Home > Carrier > Computer Equipment > Carrier Microlink 2 Manual

Carrier Microlink 2 Manual

Here you can view all the pages of manual Carrier Microlink 2 Manual. The Carrier manuals for Computer Equipment are available online for free. You can easily download all the documents as PDF.

Page 21

3-4 62-02575-07
To modify the CONFIG.SYS file, the following entries must be in the CONFIG.SYS file to execute the DataView
program:
i. DEVICE = \DOS\HIMEM.SYS
ii. DEVICE = \DOS\EMM386.EXE X=C800--CFFF I=DOOO--DFFF V
iii. DEVICE = \DOS\POWER.EXE
iv. DEVICE = \DOS\INTERLINK.EXE
v. DOS = HIGH, UMB
vi. FILES = 40
vii. BUFFERS = 30
The other entries should have “REM” entered before each entry. This will retain the information in the file, but the
entry will not be executed. For example; the entry, “DEVICE =...

Page 22

3-5 62-02575-07
Throughout the program two major types of menus are used:
1. Check boxes allow the selection of all menu items that apply and look like this:
[] Graph
[X] Tabular Data
[ ] Raw Events
2. Radio buttons allow the selection of only one item and look like this:
(*) Metric Units
( ) Standard Units
To select or deselect an item in either of these two menu’s, use the UP and DOWN arrow keys to highlight the selection
and press  to select.
TOPIC 4 RAW FILE CONVERSION
The raw file conversion...

Page 23

3-6 62-02575-07
 Go -- Allows the user to start the RAW to DCX file conversion. The following steps are processed:
1. The Raw File Conversion screen is cleared.
2. The File Processing popup is displayed.
3. Each file in the current directory is checked to verify if it is a RAW formatted file. If not, it skips this file and checks
the next file.
4. Each RAW formatted file found within the current directory is converted to the DCX format and stored in the work-
ing directory with the same filename and the...

Page 24

3-7 62-02575-07 TOPIC 6 MAIN MENU SCREEN
This section describes the features available from the main menu. The following screen will be displayed when the
program starts up.
The following is a summary of the options available to the user:
 Interrogate -- This will allow the user to extract the data from the Recorder. The available interrogation methods
are: By Trip, By Date, Last 30 Days, and All Data.
 DataReader -- This will allow the user to transfer copied data from the DataReader to the computer,...

Page 25

3-8 62-02575-07 TOPIC 7 INTERROGATION MENU
This section describes how to retrieve data from the recorder. The following screen is displayed when this option is
selected.
The following is a summary of the options available in Interrogation.
 By Trip -- All data logged from the Trip Start selected until the next Trip Start (or the last date in the recorder) will
be downloaded.
 By Date -- All data logged between two user specified dates will be downloaded.
 Last 30 Days -- All data logged in the last 30...

Page 26

3-9 62-02575-07 TOPIC 8 DATAREADER
The DataReader Interface program communicates with the DataReader. It provides the user with the ability to view the
files on the DataReader, read the files from the DataReader and store the data into the DCX file format on the users
computer. The program also allows the user to erase all the files on the DataReader. The following screen is displayed
when this option is chosen.
The following is a summary of the options available in DataReader Interface Utility.
 Working...

Page 27

3-10 62-02575-07 TOPIC 9 SYSTEM TOOLS
The system tools screen provides the user with the ability to view and/or modify the recorder and controller data
values. The following screen is displayed when this option is chosen.
The following is a summary of the options available in System Tools.
 Controller Utilities -- This will allow the user to set the controller configuration, enter a new container ID, change
how the controller operates via the selectable parameters, change the set point and view the...

Page 28

3-11 62-02575-07 TOPIC 10 CONTROLLER UTILITIES
This section describes the features available on the controller utilities.
View/Change Container ID
This will allow the user to view and modify the current container ID read from the controller. Upon changing the
container ID, the new ID is sent to the controller, the DataView program informs the user that the container ID was
successfully sent, and returns the user to the System Tools Screen. The following screen is displayed when this option
is chosen....

Page 29

3-12 62-02575-07 Control Setpoint
This will allow the user to view and modify the current control setpoint being read from the controller. Upon changing
the setpoint, the new setpoint value is sent to the controller, the DataView program informs the user that the setpoint
was successfully sent, and returns the user to the System Tools Screen. The following screen is displayed when this
option is chosen.
Upon pressing  to Cancel, the setpoint is canceled and the user is returned to the System Tools Screen. 

Page 30

3-13 62-02575-07 Control Parameters
The following screen is displayed for the user to view and modify the current settings of the controller user selectable
parameters.
The following is a summary of the options available in Controller Parameters.
 Defrost Interval -- Allows the user to view and modify the automatic defrost interval.
 Units -- Allows the user to view and modify the temperature units which are used when displaying controller
temperature sensors.
 Shutdown Mode -- Allows the user to view...
Start reading Carrier Microlink 2 Manual
All Carrier manuals