    							Using GUI Console Redirection171
    Adjusting the Video Quality
    The Video Viewer provides video adjustments that allow you to optimize 
    the video for the best possible view. Click Help for more information.
    To automatically adjust the video quality:
    1
    Access the Viewer Menu Bar. See Accessing the Viewer Menu Bar on 
    page 168.
    2Click Tools and select Automatic Video Adjust (for Native plug-in) or 
    Video Settings (for Java plug-in) to automatically adjust the video quality 
    of the Viewer window.
    To manually adjust the video quality:
    1
    Access the Viewer Menu Bar. See Accessing the Viewer Menu Bar on 
    page 168.
    2Click Tools and select Manual Video Adjust (for Native plug-in) or Vi d e o  
    Settings
     (for Java plug-in).
    3In the Manual Video Adjust window, click each video adjustment button 
    and adjust the controls as needed. 
    4When finished, click Close to exit the Manual Video Adjust dialog box.
    When you manually adjust the video quality, observe the following 
    guidelines:
    • To prevent the mouse pointers from desynchronizing, adjust the horizontal 
    setting so the remote system’s desktop is centered in the session window.
    • Reducing the Pixel Noise Ratio setting to zero causes multiple video 
    refresh commands that generates excessive network traffic and flickering 
    video in the 
    Video Viewer window. Dell recommends that you adjust the 
    Pixel Noise Ratio setting at a level that provides optimal system 
    performance and pixel enhancement while minimizing network traffic.  
    						
    							172Using GUI Console Redirection
    Synchronizing the Mouse Pointers
    When you connect to a remote Dell system using Console Redirection, the 
    mouse acceleration speed on the remote system may not synchronize with 
    the mouse pointer on your management station, causing two mouse pointers 
    to appear in the Video Viewer window.
    To synchronize the mouse pointers:
    1
    Access the Viewer Menu Bar. See Accessing the Viewer Menu Bar on 
    page 168.
    2Click Tools and select Session Options.
    3Click the Mouse tab, select your management station’s operating system, 
    and click 
    OK.
    4Click Tools and select Manual Video Adjust.
    5Adjust the horizontal controls so the remote system’s desktop appears in 
    the center of the session window.
    6Click OK.
    When using Linux (Red Hat or Novell), the operating system’s default mouse 
    settings are used to control the mouse arrow in the DRAC 5 Console 
    Redirection screen.
     NOTE: On Linux (Red Hat or Novell) systems, there are known mouse arrow 
    synchronization issues. To minimize mouse synchronization problems, ensure that 
    all users use the default mouse settings.
    For information on disabling the console redirection, see Disabling DRAC 5 
    Remote Virtual KVM on page 214. 
    						
    							Using GUI Console Redirection173
    Using Power Control Option
    The Power Control option allows you to do the following on the managed 
    system:
    • Power on the system
    • Power off the system
    • Reset the system
    • Power cycle the system
    To control power on the managed system:
    1
    Access the Viewer Menu Bar. See Accessing the Viewer Menu Bar on 
    page 168.
    2Click Tools and then click Po w e r Co n t r ol.
    3Click any of the options provided:
    • Power on the system.
    • Power off the system.
    • Reset the system. Restart the system without powering it off.
    • Power cycle the system. Restart the system after powering it off.
    A pop-up window is displayed.
    4Click Ye s and click OK.
    Frequently Asked Questions
    Can a new remote console video session be started when the local video on 
    the server is turned OFF?
    Ye s .
    Why does it take 15 seconds to turn OFF the local video on the server after 
    requesting to turn OFF the local video?
    It gives a local user an opportunity to take any action before the video is 
    switched OFF.
    Is there a time delay when turning ON the local video?
    No, once a local video turn ON request is received by DRAC 5 the video is 
    turned ON instantly. 
    						
    							174Using GUI Console Redirection
    Can the local user also turn OFF the video?
    Yes, a local user can use racadm CLI (local) to turn OFF the video.
    Can the local user also turn ON the video?
    Yes, the user should have racadm CLI installed on the server and only if the 
    user is able to access the server over an RDP connection, such as terminal 
    services, telnet, or SSH. The user can then log on to the server and can run 
    racadm (local) to turn ON the video.
    My local video is turned OFF and for some reason my DRAC 5 is not 
    accessible remotely and the server is not accessible with RDP, telnet, or 
    SSH. How do I recover the local video?
    The only way to recover the local video in this case is by removing the 
    AC power cord from the server, draining the server flee power and 
    reconnecting the AC power cord; this will bring back the local video on 
    the server monitor. Also, the DRAC 5 configuration is changed to local 
    video ON (default). The DRAC 5 needs to be reconfigured if the local 
    video needs to be turned OFF again.
    Does switching OFF the local video also switch OFF the local keyboard and 
    mouse?
    No, switching OFF the local video only switches OFF the video going from 
    the server’s monitor output connector; it will not switch off the keyboard and 
    mouse connected locally to the server.
    Does turning off the local server video turn off the video on the remote 
    vKVM session?
    No, turning the local video ON or OFF is independent of the remote console 
    session.
    What privileges are needed for a DRAC 5 user to turn ON or OFF the local 
    server video?
    Any user with DRAC 5 configuration privileges can turn the local server video 
    ON or OFF.
    How can I get the current status of the local server video? 
    						
    							Using GUI Console Redirection175
    The status is displayed on the Console Redirection Configuration page of 
    the DRAC 5 web-based interface. The racadm CLI command racadm 
    getconfig –g cfgRacTuning displays the status in the object 
    cfgRacTuneLocalServerVideo. The status is also seen by the local user on the 
    server LCD screen as “Video OFF” or as “Video OFF in 15”.
    Why is it that sometimes I do not see the “Video OFF” or “Video OFF in 
    15” status on the server LCD screen?
    The local video status is a low-priority message and will get masked if a high 
    priority server event has occurred. The LCD messages are based on priority; 
    you must resolve any high-priority LCD messages and once that event is 
    cleared or resolved, the next low priority message is displayed. The server 
    video message on the LCD screen is informational in nature.
    Where can I get more information on the Local Server Video feature?
    See the Dell Support website at support.dell.com/manuals for a white paper 
    discussing this feature.
    I see video corruption on my screen. How do I fix this issue?
    In the Console Redirection window, click Refresh to refresh the screen. 
     NOTE: You may need to click Refresh several times to correct the video corruption.
    During Console Redirection, the keyboard and mouse are locked after 
    hibernation on a Windows 2000 system. What caused this to happen?
    To resolve this issue, reset the DRAC 5 by running the racadm racreset 
    command.
    I cannot see the bottom of the system screen from the Console Redirection 
    window.
    Ensure that the management station’s monitor resolution is set to 
    1280x1024.
    During Console Redirection, the mouse is locked after hibernation on a 
    Windows Server 2003 system. Why did this happen?
    To resolve this issue, select an operating system other than Windows for 
    mouse acceleration from the virtual KVM (vKVM) window pull-down menu, 
    wait 5 to 10 seconds, and then select Windows again. If the problem is not 
    resolved, you must reset the DRAC 5 by running the racadm racreset 
    command. 
    						
    							176Using GUI Console Redirection
    If the problem is still not resolved, you must reset the DRAC 5 by running the 
    racadm racreset hard command.
    Why aren’t the vKVM keyboard and mouse working?
    You must set the USB controller to On with BIOS support in the BIOS 
    settings of the managed system. Restart the managed system and press  
    to enter setup. Select Integrated Devices, and then select USB Controller. 
    Save your changes and restart the system.
    Why does the managed system console screen go blank when Windows has a 
    blue screen?
    The managed system does not have the correct ATI video driver. You must 
    update the video driver with the Dell Systems Management Tools and 
    Documentation DVD.
    Why do I get a blank screen on the remote console after completing a 
    Windows 2000 installation?
    The managed system does not have the correct ATI video driver. The 
    DRAC 5 Console Redirection will not run correctly on the SVGA video driver 
    on the Windows 2000 distribution CD. You must install Windows 2000 
    using the Dell Systems Management Tools and Documentation DVD to ensure 
    that you have the latest, supported drivers for the managed system.
    Why do I get a blank screen on the managed system when loading the 
    Windows 2000 operating system?
    The managed system does not have the correct ATI video driver. You must 
    update the video driver by using the Dell Systems Management Tools and 
    Documentation DVD.
    Why do I get a blank screen on the managed system in the Windows full 
    screen DOS window?
    The managed system does not have the correct ATI video driver. You must 
    update the video driver by using the Dell Systems Management Tools and 
    Documentation DVD.
    Why can’t I enter BIOS setup by pressing the  key?
    This behavior is typical in a Windows environment. Use your mouse to click 
    on an area of the Console Redirection window to adjust the focus. To move 
    the focus to the bottom menu bar of Console Redirection window, use the 
    mouse and click one of the objects on the bottom menu bar. 
    						
    							Using GUI Console Redirection177
    Why doesn’t the vKVM mouse sync when I use the Dell Systems 
    Management Tools and Documentation DVD to remotely install the 
    operating system?
    Configure Console Redirection for the operating system that is running on 
    the target system.
    1
    In the vKVM toolbar menu, click Tools and select Session Options.
    2In the Session Options window, click the Mouse tab.
    3In the Mouse Acceleration box, select the operating system that is running 
    on the target system and click 
    OK.
    Why doesn’t the vKVM mouse sync after coming back from hibernation on 
    a Windows system?
    Select a different operating system for mouse acceleration on the vKVM 
    window pull-down menu. Next, return to the original operating system to 
    initialize the USB mouse device.
    1
    In the vKVM toolbar, click Tools and select Session Options.
    2In the Session Options window, click the Mouse tab.
    3In the Mouse Acceleration box, select another operating system and 
    click
    OK.
    4Initialize the USB mouse device.
    Why doesn’t the mouse sync in DOS when performing Console 
    Redirection?
    The Dell BIOS is emulating the mouse driver as a PS/2 mouse. By design, the 
    PS/2 mouse uses relative position for the mouse pointer, which causes the 
    sync lag. DRAC 5 has a USB mouse driver, which allows absolute position and 
    closer tracking of the mouse pointer. Even if DRAC 5 passes the USB 
    absolute mouse position to the Dell BIOS, the BIOS emulation would 
    convert it back to relative position and retain the behavior.
    Why doesn’t the mouse sync under the Linux text console?
    Virtual KVM requires the USB mouse driver, but the USB mouse driver is 
    available only under the X-Window operating system. 
    						
    							178Using GUI Console Redirection
    I am still having issues with mouse synchronization.
    Ensure that the target system’s desktop is centered in the console redirection 
    window.
    1
    In the vKVM toolbar, click Tools and select Manual Video Adjustment.
    2Adjust the horizontal and vertical controls as needed to align the desktop 
    in the console redirection window.
    3Click Close.
    4Move the target system’s mouse cursor to the top left corner of the console 
    redirection window, and then move the cursor back to the center of the 
    window.
    5Repeat step 2 through step 4 until both cursors are synchronized.
    Why doesn’t the vKVM mouse and keyboard work when changing mouse 
    acceleration for different operating systems?
    The USB vKVM keyboard and mouse are inactive from 5 to 10 seconds after 
    changing the mouse acceleration. The network load can sometimes cause this 
    operation to take longer than normal (more than 10 seconds).
    Why cant I see the bottom of the server screen from the vKVM window?
    Ensure that the server screen resolution is 1280 x 1024 pixels at 60 Hz with 
    128 colors.
    Why cant I use a keyboard or mouse while installing a Microsoft operating 
    system remotely by using DRAC5 Console Redirection?
    When you remotely install a supported Microsoft operating system on a 
    system with Console Redirection enabled in the BIOS, you receive an EMS 
    Connection Message that requires you to select OK before you can continue. 
    You cannot use the mouse to select OK remotely. You must either select OK 
    on the local system or restart the remotely managed system, reinstall, and 
    then turn Console Redirection Off in the BIOS.
    This message is generated by Microsoft to alert the user that Console 
    Redirection is enabled. To ensure that this message does not appear, always 
    turn off Console Redirection in the BIOS before installing an operating 
    system remotely. 
    						
    							Using GUI Console Redirection179
    Why does console redirection fail to show the operating system boot menu 
    in the Chinese, Japanese, and Korean versions of Microsoft Windows 2000?
    On systems running Windows 2000 that can boot to multiple operating 
    systems, change the default boot operating system by performing the 
    following steps:
    1
    Right-click the My Computer icon and select Properties.
    2Click the Advanced tab.
    3Click Startup and Recovery.
    4Select the new default operating system from the Startup list.
    5In the Show list for box, type the number of seconds that the list of choices 
    should be displayed before the default operating system automatically 
    boots.
    Why doesn’t the Num Lock indicator on my management station reflect the 
    status of the Num Lock on the remote server?
    When accessed through the DRAC 5, the Num Lock indicator on the 
    management station does not necessarily coincide with the state of the Num 
    Lock on the remote server. The state of the Num Lock is dependent on the 
    setting on the remote server when the remote session is connected, regardless 
    of the state of the Num Lock on the management station.
    Why do multiple Session Viewer windows appear when I establish a console 
    redirection session?
    You are configuring a console redirection session to the local system. 
    Reconfigure the session to a remote system.
    If I am running a console redirection session and a local user accesses the 
    remote system, do I receive a warning message?
    No. If a local user accesses the system, he/she can override your actions 
    without sending a warning. 
    How much bandwidth do I need to run a console redirection session?
    Dell recommends a 5 MB/sec connection for good performance. A 1 MB/sec 
    connection is required for minimal performance. 
    						
    							180Using GUI Console Redirection
    What are the minimum system requirements for my management station to 
    run console redirection?
    The management station requires an Intel Pentium III 500 MHz processor 
    with at least 256 MB of RAM.
    What are the maximum number of console redirection sessions that I can 
    run on a remote system?
    The DRAC 5 supports up to two simultaneous console redirection sessions.
    Why do I have mouse synchronization problems?
    On Linux (Red Hat or Novell) systems, there are known mouse arrow 
    synchronization issues. To minimize mouse synchronization problems, 
    ensure that all users use the default mouse settings.
    How can I install a Web browser on my management station that has a read-
    only file system?
    If you are running Linux and your management station has a read-only file 
    system, a browser can be installed on a client system without requiring a 
    connection to a DRAC 5. By using the native plug-in installation package, the 
    browser can be manually installed during the client setup phase. 
     CAUTION: In a read-only client environment, if the DRAC 5 firmware is updated to 
    a newer version of the plug-in, the installed virtual media plug-in becomes 
    inoperative. This is because earlier plug-in features are not allowed to function 
    when the firmware contains a newer plug-in version. In this case, you are 
    prompted for plug-in installation. Since the file system is read-only, the 
    installation fails and the plug-in features are not available.
    To obtain the plug-in installation package:
    1
    Log into an existing DRAC 5.
    2Change the URL in the browsers address bar, from:
    https:///cgi-bin/webcgi/main
    to:
    https:///plugins/ # Be sure to include the 
    trailing slash. 
    						
    All Dell manuals Comments (0)