual. The Digital Projection manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 91
page 6.21 105-681B January 2007 Digital Projection LIGHTNING 30sx+m, 40sx+m User Manual 6. Appendix Lens Commands Lens Stop All Used to stop all lens motors. CALL : lens,stop,write RETURNS : [msg id],ACK,stop : OR : [msg id],NAK,stop Lens Move Used to move lens position left-right, up-down and open/close shutter. CALL : lens,move,write,[axis],[direction],[time],[speed] : Where [axis] is one of: : h - horizontal : v - vertical : f - focus : z - zoom : s - shutter : [direction is one of: : l - left...
Page 92
page 6.22 105-681B January 2007 6. Appendix Digital Projection LIGHTNING 30sx+m, 40sx+m User Manual Lens Goto Absolute Position Used to move lens to absolute co-ordinates. CALL : lens,goto,write,h,[hpos],v,[vpos],f,[fpos],z,[zpos] : Where hpos, vpos, fpos and zpos are values probably obtained from a goto read NOTE : Any one or all axis may be driven at the same time. RETURNS : [msg id],ACK,goto : OR : [msg id],NAK,goto CALL : lens,goto,read,[urgency switch] NOTE : Urgency switch is currently...
Page 93
page 6.23 105-681B January 2007 Digital Projection LIGHTNING 30sx+m, 40sx+m User Manual 6. Appendix PSU Commands Lamp On Used to turn Lamp on and query Lamp state. CALL : lpsu,on,write,[lamp number] NOTE : Lamp number currently ignored but must be present : (can be set to 0). RETURNS : [msg id],ACK,on : [msg id],NAK,on CALL : lpsu,on,read,[urgency switch],[lamp number] NOTE : Urgency switch and lamp number currently ignored : but must be present (can be set to 0). RETURNS : [msg id],lpsu,on : OR :...
Page 94
page 6.24 105-681B January 2007 6. Appendix Digital Projection LIGHTNING 30sx+m, 40sx+m User Manual Lamp Power Used to set and query Lamp power level. CALL : lpsu,power,write,[lamp number],[% power] NOTE : Lamp number currently ignored but must be present : (can be set to 0). RETURNS : [msg id],ACK,power : [msg id],NAK,power CALL : lpsu,power,read,[urgency switch],[lamp number] NOTE : Urgency switch and lamp number currently ignored but must be present (can be set to 0). RETURNS : [msg id],power,[%...
Page 95
page 6.25 105-681B January 2007 Digital Projection LIGHTNING 30sx+m, 40sx+m User Manual 6. Appendix Dimensions All dimensions in mm
Page 96
page 6.26 105-681B January 2007 6. Appendix Digital Projection LIGHTNING 30sx+m, 40sx+m User Manual