    							Removing a cooling fan
    Prerequisites
    1.Follow the safety guidelines listed in the Safety instructions section.
    2.Follow the procedure listed in the Before working inside your system section.
    CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and 
    simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support  team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
    CAUTION: The cooling fans are hot-swappable. To maintain proper cooling while the system is on, replace only one fan at 
    a time.
    NOTE: The procedure for removing each fan is identical.
    Steps
    Press the fan release tab and lift the cooling fan out of the cooling fan assembly.
    Figure 23. Removing a cooling fan
    1.cooling fan assembly2.cooling fan connector (6)3.fan release tab (6)4.cooling fan (6)5.cooling fan connector on the system board (6)
    Next steps
    1.Install the cooling fan.
    2.Follow the procedure listed in the After working inside your system section.
    Related links
    Safety instructions
    Before working inside your system
    Installing a cooling fan
    After working inside your system
    71 
    						
    							Installing a cooling fan
    Prerequisites
    CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and 
    simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support  team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
    1.Follow the safety guidelines listed in the Safety instructions section.
    2.Follow the procedure listed in the Before working inside your system section. 
    NOTE: Your system supports six hot swappable cooling fans.
    NOTE: The procedure for installing each fan is identical.
    Steps
    1.Align the connector at the base of the cooling fan with the connector on the system board.
    2.Slide the cooling fan into the securing slot until the tab locks into place.
    Figure 24. Installing a cooling fan
    1.cooling fan assembly2.cooling fan connector (6)3.fan release tab (6)4.cooling fan (6)5.cooling fan connector on the system board (6)
    Next steps
    Follow the procedure listed in the After working inside your system section.
    Related links
    Safety instructions
    Before working inside your system
    After working inside your system
    72 
    						
    							Cooling fan assembly
    The cooling fan assembly is an essential part of a server
    						
    							2.Follow the procedure listed in the After working inside your system section.
    Related links
    Safety instructions
    Before working inside your system
    Installing the cooling fan assembly
    After working inside your system
    Installing the cooling fan assembly
    Prerequisites
    CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and 
    simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support  team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
    1.Follow the safety guidelines listed in Safety instructions section.
    2.Follow the procedure listed in the Before working inside your system section.
    CAUTION: Ensure that the cables are correctly installed and retained by the cable retention bracket before installing the 
    cooling fan assembly. Incorrectly installed cables may get damaged.
    Steps
    1.Align the slots on the cooling fan assembly with the guide pins on the chassis.
    2.Slide the cooling fan assembly into the chassis.
    3.Lock the cooling fan assembly into the chassis by lowering the release levers until  
    						
    							5.cooling fan connector (6)6.guide pin on the chassis (6)
    Next steps
    Follow the procedure listed in the After working inside your system section.
    Related links
    Safety instructions
    Before working inside your system
    After working inside your system
    System memory
    The system supports DDR4 registered DIMMs (RDIMMs) and load reduced DIMMs (LRDIMMs). System memory holds the instructions that are executed by the processor.
    NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
    Memory bus operating frequency can be 1866 MT/s, 2133 MT/s, or 2400 MT/s depending on the following factors:
    
    						
    							Figure 27. Memory socket locations
    Memory channels are organized as follows:
    Table 35. Memory channelsProcessorChannel 0Channel 1Channel 2Channel 3Processor 1Slots A1, A5, and A9Slots A2, A6, and A10Slots A3, A7, and A11Slots A4, A8, and A12Processor 
    2Slots B1, B5, and B9Slots B2, B6, and B10Slots B3, B7, and B11Slots B4, B8, and B12
    The following table shows the memory populations and operating frequencies for the supported  con
    						
    							DIMM TypeDIMMs Populated/
    ChannelVoltageOperating Frequency (in  MT/s)Maximum DIMM Rank/
    Channel22400, 2133, 1866Quad rank32133, 1866Quad rank
    General memory module installation guidelines
    NOTE: Memory  configurations  that fail to observe these guidelines can prevent your system from booting, stop 
    responding during memory  configuration, or operating with reduced memory.
    The system supports Flexible Memory  Con
    						
    							In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on a rank, the data from this rank is copied to the spare rank, and the failed rank is disabled.
    With memory sparing enabled, the system memory available to the operating system is reduced by one rank per channel. For example, in a dual-processor  con
    						
    							System 
    capacity (in 
    GB)DIMM size 
    (in GB)Number of 
    DIMMsDIMM rank, organization, and frequencyDIMM slot population1R, x8, 2133 MT/s484121R, x8, 1866 MT/sA1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, 
    A12861R, x8, 2400 MT/s
    1R, x8, 2133 MT/s
    A1, A2, A3, A4, A5, A6968121R, x8, 1866 MT/sA1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A121662R, x8, 2400 MT/s
    2R, x8, 2133 MT/s
    A1, A2, A3, A4, A5, A61281682R, x8, 2400 MT/s
    2R, x8, 2133 MT/s
    A1, A2, A3, A4, A5, A6, A7, A812814R, x4, 2400 MT/sA11448101R, x8, 1866 MT/sA1, A2, A3, A4, A5, A6, A7, A8, A9, A11* 16102R, x8, 1866 MT/sA1, A2, A3, A4, A5, A6, A7, A8, A9, A11* 2563282R, x4, 2400 MT/s
    2R, x4, 2133 MT/s
    A1, A2, A3, A4, A5, A6, A7, A812824R, x4, 2400 MT/sA1, A238432122R, x4, 1866 MT/sA1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A125126484R, x4, 2133 MT/s
    4R, x4, 2400 MT/s
    A1, A2, A3, A4, A5, A6, A7, A812844R, x4, 2400 MT/sA1, A2, A3, A476864124R, x4, 1866 MT/s
    4R, x4, 2133 MT/s
    A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, 
    A1212864R, x4, 2400 MT/sA1, A2, A3, A4, A5, A61536128124R, x4, 2133 MT/s
    4R, x4, 1866 MT/s
    A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12
    * 16 GB DIMMs must be installed in slots numbered A1, A2, A3, A4, A5, A6, A7, and A8 and 8 GB DIMMs must be installed in slots A9 
    and A11.
    79 
    						
    							Table 39. Memory configurations
    						