    of 418
    							DRAC 5 Property Database Group and Object Definitions401
    Description
    Enables or disables line editing on the IPMI serial interface.
    cfgIpmiSerialEchoControl (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE)
    1 (TRUE)
    Default
    1
    Description
    Enables or disables echo control on the IPMI serial interface.
    cfgIpmiSerialDeleteControl (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE)
    1 (TRUE)
    Default
    0
    Description
    Enables or disables delete control on the IPMI serial interface.
    cfgIpmiSerialNewLineSequence (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (None) 
    						
    							402DRAC 5 Property Database Group and Object Definitions
    1 (CR-LF)
    2 (NULL)
    3 ()
    4 ()
    5 ()
    Default
    1
    Description
    Specifies the newline sequence specification for the IPMI serial interface.
    cfgIpmiSerialInputNewLineSequence (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 ()
    1 (NULL)
    Default
    1
    Description
    Specifies the input newline sequence specification for the IPMI serial interface.
    cfgIpmiSol
    This group is used to configure the Serial-Over-LAN capabilities of the system.
    cfgIpmiSolEnable (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE) 
    						
    							DRAC 5 Property Database Group and Object Definitions403
    1 (TRUE)
    Default
    1
    Description
    Enables or disables Serial Over LAN (SOL).
    cfgIpmiSolBaudRate (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    9600, 19200, 57600, 115200
    Default
    57600
    Description
    The baud rate for serial communication over LAN.
    cfgIpmiSolMinPrivilege (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    2 (User)
    3 (Operator)
    4 (Administrator)
    Default
    4
    Description
    Specifies the minimum privilege level required for serial over LAN access. 
    						
    							404DRAC 5 Property Database Group and Object Definitions
    cfgIpmiSolAccumulateInterval (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    1 – 255.
    Default
    10
    Description
    Specifies the typical amount of time that the BMC waits before transmitting a 
    partial SOL character data packet. This value is 1-based 5ms increments.
    cfgIpmiSolSendThreshold (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    1 – 255
    Default
    255
    Description
    The SOL threshold limit value.
    cfgIpmiLan
    This group is used to configure the IPMI-Over-LAN capabilities of the system.
    cfgIpmiLanEnable (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE)
    1 (TRUE) 
    						
    							DRAC 5 Property Database Group and Object Definitions405
    Default
    1
    Description
    Enables or disables the IPMI-Over-LAN interface.
    cfgIpmiLanPrivLimit (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    2 (User)
    3 (Operator)
    4 (Administrator)
    Default
    0
    Description
    Specifies the maximum privilege level allowed for IPMI over LAN access.
    cfgIpmiLanAlertEnable (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE)
    1 (TRUE)
    Default
    1
    Description
    Enables or disables global e-mail alerting. This property overrides all individual 
    e-mail alerting enable/disable properties. 
    						
    							406DRAC 5 Property Database Group and Object Definitions
    cfgIpmiEncryptionKey (Read/Write)
     NOTE: To view or modify this property, you must have Configure DRAC 5 permission 
    and administrator privileges.
    Legal Values
    A string of hexadecimal digits from 0 to 20 characters with no spaces.
    Default
    00000000000000000000
    Description
    The IPMI encryption key.
    cfgIpmiPetCommunityName (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    A string up to 18 characters.
    Default
    public
    Description
    The SNMP community name for traps. 
    cfgIpmiPef
    This group is used to configure the platform event filters available on the 
    managed server.
    The event filters can be used to control policy related to actions that are 
    triggered when critical events occur on the managed system. 
    						
    							DRAC 5 Property Database Group and Object Definitions407
    cfgIpmiPefName (Read Only)
    Legal Values
    String. Maximum Length = 255.
    Default
    The name of the index filter.
    Description
    Specifies the name of the platform event filter.
    cfgIpmiPefIndex (Read Only)
    Legal Values
    1 – 17
    Default
    The index value of a platform event filter object.
    Description
    Specifies the index of a specific platform event filter.
    cfgIpmiPefAction (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (None)
    1 (Power Down)
    2 (Reset)
    3 (Power Cycle)
    Default
    0 
    						
    							408DRAC 5 Property Database Group and Object Definitions
    Description
    Specifies the action that is performed on the managed system when the alert is 
    triggered.
    cfgIpmiPefEnable (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE)
    1 (TRUE)
    Default
    1
    Description
    Enables or disables a specific platform event filter.
    cfgIpmiPet
    This group is used to configure platform event traps on the managed system.
    cfgIpmiPetIndex (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    1 – 4
    Default
    The appropriate index value.
    Description
    Unique identifier for the index corresponding to the trap.
    cfgIpmiPetAlertDestIpAddr (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission. 
    						
    							DRAC 5 Property Database Group and Object Definitions409
    Legal Values
    String representing a valid IP address. For example, 192.168.0.67.
    Default
    0.0.0.0
    Description
    Specifies the destination IP address for the trap receiver on the network. 
    The trap receiver receives an SNMP trap when an event is triggered on the 
    managed system.
    cfgIpmiPetAlertEnable (Read/Write)
     NOTE: To modify this property, you must have Configure DRAC 5 permission.
    Legal Values
    0 (FALSE)
    1 (TRUE)
    Default
    1
    Description
    Enables or disables a specific trap.
    cfgLogging
    This group is used to enable or disable the OEM event log filtering.
    cfgLoggingSELOEMEventFilterEnable (Read/Write)
    Legal Values 
    0 (SEL Log filtering is Disabled)
    1 (SEL Log filtering is Enabled) 
    						
    							410DRAC 5 Property Database Group and Object Definitions
    Default 
    0
    Description
    Enables or disables the SEL Log filtering. 
    						