Daewoo Frs 2011i Service Manual
Have a look at the manual Daewoo Frs 2011i Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 51 Daewoo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
30 OPERATION AND FUCTIONS CONTENTS REMARKS 1. Conditions to turn on LCD Light 1) Power input (plugin) 2) When any button on the panel is pushed, first the back light turns on, then button control is done. 3) When F/R door is open, the light turns on. 2. Conditions to turn off the light 1) The back light turns off 10 seconds after F/R door is closed 2) 1 minute after button control Explanation After Delivery INPUT Control Object FREEZER SET. button REFRIGERATOR SET. button Power Cord Electrical components and LCD CONTENTS REMARKS 1. Start Push REFRIGERATOR SET. button for 3 seconds within 10 seconds just after power input. 2. Control 1) Electrical components are OFF for 3 hours. 2) Display operates in normal way. Prevention of Compressor Restart INPUT Control Object None Comp. CONTENTS REMARKS Comp. does not start again for 6 minutes though F-sensor is ON. 6min. delay Back Up Function INPUT Control Object None CONTENTS REMARKS 1. Filter Exchange Information : Record as a realtime from the point of Power Input. 2.P FACTOR (Information about Ice Maker) 3.Ice Maker Lock
31 OPERATION AND FUCTIONS Delay Function of Electric Components INPUT Control Object COMP ON/OFF COMP F-FAN CONTENTS REMARKS 1) F-fan delay by comp. ON/OFF F-fan is ON/OFF 1 minute after comp. is ON/OFF. 2) F an Delay and Priority R F A N ON condition 0. 5s ec . ON ON ON 1. 0s ec . 1. 5s ec . F FA N C F A N OF F OF F OF F 3) F / R-fan delay by door open/close for easy door opening. Inspection : checkup door opening 2 hours after initial start. F irst R is ON, 1 second la ter F is ON to protect DC fan against over cu rrent at initial start. D OOR R F AN OP E N CLO S E 20.5 sec. (0.5sec. for first 2 hrs.) 21sec. (1sec. for first 2 hrs.) ON OF F ON OF FF FA N 1 min.1 min.
32 OPERATION AND FUCTIONS Home Bar (Refreshment Center) Heater INPUT Control Object None COMP CONTENTS REMARKS It is linked with comp. Control of Interior Lights INPUT Control Object Refrigerator Door Freezer Door Home-Bar Door (Refreshment Center) COMP CONTENTS REMARKS 1) Control of Refrigerator Compartment Lights R lights turn ON/OFF by R-door switch (ON/OFF). 10 minutes after sensing door open, the lights turn off automatically though door close is not sensed. 2) Control of Freezer Compartment Lights F lights turn ON/OFF by F-door switch (ON/OFF). 10 minutes after sensing door open, the lights turn off automatically though door close is not sensed. 3) R-lights ON/OFF by Home-Bar door opening R-lights turn ON for 1 minute after sensing HOME-BAR switch open. (If the switch is pushed again within 1 minute, the light turns on another 1 minute.) 4) DISPENSER LAMP CONTROL DISPENSER LAMP turns ON/OFF by DISPENSER SW. Dispenser Lamp turns ON for 5 seconds after sensing switch close. Demonstration Function INPUT Control Object LOCK button REFRIGERATOR SET. button SLEEP button COMP F-FAN R-FAN CONTENTS REMARKS 1. Start 1) Set LOCK ON first. 2) Push SLEEP button 5 times while pushing REF SET. button simultaneously. 2. Control 1) All other electrical components are OFF except for F-fan / R-fan. 2) Fan Control DOOR OPEN FAN ON / DOOR CLOSE FAN OFF 3) Display : Normal mode (3.8sec.) SPEED(3sec.) Silent mode(3sec.) Sleep mode (3sec.) 3. Stop or Termination 1) During Demo mode push SLEEP button 5 times while pushing REF SET. button simultaneously. 2) Power in again.
33 OPERATION AND FUCTIONS Regulation of R-sensor OFF Point INPUT Control Object J18, 22 on Main PCB Resistance of R-sensor Mid OFF Point CONTENTS REMARKS Regulation of R-sensor OFF point (1.5degree DOWN) In case refrigeration of refrigerator is weak or insufficient, take the following action. R-SENSOR OP1- 1-2 R26 R70 R71OP OP1- 1-1 R26 : R-SENSOR standard resistance in normal mode (31.4K ) R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K) R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K) R26 = Mid OFF point R26 + R70 = Mid OFF point - 1.5 deg R26 + R70 + R71 = Mid OFF point - 3.0 deg Summary of Function CONTENTS REMARKS How to start function modes All the modes are started with LOCK ON except for explanation after delivery & installation. A/S forced defrosting FREEZER SET. + REFRIGERATOR SET. 5 times Demonstration REFRIGERATOR SET. + SLEEP 5 times Explanation after delivery & installation REFRIGERATOR SET. for 3 sec. Right after first power in ERROR display REFRIGERATOR SET. + LOCK 3 times
34 OPERATION AND FUCTIONS Regulation of R-sensor OFF Point INPUT Control Object J18, 22 on Main PCB Resistance of R-sensor Mid OFF Point CONTENTS REMARKS Regulation of R-sensor OFF point (1.5degree DOWN) In case refrigeration of refrigerator is weak or insufficient, take the following action. R-SENSOR OP1-2 R26 R70 R71OP OP1- 1-1 R26 : R-SENSOR standard resistance in normal mode (31.4K ) R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K) R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K) R26 = Mid OFF point R26 + R70 = Mid OFF point - 1.5 deg R26 + R70 + R71 = Mid OFF point - 3.0 deg Summary of Function CONTENTS REMARKS How to start function modes All the modes are started with LOCK ON except for explanation after delivery & installation. A/S forced defrosting FREEZER SET. + REFRIGERATOR SET. 5 times Demonstration REFRIGERATOR SET. + SLEEP 5 times Explanation after delivery & installation REFRIGERATOR SET. for 3 sec. Right after first power in ERROR display REFRIGERATOR SET. + LOCK 3 times
35 OPERATION AND FUCTIONS Input Control Object Fully Ice Sensor Ice Maker Lock Ice seperation Motor CONTENTS REMARKS 1-1. Ice Maker FLOW RETURN ICE Making ICE Drop Supply water into the Ice maker Check water input is normal. 1) By Pushing of Ice Maker ASSY TEST S/W (Over 1 Sec.): TEST Mode Convert (Ice Drop Mode Start with Test Mode Proceed) 2) Ini tial Power inpu t => Ic e Make r is horizonta l => Proc eed from Ice maker Mode 3) Water-Input hose HTR Control 4) Water Input Ready State 5) Crusher Function Normal operation -: ON Ice Marker Operation -: OFF Ice Marker Stop- : OFF Demo Mode -: OFF Condition : Full Sensing of Ice Operation : Processing to Ice Markder Mode during Ice Marker Flow( Ice Drop, Water Input mode Stop) Stop: If Normal operation Proceed => Auto -Stop F-DOOR OPEN : Function stop F-DOOR CLOSE : Function Normal Start ! @ # $ ! @ ! @ # START ICE MAKER Mode ICE DROP Mode Water Input Mode Check Mode STOP the water input mode
36 OPERATION AND FUCTIONS CONTENTS REMARKS 1-2. Ice Maker M ODE NO NO YES YES NO YESYES NO 1) 2) 3) I-Sensor Error: Ice Maker Complete after 4.8HR I-S is -12.5 and below after 130 min.=> Ice maker complete Although I-S isnt -12.5 below for 130 min, I-S maintains -9.5 below continuously => Ice maker comlpete 2. Ice Drop MODE status Ice tray level level normal level 8-11 Max 1.1 8.5-12.20.2 10 11 1.1 1) Each Section’s Time used in S/W ERROR Confirm 2) Ice Drop MOTOR Rotation is Sensible by Each Sections 3) S/W ERROR: Ice Drop Every Time 4) Ice Drop MOTOR ERROR: Stop to the Status START 130 min passed? I-S
37 OPERATION AND FUCTIONS CONTENTS REMARKS 3. Water-Input MODE N Y Flow-Sensor Error mode START Inlet value ON Water input pulse Count=0 Y Y N N Y N 1) Convert of Water-Input Mode After Ice Drop: Water-Input Valve Open. 2) Flow Sensor Error: Water-Input is Controlled by Time 3) Veriable Factor Value : Using for A/S Steps (Water input by Time -: Maximum Water Inut Time => 15 sec. 4. RT-S 7 ~13 ~19 ~29 ~39 39 I-S -10 -9 -8 -7 -6 -5 Flow Sensor Normal Operation : Flow Pulse Value sets 238 Flow Sensor error : Water input time => 5.5 sec. C C C C C C C C C C C C ! @ Water-Input Confirm MODE I-S Temp. Rising Value with RT-S Temp. Mode after 5 min. : Estimate of Water Input 1 Sec passed after inlet value on? Water input pulse >10 Water input pulse >target pulse time> target time Inlet value off STOP
38 OPERATION AND FUCTIONS Dispenser Control Function Control Object Dispenser SW Water/Ice Button Lock Ice Maker Button Freezer Door SW Dispenser Lamp Crusher Motor Flat Solenoid Crusher Solenoid Dispenser Water Valve Contents Remark 1) Water/Ice Selection Button Progress : Water Ice Cube Crushed Ice Water 2) Lock Ice Maker Button Start by pushing Lock Ice Maker button Lock Icer Maker is ON, The Icon & Box of Cube Ice/Crushed Ice disappear, WaterIcon & Box is always ON Stop by pushing Lock Ice Maker button again. Lock Icer Maker Icon is OFF , T he Icon & Box ofCube Ice/Crushed Iceis OFF , WaterIcon & Box is ON. 3) Display - Initial Mode : Wateer ICON & Letter is ON. - A rectangle Line around the icon lights up to indicate your selection is on. - The Icon of water, Ice Cube, Crushed Ice is always ON.( Exception, Dispenser S/W Error) - When pushing Lock Ice Maker: Lock Ice Maker LED is ON , The letters of crushed, cube Ice are OFF - There is no input during 1 hour, Dispeser transform into Water Mode. Input * Initial Mode : Water * Pushing the dispenser value, water/Ice cube/crushed Ice is dispensed as your selection. ! @
OPERATION AND FUCTIONS Contents Remark 4) Control Flow & Timing Chart 4-1)Crushed Ice D.P SW (In) D.P SW (In) Crusher Motor Crusher MotorD.P Lamp D.P Lamp D.P S/V (Out)D A A C 4-2) Ice Cube D.P SW (In) D.P SW (In) D.P S/V(Flap) D.P S/V(Flap) Cube S/V Cube S/V Gear Motor Gear MotorD.P Lamp D.P Lamp A C A A B D 4-3) Water D.P Lamp D.P Lamp D.P SW (In) D.P SW (In) Water S/V Water S/VD A Delay Time : A = 500ms, B = 500ms, C = 2.0s D = 5.0s 39