     Chapter 2: Installation 
    GE-DSH-73/DSH-82 and DSH-82-PoE User Manual  17 
    The top panel of the GE-DSH-73 Managed Industrial Switch has two terminal block 
    connectors: 
    •  Power connector - consists of two DC  power inputs and one fault alarm. 
    •  DI/DO connector - comprises two digital inputs-DI0 and DI1and two digita\
    l 
    outputs-DO0 and DO1. 
    Figure 2-9 :  Top Panel of GE-DSH-73  
     
     
     
     
     
     
     
     
     
      
    						
    							
    Chapter 2: Installation 
    18  GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 
    LED Indicators 
    The diagnostic LEDs that provide real-time information of system and optional status 
    are located on the front panel of the GE-DSH  series. The following table provides the 
    description of the LED status  and their meanings for the Managed Industrial Switch.  
     
    GE-DSH-82 LED Indicators 
    •  System 
     
    LED Color Status Meaning 
    On  The switch unit is power on. PWR  Green 
    Off No power. 
    On  The industrial switch is the master of X-Ring group. 
    R.M. Green 
    Off The industrial switch is not a ring master in X-Ring 
    group. 
    On  Power 1 is active. PWR1 
    Green 
    Off  Power 1 is inactive. 
    On  Power 2 is active. PWR2 Green 
    Off  Power 2 is inactive. 
    On  Power or port failure. FAULT Red  Off No failure. 
     
    • 10/100Base-TX Ports –  Port-1 to Port-8 
     
    LED Color Status Meaning 
    On  A network device is detected. 
    Blinking  The port is transmitting or receiving packets from the 
    TX device. Green 
    Off  No device attached. 
    On  The port is operating in full-duplex mode. 
    Blinking  Collision of Packets occurs. 
    Port-1 ~ Port-8 
    Amber 
    Off  The port is in half-duplex mode or no device is 
    attached. 
     
      
    						
    							
     Chapter 2: Installation 
    GE-DSH-73/DSH-82 and DSH-82-PoE User Manual  19 
     
    •  10/100Base-TX Ports –  Port-9, Port-10 
     
    LED Color Status Meaning 
    On  A network device is detected. 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Green 
    (Upper LED)  Off  No device attached 
    On 1000M 
    Port 9, Port 10 (RJ-45) 
    Green 
    (Lower LED)  
    Off 10/100M 
    On  The SFP port is linking 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Link/Active (P9, 
    P10 SFP)  Green 
    Off  No device attached 
     
    GE-DSH-73 LED Indicators 
    • System 
     
    LED Color Status Meaning 
    On  The switch unit is power on. PWR  Green 
    Off No power. 
    On  The industrial switch is the master of X-Ring group. 
    R.M. Green 
    Off The industrial switch is not a ring master in X-Ring 
    group. 
    On  Power 1 is active. PWR1 
    Green 
    Off  Power 1 is inactive. 
    On  Power 2 is active. PWR2  Green 
    Off  Power 2 is inactive. 
    On  Power or port failure. FAULT  Red 
    Off No failure. 
     
     
     
      
    						
    							
    Chapter 2: Installation 
    20  GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 
     
    • 10/100Base-TX Ports – Po rt-1 to Port-8  
     
    LED Color Status Meaning 
    On  A network device is detected. 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Green 
    Off  No device attached. 
    On  The port is operating in full-duplex mode. 
    Blinking  Collision of Packets occurs. 
    Port-1 ~ 6 & Port-8 
    Amber 
    Off The port is in half-duplex mode or no device is 
    attached. 
     
    • 
    10/100Base-TX Ports – Port-7 , Port-9 and Port-10  
     
    LED Color Status Meaning 
    On  A network device is detected. 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Green 
    (Upper LED)  Off  No device attached 
    On 1000M 
    Port 7, Port 9, 
    Port 10 (RJ-45) 
    Green 
    (Lower LED)  
    Off 10/100M 
    On  The SFP port is linking 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. 
    Link/Active 
    (P7, P9, P10  SFP)  Green 
    Off  No device attached 
      
    						
    							
     Chapter 2: Installation 
    GE-DSH-73/DSH-82 and DSH-82-PoE User Manual  21 
    GE-DSH-82-PoE LED Indicators 
    •  System 
     
    LED Color Status Meaning 
    On  The switch unit is power on. PWR  Green 
    Off No power. 
    On  The industrial switch is the master of X-Ring group. 
    R.M. Green 
    Off The industrial switch is not a ring master in X-Ring 
    group. 
    On  Power 1 is active. PWR1 
    Green 
    Off  Power 1 is inactive. 
    On  Power 2 is active. PWR2  Green 
    Off  Power 2 is inactive. 
    On  Power or port failure. FAULT  Red 
    Off No failure. 
     
    • 10/100Base-TX Ports – Po rt-1 to Port-8  
     
    LED Color Status Meaning 
    On  A network device is detected. 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Green 
    Off  No device attached. 
    On  The port is operating in full-duplex mode. 
    Blinking  Collision of Packets occurs. 
    Port-1 ~ Port-8 
    Amber 
    Off The port is in half-duplex mode or no device is 
    attached. 
      
    						
    							
    Chapter 2: Installation 
    22  GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 
    • PoE port link – Port-1 to Port-8 
     
    LED Color Status Meaning 
    On  An IEEE 802.3af PoE power device is detected. FWD 
    (P1 to P8)  Green 
    Off  No IEEE 802.3af PoE power device attached 
     
    • 10/100/1000Base-T / SFP combo in terface - Port-9, Port-10 
     
    LED Color Status Meaning 
    On  A network device is detected. 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Green 
    (Upper LED)  Off  No device attached 
    On 1000M 
    Port 9, Port 10 (RJ-45) 
    Green 
    (Lower LED)  
    Off 10/100M 
    On  The SFP port is linking 
    Blinking  The port is transmitting or receiving packets from 
    the TX device. Link/Active (P9, 
    P10 SFP)  Green 
    Off  No device attached 
      
    						
    							
     Chapter 2: Installation 
    GE-DSH-73/DSH-82 and DSH-82-PoE User Manual  23 
    Installing the Switch 
    This section describes how to install yo ur Managed Industrial Switch and make 
    connections to the Managed Industrial Switch. Please read the following topics and 
    perform the procedures in the order being  presented. To install your switch on a 
    desktop or shelf, simply co mplete the following steps. 
    In this paragraph, we will describe how to install the 8 10/100TX w/ X-Ring Managed 
    Industrial Switch and the installation points attended to it. 
    Installation Steps 
    1. Unpack the Industrial switch 
    2. Check if the DIN-Rail is screwed on the Indu strial switch or not. If the DIN-Rail is not 
    screwed on the Industrial switch, please  refer to DIN-Rail Mounting section for DIN-
    Rail installation. If users want to wall mount  the Industrial switch, please refer to Wall 
    Mount Plate Mounting section for  wall mount plate installation. 
    3. To hang the Industrial switch on the DIN-Rail track or wall. 
    4. Power on the Industrial switch. Refer to  the Wiring the Power Inputs section for 
    knowing the information about how to wi re the power. The power LED on the 
    Industrial switch will light up. Please refer  to the LED Indicators section for indication 
    of LED lights. 
    5. Prepare the twisted-pair, straight  through Category 5 cable for Ethernet 
    connection. 
    6. Insert one side of RJ-45 cable (category 5)  into the Industrial switch Ethernet port 
    (RJ-45 port) and another side of RJ-45 cabl e (category 5) to the network devices 
    Ethernet port (RJ-45 port), ex: Switch PC  or Server. The UTP port (RJ-45) LED on the 
    Industrial switch will light up when the  cable is connected with the network device. 
    Please refer to the LED Indicators  section for LED light indication. 
    NOTE:  Make sure that the connected network de vices support MDI/MDI-X. If it does 
    not support, use the crossover category-5 cable. 
    7. When all connections are set and LED lights  all show in normal, the installation is 
    complete. 
      
    						
    							
    Chapter 2: Installation 
    24  GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 
    DIN-Rail Mounting 
    The DIN-Rail is screwed on the Industrial Switch when out of factory. If the DIN-Rail is 
    not screwed on the Industrial Switch, plea se see the following pictures to screw the 
    DIN-Rail on the Switch. Follow the steps  below to hang the Industrial Switch. 
    Figure 2-10:  Rear Panel - DIN-Rail Kit 
     
    1. Insert the top of DIN-Rail into the track. 
    Figure 2-11 :  Rear Panel - DIN-Rail Kit 
      
    						
    							
     Chapter 2: Installation 
    GE-DSH-73/DSH-82 and DSH-82-PoE User Manual  25 
    2. Lightly push the DIN-Rail into the track. 
    Figure 2-12 :  DIN-Rail mounting 
     
    3. Check if the DIN-Rail is ti ghtened on the track or not. 
    4. To remove the industrial switch  from the track, reverse above steps. 
     
    Wall Mount Plate Mounting 
    Follow the steps below to mount the Indu strial Switch with wall mount plate. 
    1. Remove the DIN-Rail from the Industrial  Switch; loose the screws to remove the 
    DIN-Rail. 
    2. Place the wall mount plate on the re ar panel of the Industrial Switch. 
    3. Use the screws to screw the wall mo unt plate on the Industrial Switch.  
    4. Use the hook holes at the corners of th e wall mount plate to hang the Industrial 
    Switch on the wall. 
    5. To remove the wall mount plate, reverse the above steps. 
      
    						
    							
    Chapter 2: Installation 
    26  GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 
    Figure 2-13:  Wall mounting 
     
    Wiring the Power Inputs 
    The 6-contact terminal block connector on  the top panel of GE-DSH-82-PoE is used 
    for two DC redundant power inputs.  
    NOTE:  This product is intended to be supplied  by a UL Listed Direct Plug-In Power Unit 
    marked Class 2 or LPS and output rated 48 VDC, 380 mA minimum. 
    Please follow the steps below to insert the power wire. 
    1. Insert the positive / negative DC power  wires into the contacts 1 and 2 for POWER 
    2, or 5 and 6 for POWER 1.  
    						