63 The consumer may follow the information provided on www.MyInfinity.carrier.comto register their system. This must be done BEFORE you attempt to access the system through www.HVACpartners.com. If you or the consumer have problems, contact 1 --800 --CARRIER for support.
64 8. Appendix A -- Wiring Diagrams A B C D A B C D User Interface Green - Data A Yellow - Data B White - COM Red - 24VAC OAT Optional Remote Room Sensor HUM COM 24VHumidifier ConnectionS2 S1 A B C D ABCD Connections Communicating AC or H P* Green Yellow White Red OAT Sensor (Optional) Variable-Speed Furnace/ Fan Coil *NOTE: Some outdoor units do not require the “C” and “D” connections. See outdoor unit Installation Instructions. A12353 Universal Four--Wire Connection
65 A B C D A B C D C Y ABCD Connection User Interface 1-Spd. Non-Communicating AC Green - Data A Yellow - Data B White - COM Red - 24VAC Optional Remote Room Sensor HUM COM 24VHumidifier Connection Y/Y2 S2 S1 OATOAT Sensor Variable-Speed Furnace/Fan Coil A12354 Connection Diagram for Furnace or FE Fan Coil with 1-- Stage Air Conditioning
66 A B C D A B C D ABCD Connection User Interface 1-Spd. Non-communicating HP Green - Data A Yellow - Data B White - COM Red - 24VAC Optional Remote Room Sensor HUM CHumidifier Connection Y S2 S1 W2 YO C R O R W OAT OAT Sensor Variable-Speed Fan Coil G A12355 Connection Diagram for FE Fan Coil with Non--communication 1--Stage Heat Pump
67 A B C D Zone Control User Interface & Smart Sensor(s) Green Yellow White Red OAT HUM COM 24VHumidifier Connection A B C D OAT Sensor (Optional) ABCDABCD Damper Control module ABCD Indoor UnitCommunicating AC or HP A04018 Zoning Connection for Communicating Indoor Unit with 2--Stage Communicating Outdoor Unit
68 A B C D Zone Control User Interface & Smart Sensor(s) Green Yellow White Red OAT HUM COM 24VHumidifier Connection OAT Sensor ABCDABCD Damper Control module ABCD Indoor Unit C Y 1-Stage AC. Y/Y2 A04019 Zoning Connection Diagram for Furnace or FE Fan Coil with Non-- Communicating 1 -- Stage Air Conditioning
69 A B C D Zone Control User Interface & Smart Sensor(s) Green Yellow White Red ABCDABCD Damper Control module ABCD Variable-Speed Fan Coil 1-Spd. HPHUM C Y W2 YO C ROR W OAT OAT Sensor Humidifier Connection G A07149 Zoning Connection diagram for FE Fan Coil with Non-- communicating 1 -- Stage Heat Pump
70 R G FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation
71 R G FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown
Infinity and HYBRIDHEAT are trademarks or registered trademarks of Carrier Corporation in the United States and other countries. Other brands and product names are trademarks of their respective holders. Copyright 2012 Carrier Corp.S7310 W. Morris St.SIndianapolis, IN 46231 Edition Date: 07/12 997-011280-3-R Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.Replaces: SYSTXCCITW --- 02SI Catalog No: SYSTXCCITW --- 03SI