40 OPERATION AND FUCTIONS MICOM Circuit Power Circuit DC Output Power (Voltage) Point Oscilloscope Measurement Remarks * DC output 15.7V 11.96V
41 OPERATION AND FUCTIONS SMPS Movement Wave Drain to Source Break Voltage Point Oscilloscope Measurement Remarks SMP SIC PIN 1,2 *Voltage between DRAIN and SOURCE : below 650V OVP(Overvoltage Protection) Wave at power input Point Oscilloscope Measurement Remarks SMPS IC PIN 3,4 *Minimum standard voltage OVP start : 23.2V at
42 OPERATION AND FUCTIONS Initial Power Wave of Switching Power IC Point Oscilloscope Measurement Remark SMPS IC PIN 3,4
43 OPERATION AND FUCTIONS Sensors Circuit Diagram Fnction of Each Sensor [ F-sensor ] 1) It senses the temperature of freezer compartment and controls Comp., F-fan ON / OFF. 2) How it works ; Working Point Low ON Mid OFF High OFF Working Temp. -11.0 -20.0 - 26.0 Resistance 14.74k 22.33k 30.92k Sensing Voltage 3.50 V 3.00 V 2.14 V [ D-sensor ] It senses return point of defrosting heater. Working Point Return point of defrosting heater Working Temp. 10 Resistance 19.53k Sensing Voltage 3.1 V [ R-sensor ] 1) It senses the temperature of refrigerator compartment and controls R-fan ON / OFF. 2) How it works ; Working Point Low ON Mid OFF High OFF Working Temp. 2.65 0.3 -1.7 Resistance 26.88k 29.34k 32.00k Sensing Voltage 2.90V 2.81V 2.74V C C C C C C C
44 OPERATION AND FUCTIONS 1) Cut J18 on M-PCB, then temp. is low e red -2 than [Mid OFF point]. 2) In addition to 1) action, cut J22 on M-PCB, then the temp. is low e red -1 more. Relay Function Circuit Diagram How it works ; ON Conditi on OFF Condition C ontrol Control Method MI CO M POR T IC 2 Output PIN MICOM POR T IC 03 Out put PIN COMP REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY #1 3.7V #10 0.7V #1 0V #10 12V R-LAMP #4 3.7V #11 0.7V #4 0V #11 12V DIS-LAMP #3 3.7V #12 0.7V #3 0V #12 12V DISP-SOL #5 3.7V #13 0.7V #5 0V #13 12V W A TER(ICE) #1 3.7V #10 0.7V #1 0V #10 12V W A TER(DIS) #4 3.7V #11 0.7V #4 0V #11 12V GEAR-M #3 3.7V #12 0.7V #3 0V #12 12V D-HTR #5 3.7V #13 0.7V #5 0V #13 12V F-LAMP #4 3.7V #11 0.7V #4 0V #11 12V CUBE-SOL #4 3.7V #11 0.7V #4 0V #11 12V W /S HTR #2 3.7V #14 0.7V #2 0V #14 12V C C * In case refrigeration of refrigerator compartment is poor or insufficient though comp. and R-fan operate in normal way ;
45 OPERATION AND FUCTIONS Fan Function How it works ; ON Condition OFF Condition MICOM Port MICOM Port Control Object Control Method 31 32 33 IC Collector 31 32 33 IC Collector Low (10V) operation 5V 0V 0V 10.35V 0V Mid (12V) operation 0V 5V 0V 12.19V 0V F-FAN High (14V) operation 0V 0V 0V 14.38V 5V 5V 5V 0V ON Condition OFF Condition MICOM PORT MICOM Port Control Object Control Method 39 40 41 IC Collector 39 40 41 IC Collector Low (10V) operation 0V 5V 5V 10.38V 0V Mid (12V) operation 5V 0V 5V 12.24V 0V R-FAN High (14V) operation 5V 5V 5V 14.42V 0V 0V 0V 0V ON Condition OFF Condition MICOM Port MICOM Port Control Object Control Method 37 38 IC Collector 37 38 IC Collector High (14V) operation 0V 0V 14.54V 0V C-FAN Low (10V) operation 5V 0V 10.45V 5V 5V 0V
46 OPERATION AND FUCTIONS Circuit Diagram of Main PCB