    							40
    OPERATION AND FUCTIONS
     MICOM Circuit 
     Power 
     Circuit 
     
     
     
      DC Output Power (Voltage)    
    Point Oscilloscope  Measurement Remarks 
     
     
     
     
      
    * DC output 
     
    15.7V 
    11.96V 
     
     
    						
    							41
    OPERATION AND FUCTIONS
      SMPS Movement Wave 
      Drain to Source Break Voltage 
    Point  Oscilloscope  Measurement  Remarks 
    SMP
    SIC 
    PIN 
    1,2 
       *Voltage between 
    DRAIN and 
    SOURCE :   
    below 650V 
     
      OVP(Overvoltage Protection) Wave at power input 
    Point 
    Oscilloscope  Measurement Remarks 
    SMPS 
    IC PIN 
    3,4 
     *Minimum 
    standard 
    voltage  
    OVP start :   
    23.2V 
    at
     
    						
    							42
    OPERATION AND FUCTIONS
      Initial Power Wave of Switching Power IC 
    Point 
    Oscilloscope Measurement Remark 
    SMPS 
    IC PIN 
    3,4 
      
     
    						
    							43
    OPERATION AND FUCTIONS
     Sensors 
     Circuit Diagram 
     
     
     Fnction of Each Sensor 
    [ F-sensor ] 
    1) It senses the temperature of freezer compartment and controls Comp., F-fan ON / OFF. 
    2) How it works ; 
    Working Point Low ON  Mid OFF  High OFF 
    Working Temp. -11.0   -20.0   - 26.0  
    Resistance  14.74k    22.33k    30.92k  
    Sensing Voltage  3.50 V   3.00 V   2.14 V 
     
    [ D-sensor ] 
      It senses return point of defrosting heater. 
    Working Point Return point of defrosting heater 
    Working Temp. 10  
    Resistance  19.53k   
    Sensing Voltage  3.1 V 
     
    [ R-sensor ] 
    1) It senses the temperature of refrigerator compartment and controls R-fan ON / OFF. 
    2) How it works ; 
    Working Point Low ON  Mid OFF  High OFF 
    Working Temp. 2.65   0.3   -1.7  
    Resistance  26.88k   29.34k   32.00k  
    Sensing Voltage  2.90V   2.81V   2.74V 
     C  C  C 
     C 
     C  C  C 
     
    						
    							44
    OPERATION AND FUCTIONS
    1) Cut J18 on M-PCB, then temp. is low e red -2   than [Mid OFF point]. 
    2) In addition to 1) action, cut J22 on M-PCB, then the temp. is low e red -1   more. 
     Relay  Function  
     Circuit  Diagram  
     
      How it works ; 
    ON Conditi on  OFF Condition 
    C ontrol   Control  
    Method MI CO M 
    POR T  IC 2 Output  
    PIN MICOM 
    POR T  IC 03 Out put  PIN 
    COMP  REPLAY 
    REPLAY 
    REPLAY 
    REPLAY 
    REPLAY 
    REPLAY 
    REPLAY 
    REPLAY 
    REPLAY  REPLAY  REPLAY #1 3.7V #10 0.7V #1 0V #10 12V 
    R-LAMP  
    #4 3.7V #11 0.7V #4 0V #11 12V 
    DIS-LAMP  
    #3 3.7V #12 0.7V #3 0V #12 12V 
    DISP-SOL  
    #5 3.7V #13 0.7V #5 0V #13 12V 
    W A TER(ICE)  
    #1 3.7V #10 0.7V #1 0V #10 12V 
    W A TER(DIS)  
    #4 3.7V #11 0.7V #4 0V #11 12V 
    GEAR-M   
    #3 3.7V #12 0.7V #3 0V #12 12V 
    D-HTR  
    #5 3.7V #13 0.7V #5 0V #13 12V 
    F-LAMP  
    #4 3.7V #11 0.7V #4 0V #11 12V 
    CUBE-SOL   
    #4 3.7V #11 0.7V #4 0V #11 12V 
    W /S HTR 
    #2 3.7V #14 0.7V #2 0V #14 12V 
     C 
     C 
    * In case refrigeration of refrigerator compartment is poor or insufficient though comp. and R-fan 
      operate in normal way ;
     
    						
    							45
    OPERATION AND FUCTIONS
     Fan Function
      How it works ; 
    ON Condition  OFF Condition 
    MICOM Port  MICOM Port Control 
    Object Control 
    Method 
    31 32 33 IC Collector 
    31 32 33 IC Collector 
    Low (10V) 
    operation 5V 0V 0V  10.35V  0V 
    Mid (12V) 
    operation 0V 5V 0V  12.19V  0V F-FAN 
    High (14V) 
    operation 0V 0V 0V  14.38V 5V 5V 5V 
    0V 
     
    ON Condition  OFF Condition 
    MICOM PORT  MICOM Port Control 
    Object Control 
    Method 
    39 40 41 IC Collector 
    39 40 41 IC Collector 
    Low  (10V) 
    operation 0V 5V 5V  10.38V  0V 
    Mid (12V) 
    operation 5V 0V 5V  12.24V  0V R-FAN 
    High (14V) 
    operation 5V 5V 5V  14.42V 0V 0V 0V 
    0V 
     
    ON Condition  OFF Condition 
    MICOM Port  MICOM Port Control 
    Object Control 
    Method 
    37 38 IC Collector 
    37 38 IC Collector 
    High (14V) 
    operation 0V 0V  14.54V  0V 
    C-FAN 
    Low (10V) 
    operation 5V 0V  10.45V 5V 5V 
    0V 
     
    						
    							46
    OPERATION AND FUCTIONS
      Circuit Diagram of Main PCB 
     
     
    						
    							47
    DIAGRAM
     < RSCR TYPE >
    WIRING DIAGRAM
     
    						
    							48
    DIAGRAM
     < CSR TYPE >
     
    						
    							49
    DIAGRAM
    CIRCUIT WIRING DIAGRAM
    Main PCB
     
    						
    All Daewoo manuals Comments (0)