    							30
    OPERATION AND FUCTIONS
     
    CONTENTS REMARKS 1. Conditions to turn on LCD Light 
       1) Power input (plugin) 
    2) When any button on the panel is pushed, first the back light turns on, then 
    button control is done. 
          3) When F/R door is open, the light turns on. 
     
      2. Conditions to turn off the light 
            1) The back light turns off 10 seconds after F/R door is closed   
    2) 1 minute after button control  
     
      Explanation After Delivery 
    INPUT Control Object 
    FREEZER SET. button 
    REFRIGERATOR SET. button 
    Power Cord Electrical components and LCD 
    CONTENTS REMARKS  
    1. Start 
          Push REFRIGERATOR SET. button for 3 seconds within 10 seconds just 
    after power input. 
     
    2. Control  
      1) Electrical components are OFF for 3 hours. 
      2) Display operates in normal way.  
     
      Prevention of Compressor Restart   
    INPUT Control Object 
    None Comp. CONTENTS REMARKS Comp. does not start again for 6 minutes though F-sensor is ON.  6min. delay 
     
      Back Up Function 
    INPUT Control Object 
    None  CONTENTS REMARKS  
    1. Filter Exchange Information : Record as a realtime from the point of Power 
    Input. 
    2.P FACTOR (Information about Ice Maker) 
     
    3.Ice Maker Lock 
      
     
    						
    							31
    OPERATION AND FUCTIONS
      Delay Function of Electric Components 
    INPUT Control Object 
    COMP ON/OFF COMP 
    F-FAN 
    CONTENTS REMARKS  
    1)  F-fan delay by comp. ON/OFF 
      F-fan is ON/OFF 1 minute after comp. is ON/OFF. 
     
      
    2) F an Delay  and Priority    
    R F A N
    ON   condition
    0. 5s ec .
    ON
    ON
    ON 1. 0s ec .
    1. 5s ec .
    F FA N
    C F A N
    OF F
    OF F
    OF F
      
    3) F / R-fan delay  by door  open/close for easy
     door opening. 
      Inspection : checkup door opening 2 hours after initial start. 
          F irst R is  ON, 1 second la ter F  is ON to  protect DC fan  against over cu rrent at 
    initial start.   
     
    D OOR
    R F AN
    OP E N
    CLO S E
    20.5 sec. (0.5sec.
    for first 2 hrs.)
    21sec. (1sec. for first 2 hrs.)
    ON
    OF F
    ON
    OF FF FA N
     
     
      
     
    1 min.1 min.
     
    						
    							32
    OPERATION AND FUCTIONS
      Home Bar (Refreshment Center) Heater  
    INPUT Control Object 
    None COMP CONTENTS REMARKS It is linked with comp.   
     
      Control of Interior Lights 
    INPUT Control Object 
    Refrigerator Door 
    Freezer Door 
    Home-Bar Door   
    (Refreshment Center) COMP 
    CONTENTS REMARKS 1) Control of Refrigerator Compartment Lights 
    R lights turn ON/OFF by R-door switch (ON/OFF). 
            10 minutes after sensing door open, the lights turn off automatically though 
    door close is not sensed.   
     
    2) Control of Freezer Compartment Lights 
    F lights turn ON/OFF by F-door switch (ON/OFF). 
        10 minutes after sensing door open, the lights turn off automatically though 
    door close is not sensed. 
     
     
    3) R-lights ON/OFF by Home-Bar door opening 
        R-lights turn ON for 1 minute after sensing HOME-BAR switch open. 
      (If the switch is pushed again within 1 minute, the light turns on another   
    1 minute.) 
     
    4) DISPENSER LAMP CONTROL 
       DISPENSER LAMP turns ON/OFF by DISPENSER SW.   
       Dispenser Lamp turns ON for 5 seconds after sensing switch close. 
      
     
     Demonstration Function 
    INPUT Control Object 
    LOCK button 
    REFRIGERATOR SET. button 
    SLEEP button COMP 
    F-FAN 
    R-FAN 
    CONTENTS REMARKS  
    1. Start   
          1) Set LOCK ON first. 
    2) Push SLEEP button 5 times while pushing REF SET. button simultaneously. 
     
    2. Control 
          1)    All other electrical components are OFF except for F-fan / R-fan.   
    2)  Fan Control 
        DOOR OPEN    FAN ON / DOOR CLOSE    FAN OFF 
       3) Display : Normal mode (3.8sec.)   SPEED(3sec.)  Silent mode(3sec.)   
    Sleep mode (3sec.) 
    3. Stop or Termination 
          1) During Demo mode push SLEEP button 5 times while pushing REF SET. 
    button simultaneously. 
       2) Power in again. 
        
     
    						
    							33
    OPERATION AND FUCTIONS
      Regulation of R-sensor OFF Point 
    INPUT Control Object 
    J18, 22 on Main PCB  Resistance of R-sensor Mid OFF Point CONTENTS REMARKS  
      Regulation of R-sensor OFF point (1.5degree DOWN) 
      In case refrigeration of refrigerator is weak or insufficient, take the following action. 
    R-SENSOR
    OP1- 1-2
    R26
    R70
    R71OP OP1-
    1-1
     
      R26 : R-SENSOR standard resistance in normal mode (31.4K ) 
          R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K) 
          R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K) 
      
      R26 = Mid OFF point 
      R26 + R70 = Mid OFF point - 1.5 deg 
      R26 + R70 + R71 = Mid OFF point - 3.0 deg  
     
      Summary of Function 
    CONTENTS REMARKS 
       
      How to start function modes 
      All the modes are started with LOCK ON except for explanation after delivery & installation. 
     
      A/S forced defrosting FREEZER SET. +    REFRIGERATOR SET. 5 
    times  
      Demonstration  REFRIGERATOR SET. +    SLEEP 5 times   
     Explanation after delivery & 
    installation REFRIGERATOR SET. for 3 sec. Right after 
    first power in  
      ERROR display  REFRIGERATOR SET. + LOCK 3 times   
     
    						
    							34
    OPERATION AND FUCTIONS
     
      Regulation of R-sensor OFF Point 
    INPUT Control Object 
    J18, 22 on Main PCB  Resistance of R-sensor Mid OFF Point CONTENTS REMARKS  
      Regulation of R-sensor OFF point (1.5degree DOWN) 
      In case refrigeration of refrigerator is weak or insufficient, take the following action. 
    R-SENSOR
    OP1-2
    R26
    R70
    R71OP OP1-
    1-1
     
      R26 : R-SENSOR standard resistance in normal mode (31.4K ) 
          R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K) 
          R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K) 
      
     R26 = Mid OFF point 
     R26 + R70 = Mid OFF point - 1.5 deg 
     R26 + R70 + R71 = Mid OFF point - 3.0 deg  
     
      Summary of Function 
    CONTENTS REMARKS 
       
      How to start function modes 
      All the modes are started with LOCK ON except for explanation after delivery & installation. 
     
      A/S forced defrosting FREEZER SET. +   REFRIGERATOR SET. 5 
    times  
      Demonstration  REFRIGERATOR SET. +    SLEEP 5 times   
     Explanation after delivery & 
    installation REFRIGERATOR SET. for 3 sec. Right after 
    first power in  
      ERROR display  REFRIGERATOR SET. + LOCK 3 times   
     
     
     
    						
    							35
    OPERATION AND FUCTIONS
     
    Input Control Object 
    Fully Ice Sensor 
    Ice Maker Lock Ice seperation Motor 
    CONTENTS REMARKS 
    1-1. Ice Maker FLOW 
     
    RETURN
    ICE Making
    ICE Drop
    Supply water into the Ice maker
    Check water input is normal.
     
     
     
    1)   By Pushing of Ice Maker ASSY TEST S/W (Over 1 Sec.):  
    TEST Mode Convert 
              (Ice Drop Mode Start with Test Mode Proceed) 
     
      2)  Ini
    tial Power inpu t 
    => Ic e Make r is  horizonta l => Proc eed 
    from Ice maker Mode 
     
      3)  Water-Input hose HTR Control 
        
        
        
     
      4) Water Input Ready State 
        
         
        
      5) Crusher Function 
        
          
    Normal operation -: ON
    Ice Marker Operation -: OFF
    Ice Marker Stop- : OFF
    Demo Mode -: OFF
    Condition : Full Sensing of Ice
    Operation : Processing to Ice Markder Mode during Ice Marker Flow( Ice Drop, Water Input 
    mode Stop)
    Stop: If Normal operation Proceed => Auto -Stop
    F-DOOR OPEN : Function stop
    F-DOOR CLOSE : Function Normal Start !
    @
    #
    $
    !
    @
    !
    @  
    #
    START
    ICE MAKER
    Mode
    ICE DROP
    Mode
    Water Input
    Mode
    Check
    Mode
    STOP the water input mode
     
    						
    							36
    OPERATION AND FUCTIONS
     
     
    CONTENTS REMARKS 
     
    1-2. Ice Maker M
    ODE 
     
    NO
    NO
    YES
    YES
    NO
    YESYES
    NO
     
     
    1)  
     
    2)  
     
    3)   I-Sensor Error: Ice Maker Complete after 4.8HR  
    I-S is -12.5    and below after 130 min.=> Ice maker complete
    Although I-S isnt -12.5    below for 130 min, I-S maintains -9.5    below continuously 
    => Ice maker comlpete
     
     
    2. Ice Drop MODE 
    status
    Ice tray
    level
    level
    normal
    level
    8-11 Max 1.1
    8.5-12.20.2
    10 11 
    1.1 
     1) Each Section’s Time used in S/W ERROR Confirm 
      2) Ice Drop MOTOR Rotation is Sensible by Each  Sections 
      3) S/W ERROR: Ice Drop Every Time 
      4) Ice Drop MOTOR ERROR: Stop to the Status  
     
      
    START
    130 min passed?
    I-S
    						
    							37
    OPERATION AND FUCTIONS
    CONTENTS REMARKS 
    3. Water-Input MODE 
    N
    Y
    Flow-Sensor Error mode             START
    Inlet value ON
    Water input pulse Count=0
    Y
    Y
    N
    N
    Y
    N
     
    1)  Convert of Water-Input Mode After Ice Drop: 
     Water-Input Valve Open. 
      2) Flow Sensor Error: Water-Input is Controlled by Time  
      3) Veriable Factor Value : Using for A/S  Steps 
         
          (Water input by Time -: Maximum Water Inut Time => 15 sec.
     
    4.
     
     
     
     RT-S 7  ~13 ~19 ~29 ~39 39  
    I-S -10 -9 -8 -7 -6 -5
     
    Flow Sensor Normal Operation : Flow Pulse Value sets 238
    Flow Sensor error : Water input time => 5.5 sec.
     C 
     C 
     C 
     C 
     C 
     C  C 
     C  C 
     C 
     C 
     C 
    !
    @
    Water-Input Confirm MODE
    I-S Temp. Rising Value with RT-S Temp. Mode after 5 min. : Estimate of Water Input
    1 Sec passed after inlet 
           value on?
    Water input pulse >10
    Water input pulse >target pulse
    time> target time
    Inlet value off
    STOP
     
    						
    							38
    OPERATION AND FUCTIONS
     Dispenser Control Function 
    Control Object 
    Dispenser SW 
    Water/Ice Button 
    Lock Ice Maker Button 
    Freezer Door SW Dispenser Lamp 
    Crusher Motor 
    Flat Solenoid 
    Crusher Solenoid 
    Dispenser Water Valve 
    Contents Remark  
     
     
    1) Water/Ice Selection Button 
     
        Progress : Water   Ice Cube   Crushed Ice   Water 
       
     
    2) Lock Ice Maker Button 
      Start by pushing Lock Ice Maker button 
       Lock Icer Maker is ON, 
        The Icon & Box of Cube Ice/Crushed Ice disappear,
               WaterIcon & Box is always  ON
              Stop by  pushing Lock Ice Maker button again.   
               Lock Icer Maker Icon is OFF , 
      T he Icon & Box ofCube Ice/Crushed Iceis OFF , 
      WaterIcon & Box is ON. 
     
    3) Display  
         - Initial Mode : Wateer ICON & Letter is ON.
         - A rectangle Line around the icon lights up to indicate your selection is on.
         - The Icon of water, Ice Cube, Crushed Ice is always  ON.( Exception, Dispenser 
           S/W Error)
         - When pushing  Lock Ice Maker:
           Lock Ice Maker LED is ON , The letters of crushed, cube Ice are OFF
         - There is no input during 1 hour, Dispeser transform into Water Mode.
     
    Input 
    * Initial Mode : Water
    * Pushing the dispenser value, water/Ice cube/crushed Ice is dispensed as your selection.
    !
    @
     
    						
    							OPERATION AND FUCTIONS
    Contents Remark 
     
    4) Control Flow & Timing Chart 
     
    4-1)Crushed Ice 
    D.P SW (In) D.P SW (In)
    Crusher Motor Crusher MotorD.P Lamp D.P Lamp
    D.P S/V (Out)D
    A
    A
    C
     
    4-2) Ice Cube  
    D.P SW (In) D.P SW (In)
          D.P S/V(Flap)       D.P S/V(Flap)    Cube S/V     Cube S/V
     Gear Motor
     Gear MotorD.P Lamp D.P Lamp
    A
    C
    A
    A
    B
    D
     
     
    4-3) Water 
    D.P Lamp D.P Lamp
    D.P SW (In)
    D.P SW (In)
    Water S/V Water S/VD
    A
     Delay Time : A = 500ms, B = 500ms, C = 2.0s D = 5.0s 
      