Page 21
13 A12213 NOTE: Once the Infinity Touch Control is secured to wall with the backplate assembly (snapped together), care must be taken not to bend or break the interlocking tabs when removing. 4.6. Humidifier Connections A 24VAC bypass or fan powered humidifier may be installed. NOTE: Do NOT use a traditional humidistat to control humidifier operation. If a humidifier is installed, let the Infinity Touch Control operate humidifier. 4.6.1. Bypass Humidifier A bypass humidifier should be wired directly to...
Page 22
14 automatically energize the HUM output during a call for humidification. The N.O. relay contacts will be used to energize the humidifier. See fan powered humidifier installation instructions for more details. 5. Commissioning This section addresses initial power up (or commissioning) of a new Infinityr Touch Control. The control will communicate and identify all components in the InfinityrSystem. The following is a typical example for a communicating variable --speed furnace / fan coil with a 2 --stage...
Page 23
15 A12178 5.2. Searching for Outdoor Unit The Infinity Touch Control will then proceed to communicate with the outdoor unit by displaying “Searching for outdoor unit”. NOTE: If the outdoor unit cannot be found, the control will display “Outdoor unit not found”. SSelect the appropriate unit installed; then, touchNEXT. dAC1Stage– 1 --stage air conditioner dAC2Stage– 2 --stage air conditioner dHP1Stage– 1 --stage heat pump dHP2Stage– 2 --stage heat pump dNone– No outdoor unit installed SThe installer will...
Page 24
16 A12183 5.3. Indoor Evaporator Selection If a furnace is installed with a variable capacity heat pump, a screen will appear to select the installed indoor evaporator coil. This selection is used to adequately calculate the refrigerant charge required while in the heat pump charging screens under the Heat Pump Checkout menu (See page 44). Select “other” for non --Carrier evaporators. 5.4. Electric Heater Selection If the indoor equipment is a fan coil, the control will display “Searching for heater”...
Page 25
17 A12184 5.4.1. Hydronic Heat Application The Infinity Touch Control supports 2 types of Hydronic Heat applications: 1. Hot water coil in combination with an FE fan coil and heat pump, or hot water coil as sole heat source with an FE fan coil. 2. Non --zoned FE fan coil combined with radiant hot water heat. In either application, a Hydronic Heat kit should be installed in place of an electric heater. See FE fan coil Product Data for accessory part number. The system will self--identify that hydronic...
Page 26
18 A12185 5.6. Filter Type Selection The installer will next be prompted to select the air filter type installed with the Infinity System. After the selection is made, touchNEXT. SAir Filter: 1 --in. to 4 --in. media filter SEAC: high voltage electronic air cleaner SAir Purifier: Infinityror PerformancetAir Purifier 5.7. Humidifier Installation Next, the installer will be prompted to select whether a humidifier is installed in the system. SelectYESorNO, then touchNEXT. 5.8. Ultraviolet Lights...
Page 27
19 that particular screen and make changes. When everything is OK, touchNEXTto continue. A12144 5.10. Static Pressure Check The static pressure check screen will appear next. The system will perform a static pressure check. This process will take about 1 --1/2 minutes to complete. When completed, a screen will appear displaying the static pressure (in inches) across the equipment at the expected highest delivered airflow. If the blower RPM is greater than 1200, then a warning will appear, but equipment...
Page 28
20 approximately one minute per zone. The duct assessment will override a call for heat or cool. A duct assessment will automatically occur each day at a user selectable time. The factory default time is 1:00 p.m. but, may be changed by entering the Zoning Setup menu (see pages 36 -- 37). If there is an active call for heating or cooling, the system will wait until the call is satisfied before it performs the duct assessment. The system will first open all zones and drive the blower to 175 CFM/ton of...
Page 29
21 6. Service Menu The Service menus contain a set of vital information. This information enables the installer or service person to view a summary of what has been installed, etc. This information is not covered in the Owner’s Manual. To enter service menus, touch menu, then touch and hold theSERVICEicon for at least ten seconds. The following screens are available in installation and service. To return to the previous screen, touchBACK. To exit the Service menus, touch DONE. A12145 6.1. Equipment...
Page 30
22 A12144 6.2. Installation TouchINSTALLATIONto perform the start --up process in order to learn all equipment in system. Press right side button to initiate the process. TouchNEXTto begin the process. A12146 6.3. Set up 6.3.1. Thermostat First touchSETUP, then touchTHERMOSTATto set up the parameters for the InfinityrTouch Control.