Page 31
J Series Serial Commands Technical Reference Information31 of 90020-100796-01 Rev. 1 (10-2011) (DEF) DEFAULTS CONTROL GROUP: Unsaved SUBCLASS: Power Down ACCESS LEVEL: Admin DESCRIPTION This control will reset all preference and configuration settings in the device to their default values. The value of 111 must be sent. This helps prevent accidental use of this control. SUBCODE DESCRIPTION OF USE Restore all factory defaults. EXAMPLES: (DEF 111) - Restore all preferences, configurations,...
Page 32
32 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (DMX) DMX/Artnetcon’t SUBCODE DESCRIPTION OF USE Selects the source of the DMX/ArtNet input: 0 = DMX Input Card and ArtNet - Monitors for data on both the DMX input card (if plugged in) and ArtNet. If the DMX card is actively receiving data, ArtNet will be ignored. 1 = DMX Input Card Only - Only monitors the DMX card for input 2 = ArtNet Only - Only monitors ArtNet for input 3 = Disabled - Both...
Page 33
J Series Serial Commands Technical Reference Information33 of 90020-100796-01 Rev. 1 (10-2011) (DMX) DMX/ArtNet con’t EXAMPLES: (DMX1) Ignore ArtNet traffic, use only the DMX interface (DMX+CHAN 50) set the base channel to 50 (i.e. listen to data starting at channel 50) (DRK) 3D DARK INTERVAL CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Controls the time between frames when no image is being projected to the screen. Used for 3D applications to determine the...
Page 34
34 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (DTO) DETAIL OVERSHOOT CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Detail overshoot / undershoot control is provided to minimize ringing on the enhanced edges detail and texture effects. SUBCODE INxy DESCRIPTION OF USE Set the detail overshoot for slot x, input y. MAIN Set the detail overshoot for main video. PIIP or SECD Set the detail overshoot for PIP or...
Page 35
J Series Serial Commands Technical Reference Information35 of 90020-100796-01 Rev. 1 (10-2011) (EBB) Blacklevel Blending con’t RHTV Changes edge blending black level in the right zone. BTMV Changes edge blending black level in the bottom zone. TLTV Changes edge blending black level in the top-left zone. TRTV Changes edge blending black level in the top-right zone. BLTV Changes edge blending black level in the bottom-left zone. BRTV Changes edge blending black level in the bottom-right zone. LFTW...
Page 36
36 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (EBL) Edge Blending con’t TOPS Changes edge blending curve slope at the midpoint on the top edge. BTMW Changes edge blending width of the bottom edge. BTMM Changes edge blending curve midpoint of the bottom edge. BTMS Changes edge blending curve slope at the midpoint on the bottom edge. STDC Enable the advanced curve settings. OVLP Enables or Disables edge blending overlap control. This more will make the...
Page 37
J Series Serial Commands Technical Reference Information37 of 90020-100796-01 Rev. 1 (10-2011) (EME) Error Message Enable con’t EXAMPLES: (EME ?) Get current Error Message Enable state. (EME 1) Direct error messages to the screen. (ESC) EDIT SECONDARY CHANNEL SETTING CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION In Interleaved 3D mode, this control allows the user the option to independently control primary and secondary channel settings, or to use the...
Page 38
38 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (FCS) FOCUS LENS POSITION ADJUSTMENT CONTROL GROUP: Configuration SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Move the focus motor to a specified position. The default data range is -1200 to 1200. The range may change after running the Lens Calibration function, which determines the full range allowed by the hardware. SUBCODE DESCRIPTION OF USE Adjust the lens focus offset to a...
Page 39
J Series Serial Commands Technical Reference Information39 of 90020-100796-01 Rev. 1 (10-2011) (FLE) Frame Lock Enable con’t EXAMPLES: (FLE 0) - Free Run output. (FLE 1) - Enables frame lock. (FLE ?) - Get frame lock enabled status. (FLW) SERIAL FLOW CONTROL CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Advanced DESCRIPTION Set the flow control for a serial communications port. SUBCODE PRTA DESCRIPTION OF USE Set the mode on port A (RS232 IN). PRTB Set the mode on port B...
Page 40
40 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (FRD) FRAME DELAY CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Delays the output signal timing relative to the input signal timing by a fraction of a frame, and up to several frames. The minimum latency can vary based on the amount of scaling applied to the image. When using key- stone or warping, an additional latency is required, depending on the amount of...