10 EXTERNAL VIEWS 2- 3. POWER CORD NO SHAPE OF POWER CORD PART CODE DESCRIPTION REMARK 1 3011315000 CP-2PIN For european country 2 401RA17200 CP-2PIN For other country 3 4006D17101 KP-30 For America & El Salvador 4 401PD17101 KP-211 For Japan & Taiwan 5 3011300801 BP-3PIN 6 3011303010 # 267 For Chile 7 3011315310 For Israel 8 3011303050 BS-1363AFor U.K, Middle Asia Singapore & Malaysia 9 3011301200 KP-551/550 For China & Australia Upper power cords part code is only lead wire, without any kinds of terminal or houisng
11 EXTERNAL VIEWS 2-4 DOOR COLOR CODE 1) ASSEMBLY URETHAN FREEZER DOOR FRS-2011 / FRS-20 31 (100V ~ 127V) Blowing AgentCyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000028060 3000028070 3000028050 3000028080 3000028040 FRS-2011 / FRS-2031 (220V/60Hz) Blowing AgentCyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000028460 3000028410 3000028010 3000028420 3000028000 FRS-2011 / FRS-2031 (220V~240V/50Hz) Blowing AgentCyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000028430 3000028440 3000028030 3000028450 3000028020 2) ASSEMBLY URETHAN REFRIGERATOR DOOR FRS-2031 Blowing AgentCyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000018830 3000018820 3000018810 3000018840 3000018800 FRS-2011 (100V ~ 127V) Blowing AgentCyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000025380 3000025370 3000025360 3000025390 3000025350 FRS-2011 (200V~240V) Blowing AgentCyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000025330 3000025320 3000025310 3000025340 3000025300 PART CODE COLOR TYPE PART CODE COLOR CODE COLOR TYPE COLOR TYPE COLOR CODE PART CODE COLOR TYPE COLOR CODE PART CODE COLOR CODE PART CODE COLOR TYPE COLOR CODE PART CODE COLOR TYPE COLOR CODE
12 OPERATION AND FUCTIONS INPUT Control Object Front PCB buttons FREEZER SET. button REFRIGERATOR SET. button SUPER FREEZER. button SUPER REFRIGERATOR. button WATER / ICE button LOCK Button / SLEEP button LCD CONTENTS REMARKS 1. Normal Operation 1) Temperature control of Freezer / Refrigerator ( Initial mode : Freezer & Refrigerator Middle ) 2) Lock mode / Sleep mode / Ice maker Lock : OFF 3) SPEED icon : inactive 4) FUZZY & DEODORIZER letters and icons : always ON 5) Water / Cube Ice / Crushed Ice ( Initial mode : Water ) 6) Other display modes Normal Operation Silent Mode CUSTOM LCD Normal Mode Load Mode Silence Mode Sleep Mode Freezer / Refrigerator BAR DIAL DIAL Temp. SEG. DIAL DIAL 1) Letters of [FRZ., REF., LOW, HIGH, SETTEMP ,FUZZY, DEODO., SILENT, SLEEP, Water] 2) Icons of [FUZZY, DEODO., SLEEP, Water] 3) Temp. bars and lines ON ON SILENT icon OFF OFF ON ON ON ON ON OFF SPEED letters OFF ON ON OFF OFF SPEED bars OFF ON (progressive) ON (progressive) OFF OFF LOCK ON/OFF, SLEEP ON/OFF DIAL DIAL Water / Cube Ice / Crushed Ice DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL DIAL 1. DISPLAY
13 OPERATION AND FUCTIONS CONTENTS REMARK 2. FREEZER SET. button Temperature control of Freezer compartment 5 steps of sequential temperature mode Initial mode by power input : MID (Temperature and bars are shown.) * Letters are not indicated at Soft-Mid and Mid-Strong modes. (Just Setting temperatures and bars are shown.) Temperature progress : Low (Low-Mid) Mid (Mid-High) HIgh Temp. indication : -15 C -17 -19 -21 -25 Number of bars : 5EA 3EA 5EA 3EA 5EA 3. SUPER FREEZER. button When this mode is chosen, QUICK icon and letters of freezer flicker 3 times and ON. (The set temperature and bars are still the previous value.) 4. REFREGERATOR SET. button Temperature control of Refrigerator compartment 5 steps of sequential temperature mode Initial mode by power input : MID (Temperature and bars are shown.) Letters are not indicated at Soft-Mid and Mid-Strong modes. (Just temperatures and bars are shown.) Temperature progress : Low (Low-Mid) Mid (Mid-High) HIgh Temp. indication : 4 3 2 1 0 Number of bars : 5EA 3EA 5EA 3EA 5EA 5. SUPER REFRIGERATOR. button When this mode is chosen, QUICK icon and letters of refrigerator flicker 3 times and ON. (The set temperature and bars are still the previous value.) 6. SLEEP button Start by pushing the button (ON lights.) Stop by pushing button again (OFF lights.) Automaticcally terminated after maximum 12 hours (OFF lights.) 7. Water/Ice button Select Water mode or Ice mode. A rectangle Line around the icon lights up to indicate your selection is on. Initial mode by power input: Watermode. Progress: Water Cube Ice Crushed Ice Water 8. LOCK button Start by pushing the button (LOCK letters and icon light.) * No other buttons and modes, buzzer sound are controllable. Stop by pushing button again for a second (OFF and icon light.) * Except Lockbutton, other buttons are inactive during Sleepmode. C C C C C C C C C ! @ ! @ ! @ ! @ ! @ #
14 OPERATION AND FUCTIONS CONTENTS REMARK 9. Lock Ice Maker button Start by pushing Lock Ice Makerbutton Lock Icer Makeris ON, The Icon & Box of Cube Ice/Crushed Icedisappear, WaterIcon & Box is always ON Stop by pushing Lock Ice Makerbutton again. Lock Icer Maker Icon is OFF , The Icon & Box of Cube Ice/Crushed Iceis OFF, WaterIcon & Box is ON. 10. Filter information The normal(Green LED) is on for 6 month after first power input. After six month, Red LED is on. How to reset Filter information. Push LOCK button and push the Lock Ice Maker button for 3 seconds. ! ! @ @ #
15 OPERATION AND FUCTIONS INPUT Control Object 1. FREEZER SET. button 2. SUPER FREEZER. button 3. F-sensor 1. COMP 2. F-FAN CONTENTS REMARKS 1. Temperature modes change by pushing the button. 2. Comp. and F-fan are controlled by ON / OFF point of each mode. 3. FC [ON / OFF] DIFF : 2 ( Freezer middle OFF point : -20.0 ) ( If RT† 13 , F-S OFF point is 2 UP. Freezer Middle OFF point : -18 ) 4. FC [Low (Low-Mid) Mid (Mid-High)] DIFF : 2 degrees respectively ( * [(Mid-HIgh) High] DIFF : 4 degrees ) 5. Control point of each mode Temp. MODE ON poi nt OFF poi nt Low MidHigh STEP DIFF STEP DIFF ON/ OFF DIFF -15.0 -20.0 -21.0 -26.0 -11.0 -16.0 -22.0 -18.0 -13.0 -20.0 (Low-Mid) (Mid-High) Low Low-Mid Mid Mid-High High C C C C C
16 OPERATION AND FUCTIONS CONTENTS REMARKS 6. SUPER FREEZER. (Quick Freezing) 1) Comp. and F-fan are ON (about 150 minutes) regardless of F-sensor. 2) F-fan runs at 14V for the first 90 min., then at 12V for the rest time. F/S F Fan SUPER FRZ. start F-fan RPM change pointNormal operation 90min. 14V 12V 60min. * ON/OFF DIFF. : fixed by MICOM * STEP DIFF. : fixed by MICOM * Comp. and C-fan : linked Te mperature Control of Refrigerator Compartment (RC) INPUT Control Object 1. REFRIGERATOR SET. button 2. R-sensor 1. COMP 2. R-FAN CONTENTS REMARKS 1. Temperature modes change by pushing the button. 2. R-fan are controlled by ON / OFF point of each mode. 3. RC [ON / OFF] DIFF : 0.5 ( RC middle OFF point : 0.7 ) ( If RT≤13 , R-S OFF point is 2 UP. Refrigerator Middle OFF point : 2.7 ) 4. RC [Low (Low-Mid) Mid(Mid-High)] DIFF : 1 degree respectively 5. Prevention of weak/poor-refrigeration 1) When weak refrigeration is sensed, comp. is ON regardless of F-sensor. 2) When R-sensor reaches R-fan OFF point, comp. is controlled by F-sensor and R-fan turns OFF. 3) Sensing point of weak refrigeration : R-sensor OFF point of each mode + 7 4) Termination point : Same as R-sensor OFF point of each mode * ON/OFF Diff. : fixed by MICOM * STEP DIFF. : fixed by MICOM Low Low-Mid Mid Mid-High High C C C C C C
17 OPERATION AND FUCTIONS CONTENTS REMARKS 6. Control point of each mode Temp MODE ON point OFF point LowMidHigh STEP DIFF STEP DIFF ON/OFF DIFF (0.35 deg)0.65 2.65 2.3-1.35 -1.7 Weak refrigeration point (Off point+7 )7.3 1.65 -0.35 -0.7 1.3 (Low-Mid) (Mid-High)0.3 6.35.3 8.39.3 7. Super refrigeration proceeds for 40 minutes. Example of temperature change (Refrigerator ; Low (normal) -> Super refrigeration ) 1) R-fan and comp. are ON until R-sensor reaches to over-refrigeration OFF point (-7 ). 2) After reaching to the point, it goes on with HIGH mode u ntil the end of Super refrigeration. It returns to normal after Quick refrigeration of 40 minutes. C C C C C C C C C C C C C C C * C
18 OPERATION AND FUCTIONS INPUT Control Object 1. SLEEP button 1. COMP 2. R-FAN 3. F-FAN 4. CUSTOM-LCD CONTENTS REMARKS 1. This mode starts with a push of SLEEP button. 2. Conditions to start Sleep mode F-sensor ≤ -13 Unless it is a restart within 40 minutes after the end of previous Sleep mode F-sensor error Door switch error Defrosting (Heater defrosting, pause, Fan delay) If the above conditions of ~ are all satisfied, the sleep mode starts. 3. Control of electrical parts 1) Mode 1 Once Sleep mode starts, all the electrical parts (COMP, F-FAN, R-FAN) turn OFF. (ON letters of SLEEP on LCD is display.) 2) Mode 2 It operates with Silent mode and ON le tters of SLEEP on LCD is displayed on.) 4. Termination of Sleep mode 1) MODE 1 F-sensor ≥ -9 In case of F-sensor error When other button is pushed during this mode Total F/R door open time exceeds 30 seconds during the mode If Sleep mode is terminated by , @ and , F/R-fan delay for 5 minutes and restart of this mode is prevented for 40minutes. It it exceeds time limit of 130 minute, Mode1 is terminated and Mode2 starts. 2) MODE 2 Sleep mode is terminated 12 hours after the first start. ( Speed mode and defrosting operate in normal way.) 5. After Sleep mode stops all the electrical parts return to normal operation and Sleep icon changes from ON to OFF. 6. If Sleep mode starts during PRECOOL, it goes on again after the Sleep mode is terminated. 7. If Sleep mode starts during Super FRZ., Super REF., it returns to previous set modeafter the Sleep mode is terminated. C C ! @ ! ! % # $ % ^ ! @ # $ % ^^
19 OPERATION AND FUCTIONS SILENT (Silence Mode) INPUT Control Object 1. CDS SENSOR 5. COMP 6. R-FAN 7. F-FAN 8. CUSTOM-LCD CONTENTS REMARKS 1. Purpose of Silence mode To reduce refrigerator noise at night by decresing fan RPM to a minimum degree 2. Condition to start 1) The optical or light sensor in top middle of control panel senses surround light and Silence mode starts if the amount of light sensed is below the standard value for more than 1 minute. (The mode does not start for initial 240 minutes to prevent down of cooling performance.) Standard value to decide night : below 5 ~7 Lux (optical sensor surface) Standard value to decide daytime : above 4~16 Lux (optical sensor surface) 3. Control Method Control Mode F-FAN R-FAN C-FAN Normal 10V 10V 10V Silence Load Control 12V 12V 10V 4. Termination Condition The mode stops if lux value is above the standard for more than 1 minute. Control of Each Mode INPUT Control Object 1. CDS SENSOR 2. R SENSOR 3. F SENSOR 1. F-FAN (14V, 12V, 10V) CONTENTS REMARKS Control of Silence mode : operation mode when the optical sensor feels that it is night Normal control : daytime operation mode (Refrigerator noise is relatively low at daytime.) Load control : operation mode when inside temperature goes up due to an increase of load (foods) or frequent door openings ! @