— 29 — INIT Copyright(C)2004 CASIO COMPUTER CO.,LTD. C All rights reserved. ROM VERxxxxxx xxxx 789 CREATExxxx-xx-xx xx:xx QT-6000 Versionx.xx456 APL VER.xxxxxx xxxx 123 0 OK Init Sw 7. DIAGNOSTIC OPERATION 7-1. To start the diagnostic program (1) Turn the power off. (2) Turn the power on while pressing the INIT switch. (3) Release the switch when the display shown below appears. * Operation is not guaranteed if the switch is released before the display appears. (4) Enter 99990000 and then [OK]. (5) LCD calibration test starts automatically. Refer to [ 12 ] LCD calibration test for the operation details. 7-2. Notes for the DIAG •Make sure the printer used to print out test results is set to a baud rate of 9600 bps and is connected to COM4. •Perform testing by connecting HHS-15 to COM2. •Always make sure to connect REMOTE DISP to COM3. •When desiring to conduct a test for an unlimited number of times, enter a value other than 0 in accordance with the explanation for each test. Tests are performed for an unlimited number of times when a value of 1 through 9 is entered for the commend used to specify the number of times testing is performed in the operating procedure on each page. However, this function allows a test to only be performed once or for an unlimited number times. [Procedure and Display for Operator-Evaluated Tests] •In operator-evaluated tests, the results for that test are determined according to the OK and NG keys after the following display appears. [OK] key: Register 1 [NG] key: Register 9 •A display that excludes the following display is shown for the LCD display of each test. | Please Hit Key OK-> 1 NG-> 9 | [Other] * ESC printout and display contents for forced termination of a test by ESC are as shown below. This display and printout are omitted in each test. | ESC | * That following printing of test results is omitted.
— 30 — 7-3. DIAG command input system Input a command according to the following code.X XXXXXnagd XXXXXX : additional action n : number of times a : action g : group d : device number 7-4. Status Display With the EX820, the following display is displayed on the LCD (SVGA). (In this DIAG, the display area is divided into a display for register entry and a display of DIAG results and so forth. ESC CLR 789 456 123 0 ST DALLAS DRW1 CLOSEMENU SHEET 1 DRW2 CLOSE0000 [Functions] Status is displayed for those devices having status information. The devices and status displayed are as shown below. Device Status Information (Displayed Information) Dallas key Dallas key no. Dallas key 2 Dallas key no. Drawer Open/close status MAC address MAC address CF Insertion status DISP ON/OFF switch Switch status TEMP Poxwer supply A/D conversion value * Display only updated when DISP ON/OFF switch is ON DALLAS DRW1 CLOSE MAC ADRS XX-XX-XX-XX-XX-XX CF INSERT DISP ON/OFF ON TEMP 20 Diag Ver : XXXXXX XXXXDRW2 CLOSE0000 1234 Status information is displayed continuously (in ordinary characters). However, when performing a test, the status at completion of a test is displayed following completion of that test. Register: Characters enlarged 1.5 times (max. 10 digits) Counter display [LCD Display] * Addition of TEMP information and DISP ON/OFF status The TEMP status is acquired preferentially when the DISP ON/OFF switch is ON. When measuring other status information or when starting each test mode, always make sure to begin after switching off the DISP ON/OFF switch.
— 31 — No Device to be checked Operation Note Page 1 Batch test 1 2 Test Device : RAM, FLASH, Display, 32 Print, Time, Drawer 2 Batch test 2 3 Test Device : Display, Back light 32 3 RAM WRITE/READ test n011 33 4 RAM READ only test n111 33 5 FLASH Check SUM test n512 34 6FLASH CLEAR/WRITE/READ testn612 34 7 CF-CARD WRITE/READ test pn013 35 8 CF-CARD READ only test pn113 35 9 CF-CARD CLEAR test pn213 36 10CF-CARD CLEAR&WRITE/READ testpn313 36 11 LCD test n021 37 12 LCD calibration test 221 38 13 Back light OFF test 121 38 14 Remote Cust DISP test bn023 39 15 External printer print test x1x2x3n03d 40 16 RS232C PORT test xn04d 41 17 RS232C PORT batch test 40 42 18 Ethernet test m0a51 43 19 MAC Address SET x0951 44 20 Wireless LAN test m0a52 45 21 Time settingx1x2x3x4x5x60a7046 22 Time display 70 46 23 Drawer open test xn091 46 24 Buzzer test n092 47 25 OBR test 95 47 26 MCR test 96 48 27 Sound playback test axn097 49 28 Sound recording test 98 50 29 Charging test 99 50 7-5. Check item The following test can be checked in the diagnostic test.
— 32 — 7-6. Operation of each test [ 1 ] Batch test 1 [Function] RAM test, FLASH test, display test, test print, time setting and drawer open test are performed continuously. Make sure to connect the printer to COM4. [Operation] Refer to the page for the details of the following tests. Operation : 2 ST The following tests are performed automatically. (1) RAM test : WRITE/READ all block test (2) FLASH : Check SUM test (3) Test print (4) Times setting : Set the following data. Arranged data : 2001 December 31, 23:59’30 (5) Drawer open : Opens all drawer. Enters the wait mode for the input of [OK] or [NG] by the operator after drawer open. (6) Receipt issuance [LCD] *When normally printed BATC H 2 RAM WR OK FLASH CHK SUM OK BBBBBBBBBBBBBBBBBBBB *8,888,88 DATE 01/12/31 TIME 23:59-30 DRW ALL OK END 2 Print Test [Print] *When normally printed BATC H 2 RAM WR OK FLASH CHK SUM OK DATE 01/12/31 TIME 23:59-30 Please Hit Key OK->1 NG->9 DRW ALL OK END 2 [Print] *When normally printed [ 2 ] Batch test 2 [Function] LCD display test and backlight test are performed continuously. [Operation] Refer to the page for the details of the following tests. Operation : 3 ST The following tests are performed automatically. (1) LCD test : Enters the wait mode for the input of [OK] or [NG] by the operator after the test. OK = 1, NG = 9 (2) Backlight OFF test : Turns the backlight off. Enters the wait mode for the input of [OK] or [NG] by the operator after the backlight turns off. *Since the backlight is turned off, Please Hit Key… cannot be seen. OK = 1, NG = 9 (3) Receipt issuance [LCD] *When normally printed BATCH 3 Please Hit Key OK->1 NG->9 LCD OK Please Hit Key OK->1 NG->9 BACK LIGHT OK END 3 Waiting for the input of [OK] or [NG] for the LCD test. Waiting for the input of [OK] or [NG] for the backlight. * When this appears, the backlight is turned off. BATC H 3 LCD OK BACK LIGHT OK END 3
— 33 — [ 3 ] RAM WRITE/READ test [Function] WRITE/READ test for RAM is performed. A counter is displayed for RAM test as follows. [Operation] Operation : n 0 1 1 ST n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] RAM n011 RAM WR OK END n011 [PRINT]NOTE: Prints the address of the error in case the test ended with an error. Prints the address of the error in case the test ended with an error. RAM n011 RAM WR NG END n011 [ 4 ] RAM READ ONLY test [Function] READ ONLY test for RAM is performed Note that WRITE test (n011) must be performed right before this test. [Operation] Operation : n 1 1 1 ST n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] RAM n111 RAM RD OK END n111 RAM n111 RAM RD OK END n111 NOTE: Prints the address of the error in case the test ended with an error. Prints the address of the error in case the test ended with an error. [PRINT]
— 34 — [ 5 ] FLASH Check SUM test [Function] This test will check SUM test for FLASH is performed. [Operation] Operation : n 5 1 2 ST n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] [PRINT] FLASH 512 FLASH CHK SUM OK END 512 FLASH 512 FLASH CHK SUM OK END 512 [ 6 ] FLASH CLEAR WRITE/READ test [Function] The CLEAR & WRITE/READ test for FLASH is performed. After deleting the memory by CLEAR, WRITE/READ test is performed. Note: since this test cannot backup the program, you need to perform IPL again after the test. When the memory in the FLASH memory is cleared (by the CLEAR test), the program is cleared also. [Operation] Operation : n 6 1 2 ST n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] NG and the address are displayed if WRITE cannot be done normally. NG and the address are printed if WRITE cannot be done normally. [PRINT]FLASH 612 FLASH WR ERASE PGM OK END 612 FLASH 612 FLASH WR ERASE PGM OK END 612
— 35 — [ 7 ] CF-CARD WRITE/READ test [Function] This test will check the write/read test (connection test) for CF-CARD. Perform the CF-CARD clear test, before start of this test. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 0 1 3 ST p : designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] NG and the address are displayed if WRITE cannot be done normally. [PRINT] CF-CARD pn013 CF WR OK END pn013 CF pn013 CF WR OK END pn013NG and the address are printed if WRITE cannot be done normally. [ 8 ] CF-CARD READ ONLY test [Function] This test will check the read only test for CF-CARD. Perform the CF-CARD write test, before start of this test. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 1 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] NG and the address are displayed if READ cannot be done normally. NG and the address are printed if WRITE cannot be done normally.CF-CARD pn113 CF RD OK END pn113 CF-CARD pn113 CF RD OK END pn113 [PRINT]
— 36 — [ 9 ] CF-CARD CLEAR test [Function] This test will check the clear test for CF-CARD. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 2 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] NG and the address are displayed if CLEAR cannot be done normally. NG and the address are printed if WRITE cannot be done normally.CF-CARD pn213 CF CLR OK END pn213 CF-CARD pn213 CF CLR OK END pn213 [PRINT] [ 10 ] CF-CARD CLEAR WRITE/READ test [Function] The CLEAR & WRITE/READ test for CF-CARD is performed. After deleting the memory by CLEAR, WRITE/READ test (connection test) is performed. Note that this test does not ensure the data inside the CF-CARD as well as its performance. [Operation] Operation : p n 3 1 3 ST p: designates PCMCIA SLOT 0 = CF 1 = PCMCIA n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] NG and the address are displayed if WRITE cannot be done normally. [PRINT] CF-CARD pn313 CF CLR&WR OK END pn313 CF-CARD pn313 CF CLR&WR OK END pn313NG and the address are printed if WRITE cannot be done normally.
— 37 — [ 11 ] LCD test [Function] This test will check the LCD display. In case of one time check only, the test can be ended by the judgment (OK or NG) of the operator. The display can be switched by the touch of the panel. The display will not change to the next one unless the panel is touched. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. OK = 1, NG = 9 Operation : n 0 2 1 ST n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press ESC key) [LCD] Green BlueReverse check Red White Black Touch any place in the panel.Touch any place in the panel.Touch any place in the panel.Touch any place in the panel.Touch any place in the panel.Touch any place in the panel. Check (black and white) Shows the following colors and patterns in the display in the order of black, white, red, green, blue, check and reverse check. Returns to the normal display after the test, and waits for the input of [OK] or [NG] by the operator (in case of one time check). In case of continuous check, the test is ended manually upon the input of [ESC] key. LCD n021 LCD OK END n021 [PRINT] LCD n021 LCD OK END n021
— 38 — [ 12 ] LCD calibration test [Function] This will test the calibration of the LCD (touch panel). * Perform the calibration in the diagnostic mode even when the product is in the market. Make sure to backup the register data when necessary. [Operation] A cross appears at the following four coordinates in the panel one by one. When a cross at a certain coordinate is touched, the next coordinate will show another cross there. (X,Y) = (100,100), (100,500), (700,100), (700,500) Operation : 2 2 1 ST If X4 or Y4 data goes out of the following tolerance, the test will be NG. Please test again. X4: 700±12 Y4: 500±12 [LCD] TOUCH START 221 (X1,Y1) : (XXX,XXX) (X2,Y2) : (XXX,XXX) (X3,Y3) : (XXX,XXX) (X4,Y4) : (XXX,XXX) END 221Displays data 1 for calibration Displays data 2 for calibration Displays data 3 for calibration Displays the position of the forth coordinate (performs calibration) How to skip the calibration test. (LCD) Enter the Caribration mode Push Disp on/off key Skip the Caribration mode Touch the panel To perform the caribration test : Push disp on/off key To skip the caribration test : Touch the panel [ 13 ] LCD Backlight OFF test [Function] This is a test for the LCD backlight. The test ends upon judgment of the operator between [OK] and [NG]. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. OK = 1, NG = 9 Operation : 1 2 1 ST [LCD] [PRINT] BACK LIGHT 121 BACK LIGHT OK END 121BACK LIGHT 121 BACK LIGHT OK END 121 [PRINT] TOUCH START 221 (X1,Y1) : (XXX,XXX) (X2,Y2) : (XXX,XXX) (X3,Y3) : (XXX,XXX) (X4,Y4) : (XXX,XXX) END 221