Page 31
3-14 62-02575-07 TOPIC 11 CONTROLLER CONFIGURATION The Controller Configuration allows the user to view and modify the current controller configuration. The current model configuration, the selectable configuration variables, and the fixed configuration variables are listed. The user can select another model configuration and modify the selectable configuration variables. The following screen is displayed when this option is chosen. The following is a summary of the options available in Controller...
Page 32
3-15 62-02575-07 Fixed Configuration Variables Allows the user to view the fixed configuration variables for the selected configuration model. These variables describe the refrigeration unit and cannot be modified by the user. The following screen is displayed when this option is chosen. The following is a summary of the options available in Fixed Configuration Variables. Configuration Available -- This lists the models available for the controller. Fixed Configuration Variables -- This lists the fixed...
Page 33
3-16 62-02575-07 Custom Controller Configuration Allows the user to change the selectable configuration variables and save those values into a new configuration model. The following screen is displayed when this option is chosen. The following is a summary of the options available in Custom Controller Configuration. Dehumidification -- Allows the user to configure or not configure the controller with a dehumidification device. Defrost Interval Save -- Allows the user to save or not save the defrost...
Page 34
3-17 62-02575-07 Help -- Displays the help screen. Cancel -- Cancels the changes to the custom controller configuration and returns the user to the Controller Configuration Screen. TOPIC 12 RECORDER UTILITIES This section describes the features available on the recorder utilities menu. Trip Functions This feature will allow the user to initiate a Trip Start and enter specific Trip comments. The following screen is displayed when this option is chosen. The following is a summary of the options available...
Page 35
3-18 62-02575-07 Configuration This allows the user to modify the recorder configuration. For a full description of the configuration selections and illustrations of the applicable screens, refer to TOPIC 13.
Page 36
3-19 62-02575-07 Date And Time This allows the user to view and/or modify the recorder date and time. The computer time and date are displayed as an aid to the user. The following screen is displayed when this option is chosen. The recorder date is displayed in Greenwich Mean Time (GMT). The user enters the date and time, the date and time is sent to the recorder, the DataView program informs the user that the date and time was successfully sent, and returns the user to the System Tools Screen. Upon...
Page 37
3-20 62-02575-07 Update ISO Trip Header This allows the user to view and/or modify the data recorder ISO trip header. Each field has a maximum size of 13 characters. A maximum of 128 total characters are allowed. The date and time are initialized from the current date and time on the data recorder. The following screen is displayed when this option is chosen. The user enters the trip header fields, one at a time. Upon pressing the current field is accepted and the cursor is moved to the next field. Upon...
Page 38
3-21 62-02575-07 TOPIC 13 RECORDER CONFIGURATION The Recorder Configuration allows the user to view and modify the current recorder configuration. The Recorder Configuration screen shows all of the sensors installed to a unit and whether they are configured to be recorded. It also shows the recording interval. The following screen is displayed when this option is chosen. The following is a summary of the options available in Recorder Configuration. Recording Interval -- Allows the user to change the...
Page 39
3-22 62-02575-07 Standard Configuration This feature will allow the user to select a standard recorder configuration, set the alarms, set the sample type for the recorder sensors, set the sample size for the recorder sensors, and set the sample type for the controller sensors. The following screen is displayed when this option is chosen. The following is a summary of the options available in Standard Configuration. Standard Configuration -- Allows the user to select the configuration. When a...
Page 40
3-23 62-02575-07 Generic Configuration The Recorder Generic Configuration allows the user to view and modify the current recorder configuration. The Recorder Generic Configuration screen shows all of the sensors installed to a unit and whether they are configured to be recorded. It allows the user to modify the recording interval, recorder sensors, and controller sensors. The following screen is displayed when this option is chosen. The following is a summary of the options available in Recorder Generic...